The 28328A is a Belden UL Type TC power and control cable with 10 conductors of 18 AWG (7x26) bare copper, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.442 in and is sunlight resistant and rated for direct burial.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

28328A Key Specifications

Max Current
24 Amps per Conductor at 30ºC
Voltage Rating
600 V (TC-ER), 150 V (NPLF)
Temperature Rating
90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C
Bend Radius
Stationary Min: 1.768 in (44.91 mm); Installation Min: 2.21 in
Conductors
10 conductors, 18 AWG (7x26) Bare Copper
Max Pull Tension
220 lbs (100 kg)
Nom. Conductor DCR
6.7 Ohm/1000ft
Overall Cable Diameter
0.442 in

Characteristics (datasheet)

Conductors
10 conductors, 18 AWG (7x26) Bare Copper
Voltage Rating
600 V (TC-ER), 150 V (NPLF)
Max Current
24 Amps per Conductor at 30ºC
Nom. Conductor DCR
6.7 Ohm/1000ft
Temperature Rating
90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C
Overall Cable Diameter
0.442 in
Max Pull Tension
220 lbs (100 kg)
Bend Radius
Stationary Min: 1.768 in (44.91 mm); Installation Min: 2.21 in

28328A Applications

  • Power and Control Applications up to 600V
  • Class 1 Division 2 Hazardous Locations

Other Belden parts

  • 6362 — The Belden 6362 is a communication and control cable consisting of 2 pairs of 24...
  • 6075 — The Belden 6075 is a Teck90 600V cable designed for CEC power and control applic...
  • 8669 — The Belden 8669 is a tinned copper (TC) braid conductor of 8.9 AWG (336x34) desi...
  • 3104A — The Belden 3104A is a shielded, 3-conductor 12 AWG bare copper cable with PVC-Ny...
  • 78216 — The Belden 78216 (Alpha Wire P/N 78216) is a multi-pair cable featuring 6 pairs...
  • 7928A — The Belden 7928A is a DataTuff Cat 5e industrial Ethernet cable featuring four b...
  • 27331AS — The Belden 27331AS is a UL Type TC power and control cable with three 16 AWG (7x...
  • 934066104 — HIRSCHMANN TEST AND MEASUREMENT 934066104 Test Lead, 4mm Banana Plug to 4mm...

More Bulk Wire Cable

  • 45114 — Belden part 45114 is an XTRAGUARD 4 cable with four 24 AWG (7x32) tinned copper...
  • 77135 — The Belden 77135 is a 4-conductor 16 AWG tinned copper ECOCABLE with mPPE insula...
  • 78182 — The Belden 78182 is a shielded ECOCABLE featuring two pairs of 22 AWG tinned cop...
  • 30804 — The Belden 30804 is a 4 AWG (105x24) stranded tinned copper lead wire with silic...
  • 21585 — Belden 21585 is a CSA Type TC-CIC tray cable rated 600 V with 37 conductors plus...
  • 9623 — The Belden 9623 is a 5-conductor electronic cable made of 14 AWG (19x27) tinned...
  • 7122W — The 7122W is a MachFlex™ high-flex cable featuring 2+1 conductors of 16 AWG bare...
  • 9989 — The Belden 9989 is a low-temperature plastic lead wire featuring a 14 AWG strand...

28328A FAQ

What is 28328A?

28328A is a Bulk Wire Cable from Belden. The 28328A is a Belden UL Type TC power and control cable with 10 conductors of 18 AWG (7x26) bare copper, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.442 in and is sunlight resistant and rated for direct burial.

Who manufactures 28328A?

28328A is manufactured by Belden.

Where can I download the 28328A datasheet PDF?

The 28328A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 28328A specifications

AI Powered

Click to ask a quick question:

Parameters

Bend RadiusStationary Min: 1.768 in (44.91 mm); Installation Min: 2.21 in
Conductors10 conductors, 18 AWG (7x26) Bare Copper
Max Current24 Amps per Conductor at 30ºC
Max Pull Tension220 lbs (100 kg)
Nom. Conductor DCR6.7 Ohm/1000ft
Overall Cable Diameter0.442 in
Temperature Rating90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C
Voltage Rating600 V (TC-ER), 150 V (NPLF)