28328A Datasheet
The 28328A is a Belden UL Type TC power and control cable with 10 conductors of 18 AWG (7x26) bare copper, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.442 in and is sunlight resistant and rated for direct burial.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
28328A Key Specifications
- Max Current
- 24 Amps per Conductor at 30ºC
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature Rating
- 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C
- Bend Radius
- Stationary Min: 1.768 in (44.91 mm); Installation Min: 2.21 in
- Conductors
- 10 conductors, 18 AWG (7x26) Bare Copper
- Max Pull Tension
- 220 lbs (100 kg)
- Nom. Conductor DCR
- 6.7 Ohm/1000ft
- Overall Cable Diameter
- 0.442 in
Characteristics (datasheet)
- Conductors
- 10 conductors, 18 AWG (7x26) Bare Copper
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Max Current
- 24 Amps per Conductor at 30ºC
- Nom. Conductor DCR
- 6.7 Ohm/1000ft
- Temperature Rating
- 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C
- Overall Cable Diameter
- 0.442 in
- Max Pull Tension
- 220 lbs (100 kg)
- Bend Radius
- Stationary Min: 1.768 in (44.91 mm); Installation Min: 2.21 in
28328A Applications
- Power and Control Applications up to 600V
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 6362 — The Belden 6362 is a communication and control cable consisting of 2 pairs of 24...
- 6075 — The Belden 6075 is a Teck90 600V cable designed for CEC power and control applic...
- 8669 — The Belden 8669 is a tinned copper (TC) braid conductor of 8.9 AWG (336x34) desi...
- 3104A — The Belden 3104A is a shielded, 3-conductor 12 AWG bare copper cable with PVC-Ny...
- 78216 — The Belden 78216 (Alpha Wire P/N 78216) is a multi-pair cable featuring 6 pairs...
- 7928A — The Belden 7928A is a DataTuff Cat 5e industrial Ethernet cable featuring four b...
- 27331AS — The Belden 27331AS is a UL Type TC power and control cable with three 16 AWG (7x...
- 934066104 — HIRSCHMANN TEST AND MEASUREMENT 934066104 Test Lead, 4mm Banana Plug to 4mm...
More Bulk Wire Cable
- 45114 — Belden part 45114 is an XTRAGUARD 4 cable with four 24 AWG (7x32) tinned copper...
- 77135 — The Belden 77135 is a 4-conductor 16 AWG tinned copper ECOCABLE with mPPE insula...
- 78182 — The Belden 78182 is a shielded ECOCABLE featuring two pairs of 22 AWG tinned cop...
- 30804 — The Belden 30804 is a 4 AWG (105x24) stranded tinned copper lead wire with silic...
- 21585 — Belden 21585 is a CSA Type TC-CIC tray cable rated 600 V with 37 conductors plus...
- 9623 — The Belden 9623 is a 5-conductor electronic cable made of 14 AWG (19x27) tinned...
- 7122W — The 7122W is a MachFlex™ high-flex cable featuring 2+1 conductors of 16 AWG bare...
- 9989 — The Belden 9989 is a low-temperature plastic lead wire featuring a 14 AWG strand...
28328A FAQ
What is 28328A?
28328A is a Bulk Wire Cable from Belden. The 28328A is a Belden UL Type TC power and control cable with 10 conductors of 18 AWG (7x26) bare copper, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.442 in and is sunlight resistant and rated for direct burial.
Who manufactures 28328A?
28328A is manufactured by Belden.
Where can I download the 28328A datasheet PDF?
The 28328A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 28328A specifications
Click to ask a quick question:
Parameters
| Bend Radius | Stationary Min: 1.768 in (44.91 mm); Installation Min: 2.21 in |
| Conductors | 10 conductors, 18 AWG (7x26) Bare Copper |
| Max Current | 24 Amps per Conductor at 30ºC |
| Max Pull Tension | 220 lbs (100 kg) |
| Nom. Conductor DCR | 6.7 Ohm/1000ft |
| Overall Cable Diameter | 0.442 in |
| Temperature Rating | 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C |
| Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |