28110A Datasheet
The Belden 28110A is a UL Type TC (1277) power and control cable with three 12 AWG (7x20) bare copper conductors, PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, sunlight resistant, and suitable for direct burial. It is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
28110A Key Specifications
- Max. current
- 30 Amps per Conductor at 30ºC
- UL voltage rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature rating
- 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C
- Bulk cable weight
- 103 lbs/1000ft
- Conductors
- 3 x 12 AWG, 7x20 stranded bare copper
- Max. pull tension
- 260.4 lbs (118.1 kg)
- Minimum bend radius
- 1.52 in (38.6 mm) stationary; 1.9 in (48 mm) installation
- Nominal conductor DCR
- 1.68 Ohm/1000ft
Characteristics (datasheet)
- Conductors
- 3 x 12 AWG, 7x20 stranded bare copper
- Nominal conductor DCR
- 1.68 Ohm/1000ft
- Max. current
- 30 Amps per Conductor at 30ºC
- UL voltage rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature rating
- 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C
- Minimum bend radius
- 1.52 in (38.6 mm) stationary; 1.9 in (48 mm) installation
- Max. pull tension
- 260.4 lbs (118.1 kg)
- Bulk cable weight
- 103 lbs/1000ft
28110A Applications
- Power and Control Applications up to 600V
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 6311 — The Belden 6311 is a 40-conductor, 24 AWG tinned copper communication and contro...
- 45060 — Belden part 45060 is an XTRAGUARD 4 cable with 10 conductors of 20 AWG (7/28) ti...
- 9367 — The Belden 9367 is a high-performance instrumentation cable featuring one triad...
- 23542D — Belden 23542D is a Canadian TC-ACIC 300 V instrumentation cable containing 24 pa...
- 9769 — The Belden 9769 is an audio, control, and instrument cable featuring 17 individu...
- 25000UE — The Belden 25000UE is a CMR/riser-rated security and commercial audio cable with...
- 45386 — Belden 45386 is a 6-conductor, 18 AWG (16x30) stranded tinned copper cable with...
- 6065 — The Belden 6065 is a Teck90 600V cable featuring 12 bare copper conductors plus...
More Bulk Wire Cable
- 2414C — The 2414C is a 4-conductor, 20 AWG tinned copper communication and control cable...
- 8478 — The Belden 8478 is a portable cordage featuring two 18 AWG bare copper conductor...
- 5078C — The Belden 5078C is an XTRAGUARD 1, 8-conductor 16 AWG stranded tinned copper ca...
- 83004 — The Belden 83004 is a high-temperature plastic lead wire with a 24 AWG silver-pl...
- 50094LS — The Belden 50094LS is an RS-485 cable consisting of 4 pairs of 22 AWG stranded t...
- 1395 — The Belden 1395 is a single-conductor RWU90 cable rated for 1000V, featuring a b...
- 83506 — The Belden 83506 is a high-temperature plenum-rated (CMP) multi-conductor electr...
- 1329A — The 1329A is an eight-pair, 18 AWG stranded tinned copper conductor cable with p...
28110A FAQ
What is 28110A?
28110A is a Bulk Wire Cable from Belden. The Belden 28110A is a UL Type TC (1277) power and control cable with three 12 AWG (7x20) bare copper conductors, PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, sunlight resistant, and suitable for direct burial. It is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
Who manufactures 28110A?
28110A is manufactured by Belden.
Where can I download the 28110A datasheet PDF?
The 28110A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 28110A specifications
Click to ask a quick question:
Parameters
| Bulk cable weight | 103 lbs/1000ft |
| Conductors | 3 x 12 AWG, 7x20 stranded bare copper |
| Max. current | 30 Amps per Conductor at 30ºC |
| Max. pull tension | 260.4 lbs (118.1 kg) |
| Minimum bend radius | 1.52 in (38.6 mm) stationary; 1.9 in (48 mm) installation |
| Nominal conductor DCR | 1.68 Ohm/1000ft |
| Temperature rating | 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C |
| UL voltage rating | 600 V (TC-ER), 150 V (NPLF) |