29008 Datasheet

BeldenBulk Wire Cable

Belden part 29008 is a TC-ACIC Canadian instrumentation cable rated for 600 V power and control applications. It contains 30 bare copper 16 AWG conductors plus one 16 AWG ground wire, with XLPE insulation, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated for indoor, outdoor, sunlight-resistant, and burial use from -40 °C to +90 °C.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

29008 Key Specifications

Max. Current per Conductor
10.8 Amps at 30 °C
Voltage Rating
600 V
Operating Temperature
-40 °C to +90 °C
Armor
AIA - Aluminum Interlock Armor, 0.034 in (0.86 mm)
Conductors
30 × 16 AWG (7x24) bare copper plus 1 × 16 AWG (7x24) bare copper ground wire
Insulation
XLPE/XLPO/XLP (Thermoset), 0.030 in (0.76 mm) nominal thickness
Max. Conductor DCR
4.2 Ohm/1000ft
Overall Cable Diameter
1.325 in

Characteristics (datasheet)

Voltage Rating
600 V
Conductors
30 × 16 AWG (7x24) bare copper plus 1 × 16 AWG (7x24) bare copper ground wire
Insulation
XLPE/XLPO/XLP (Thermoset), 0.030 in (0.76 mm) nominal thickness
Armor
AIA - Aluminum Interlock Armor, 0.034 in (0.86 mm)
Overall Cable Diameter
1.325 in
Operating Temperature
-40 °C to +90 °C
Max. Conductor DCR
4.2 Ohm/1000ft
Max. Current per Conductor
10.8 Amps at 30 °C

29008 Applications

  • Power and Control Applications up to 600V

Other Belden parts

  • 6634 — The Belden 6634 is a 4-conductor, 22 AWG tinned copper control cable with PVC ir...
  • 5008C — The Belden 5008C is an XTRAGUARD 1 cable with eight 22 AWG tinned copper conduct...
  • 80107 — The Belden 80107 (Alpha Wire P/N 80107) is a high-flexibility, 8-conductor cable...
  • 24501D — Belden 24501D is a Canadian TC-ACIC 600 V instrumentation cable with one 16 AWG...
  • 8073 — The Belden 8073 is a 14 AWG solid bare copper magnet wire with polyester/amide-i...
  • 76603TS — The Belden 76603TS is a MachFlex™ high-flexibility cable designed for continuous...
  • 1132C — The Belden 1132C is a 2-pair 18 AWG tinned copper communication and control cabl...
  • 6018C — The Belden 6018C is a communication and control cable consisting of 15 pairs of...

More Bulk Wire Cable

  • 28328A — The 28328A is a Belden UL Type TC power and control cable with 10 conductors of...
  • 5475C — The Belden 5475C is a multi-pair communication and control cable consisting of 5...
  • 9546 — The Belden 9546 is a computer EIA RS-232 cable consisting of 50 stranded tinned...
  • 30818 — Belden part 30818 is an 18 AWG (16x30) tinned copper lead wire with silicone rub...
  • 7408W — The 7408W is a MachFlex™ high-flex multi-conductor cable featuring 24 conductors...
  • 83609 — The Belden 83609 is a high-temperature plenum-rated (CMP) 9-conductor electronic...
  • 5301C — The 5301C is a multi-conductor shielded cable featuring seven 24 AWG tinned copp...
  • 6303UE — The Belden 6303UE is a plenum-rated security and sound cable (CMP) containing fi...

29008 FAQ

What is 29008?

29008 is a Bulk Wire Cable from Belden. Belden part 29008 is a TC-ACIC Canadian instrumentation cable rated for 600 V power and control applications. It contains 30 bare copper 16 AWG conductors plus one 16 AWG ground wire, with XLPE insulation, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated for indoor, outdoor, sunlight-resistant, and burial use from -40 °C to +90 °C.

Who manufactures 29008?

29008 is manufactured by Belden.

Where can I download the 29008 datasheet PDF?

The 29008 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 29008 specifications

AI Powered

Click to ask a quick question:

Parameters

ArmorAIA - Aluminum Interlock Armor, 0.034 in (0.86 mm)
Conductors30 × 16 AWG (7x24) bare copper plus 1 × 16 AWG (7x24) bare copper ground wire
InsulationXLPE/XLPO/XLP (Thermoset), 0.030 in (0.76 mm) nominal thickness
Max. Conductor DCR4.2 Ohm/1000ft
Max. Current per Conductor10.8 Amps at 30 °C
Operating Temperature-40 °C to +90 °C
Overall Cable Diameter1.325 in
Voltage Rating600 V