Wire Cable Assemblies
28110A
The Belden 28110A is a UL Type TC (1277) power and control cable with three 12 AWG (7x20) bare copper conductors, PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, sunlight resistant, and suitable for direct burial. It is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
28137A
The Belden 28137A is a UL Type TC (1277) power and control cable with 30 conductors of 12 AWG (7x20) bare copper, PVC/nylon E2 insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF) at 90°C dry/wet, with a maximum current of 13.5 Amps per Conductor at 30ºC. It is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
28139A
The Belden 28139A is a UL Type TC (1277) 3-conductor power and control cable with 10 AWG (7x18) bare copper conductors, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER), 90 °C dry and wet, and is sunlight resistant and suitable for direct burial in power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
28140A
The Belden 28140A is a UL Type TC (1277) power and control cable with four 10 AWG (7x18) stranded bare copper conductors, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER), 90 °C dry and wet, and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
28143A
The Belden 28143A is a UL Type TC power and control cable with seven 10 AWG (7x18) bare copper conductors, PVC/nylon insulation, and a black PVC outer jacket. It is rated for 600 V, 90 °C dry/wet operation, and is suitable for indoor, outdoor, sunlight-resistant, direct burial, and Class 1 Division 2 hazardous location applications. The cable has no shield, includes a ripcord, and has a nominal overall diameter of 0.618 in (15.7 mm).
28150A
The Belden 28150A is a UL Type TC (1277) power and control cable rated for 600 V, with three 8 AWG bare copper conductors and one 10 AWG bare copper ground wire, PVC/nylon insulation, and a black PVC outer jacket. It is rated 90 °C dry and 90 °C wet, is sunlight resistant and suitable for direct burial, and is listed for Class 1 Division 2 hazardous locations. Suitable applications are power and control applications up to 600 V.
28156A
The Belden 28156A is a UL Type TC power and control cable with three 4 AWG bare copper conductors and one 8 AWG bare copper ground conductor, insulated with PVC/nylon and covered by a black PVC jacket with a ripcord. It is rated 600 V (TC-ER), 90 °C dry and wet, and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable is sunlight resistant and rated for direct burial.
28324A
The Belden 28324A is a 25-conductor, 16 AWG (7x24 bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF) for operation from -30°C to 90°C in wet/dry conditions, and is approved for indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial installations. Listed applications include power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
28328A
The 28328A is a Belden UL Type TC power and control cable with 10 conductors of 18 AWG (7x26) bare copper, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.442 in and is sunlight resistant and rated for direct burial.
28335A
The Belden 28335A is a 5-conductor, 18 AWG (7x26) bare copper power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with an operating temperature range of -30°C to 90°C wet/dry, and is suitable for power and control applications up to 600V and Class 1 Division 2 hazardous locations.
28341A
Belden 28341A is a 12-conductor power and control cable built with 16 AWG (7x24) bare copper conductors, PVC/nylon E2 insulation, and a black PVC outer jacket with ripcord. It is rated 600 V (TC-ER) and 150 V (NPLF), 90 °C dry/wet, and is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
29006
Belden 29006 is a 600 V ACIC power and control cable with twelve 16 AWG stranded bare copper conductors plus a bare copper ground wire. It uses cross-linked polyethylene insulation, a PVC inner jacket, aluminum interlocked armor, and a PVC outer jacket, and is suitable for indoor, outdoor, sunlight-resistant, and burial installations up to 600 V.
29008
Belden part 29008 is a TC-ACIC Canadian instrumentation cable rated for 600 V power and control applications. It contains 30 bare copper 16 AWG conductors plus one 16 AWG ground wire, with XLPE insulation, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated for indoor, outdoor, sunlight-resistant, and burial use from -40 °C to +90 °C.
29501
Belden 29501 is a 600/1000 V flexible motor supply cable built for variable frequency drive and AC motor systems. It has three 14 AWG tinned copper phase conductors with XLPE insulation, a 300% ground arrangement (insulated and uninsulated 14 AWG grounds), and an overall foil-plus-braid shield with a black PVC jacket. It is rated TC-ER WTTC and is suitable for Class 1 Division 2 hazardous locations, indoor/outdoor use, sunlight resistance, and direct burial.\n","key_specs":["Conductors: 3 x 14 AWG 41x30 tinned copper phase; 1 x 14 AWG insulated ground; 1 x 14 AWG uninsulated ground","Insulation: XLPE 0.046 in (1.2 mm); conductor nominal diameter 0.173 in (4.39 mm)","Shield: Tri-Laminate (Alum+Poly+Alum) tape 100% plus tinned copper braid 85% with 14 AWG drainwire","Jacket: black PVC 0.073 in (1.9 mm); overall cable diameter 0.604 in (15.3 mm)","Voltage rating: 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC), 1000 V (AWM I/II A/B)","Temperature: UL 90°C Dry, 90°C Wet; operating -40°C To +90°C; installation -40C","Current: 25 Amps per Conductor at 30ºC (per NEC)","Mechanical: max pull tension 347 lbs (157 kg); weight 224 lbs/1000ft (333 kg/km); bend radius 6.0 in (150 mm) stationary, 7.2 in (180 mm) installation"],"absolute_max_ratings":[],"pin_table":[],"marking_code":null,"applications":["Variable Frequency Drives (VFD)","AC Motor and Drive Systems","Class 1 Division 2 Hazardous Locations"]}
29505
Belden 29505 is a flexible 600/1000 V motor supply cable designed for variable frequency drives (VFD) and AC motor and drive systems. It contains three 6 AWG tinned copper conductors with XLPE insulation, one insulated 6 AWG PVC ground, four 12 AWG uninsulated tinned copper ground/drain wires, and an overall Beldfoil plus 85% tinned copper braid shield under a black PVC jacket. It is rated TC-ER and WTTC for 90°C dry/wet operation and is suitable for indoor, outdoor, sunlight-resistant, and direct burial installations.
29506
Belden 29506 is a flexible 600/1000 V motor supply cable designed for Variable Frequency Drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations. It contains three 4 AWG tinned copper conductors with XLPE insulation, an insulated 4 AWG ground, four uninsulated 10 AWG tinned copper ground/drain wires, an overall shielded construction, and a black PVC jacket rated 90 °C dry/wet. The cable complies with TC-ER, WTTC, UL flexible motor supply cable, AWM, CIC/TC, and RoHS/CE requirements.
29507
Belden 29507 is a flexible 600/1000 V TC-ER WTTC motor supply cable built with three 2 AWG tinned copper conductors, XLPE insulation, and a PVC-insulated ground wire. It includes four 8 AWG segmented tinned-copper ground/drain wires, an overall Beldfoil plus 87% tinned copper braid shield, and a black PVC jacket with ripcord. Rated for 90°C dry/wet operation (-40°C to +90°C), it is intended for variable frequency drives, AC motor and drive systems, and Class 1 Division 2 hazardous locations.
29530
Belden 29530 is a flexible 600/1000 V VFD motor supply cable with three 2/0 AWG tinned copper conductors, XLPE insulation, and a symmetrical segmented bare copper ground. It uses 100% dual helical bare copper tape shielding under a black PVC jacket with ripcord, rated 90 °C dry/wet for TC-ER, WTTC, and Class 1 Division 2 hazardous locations. It is intended for variable frequency drives and AC motor and drive systems.
29538
Belden 29538 is a 300% ground flexible VFD supply cable with three 10 AWG (105x30) tinned copper conductors and one 10 AWG tinned copper ground conductor, all insulated with XLPE. It has an overall Beldfoil tri-laminate tape shield at 100% coverage plus 85% tinned copper braid with a 10 AWG tinned copper drain wire, a black PVC jacket, and is rated for 2000 V TC-ER / 1000 V WTTC flexible motor supply use at 90 °C dry/wet. It is intended for variable frequency drives, AC motor and drive systems, and high voltage requirements.
29542
Belden part 29542 is a flexible 2000 V VFD motor supply cable with three 2 AWG (7x19x23) tinned copper conductors and one 2 AWG tinned copper ground, XLPE insulation, an overall Beldfoil tri-laminate (100%) plus tinned copper braid (85%) shield with three #8 tinned copper drains, and a black PVC jacket. It is rated 90°C dry/wet (UL), TC-ER and WTTC, sunlight resistant, direct burial and oil resistant, and is intended for variable frequency drives, AC motor and drive systems, and high voltage requirements. Nominal overall diameter is 1.361 in (34.57 mm).