Wire Cable Assemblies

24513D

The Belden 24513D is a Canadian ACIC 600 V instrumentation cable with 4 pairs of 18 AWG stranded tinned copper conductors and XLPE insulation. It includes individual and overall Beldfoil shields, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket rated -40 °C to +90 °C wet / 105 °C dry. It is used for industrial control, raceways, cable trays, digital control, instruments, solenoids, valves, actuators, and positioners.\n\nkey_specs: [\n "Voltage Rating: 600 V",\n "Conductors: 4 Pair 18 AWG 7x26H Tinned Copper",\n "Insulation: XLPE, 0.030 in (0.76 mm) Nom. Thickness",\n "Max. Current: 10.5 Amps per Conductor at 30ºC",\n "Operating Temperature: -40°C To +90°C Wet/105°C Dry",\n "Overall Cable Diameter: 0.949 in",\n "Max. Pull Tension: 414 lbs (188 kg)",\n "Bulk Cable Weight: 361 lbs/1000ft"\n]\n\nabsolute_max_ratings: null\n\npin_table: null\n\nmarking_code: null\n\napplications: [\n "Industrial Control",\n "Raceways Cable trays and ducts",\n "Digital Control",\n "Instruments (4-20ma, 0-10v, ...)",\n "low voltage digital control (24v, …)",\n "encoders",\n "control circuits",\n "distributed control system (DCS)",\n "programmable logic controller (PLC)",\n "Solenoids",\n "Valves",\n "Actuators",\n "Positioners"\n]}

Belden
13 3

24514D

The Belden 24514D is a Canadian TC-ACIC 600 V instrumentation cable with 8 pairs of 18 AWG (7x26) tinned copper conductors, XLPE insulation, individual and overall Beldfoil shields, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket. It is rated for -40 °C to +90 °C wet / 105 °C dry and is intended for industrial control, raceways, cable trays, ducts, and low-voltage digital control circuits. It complies with CEC/C(UL) ACIC and HLABCD and carries China RoHS II compliance.\n\nBuilt for harsh industrial environments, this armored cable supports 4-20 mA and 0-10 V instrumentation, DCS/PLC control circuits, solenoids, valves, actuators, and positioners. Its tinned copper conductors and dual 100% shield coverage provide noise immunity and signal integrity in electrically noisy settings.

Belden
13 3

24519D

The Belden 24519D is a Canadian TC-ACIC 600 V instrumentation cable built with eight triads of 18 AWG (7x26) tinned copper conductors and XLPE insulation. It features individual and overall 100% Beldfoil shielding, a black PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket with ripcord, rated for 90C Wet / 105C Dry operation down to -40C with sunlight resistance.

Belden
13 3

24533D

The Belden 24533D is a Canadian Instrumentation Cable (TC-ACIC) rated for 600 V, constructed with six 16 AWG tinned copper triads, XLPE insulation, individual and overall Beldfoil shielding, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket. It is intended for industrial control, digital control, instruments, encoders, control circuits, DCS, PLCs, solenoids, valves, actuators, and positioners in raceways, cable trays, and ducts. Operating temperature is -40°C to +105°C dry / 90°C wet.

Belden
13 3

25008

The Belden 25008 is an 8-conductor 22 AWG (7/30) tinned copper cable with semi-rigid PVC insulation and a slate polyurethane outer jacket, rated 300 V under AWM/STYLE 20668 and CSA AWM. It is designed for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable carries UL/CSA AWM, VW-1, and FT1 compliance with an operating temperature range of -30 °C to +90 °C.

Belden
13 3

25063

Belden part 25063 is an XTRAGUARD 2, 3-conductor 18 AWG (16/30) tinned copper cable with PVC insulation and a slate polyurethane outer jacket. It is rated 300 V (AWM/CSA) and is intended for data, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Belden
13 3

25114

Belden part 25114 is an XTRAGUARD 2 cable with 4 conductors of 24 AWG (7x32) tinned copper, semi-rigid PVC insulation, an overall aluminum/polyester and tinned copper braid shield, and a slate polyurethane jacket. It is rated at 300 V and is intended for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable has a PUR outer jacket, an overall diameter of 0.203 in (5.16 mm), and an operating temperature range of -30 °C to +90 °C (UL 105 °C).

Belden
13 3

25168

Belden 25168 is an 8-conductor, 18 AWG (16x30) tinned copper cable with PVC insulation, an overall aluminum/polyester plus tinned copper braid shield, and a slate polyurethane outer jacket. It is rated 300 V under AWM/STYLE 20668 and CSA AWM, with an operating temperature range of -30 °C to +90 °C. The cable is intended for data, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The part number appears to be a Belden part but described with Alpha Wire part numbering in the notes.

Belden
13 3

25196

Belden part 25196 is an XTRAGUARD 2, 6-conductor 22 AWG (7x30 stranded tinned copper) cable with semi-rigid PVC insulation, an overall aluminum/polyester shield with a tinned-copper drainwire, and a slate polyurethane outer jacket. It is rated 300 V and is designed for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation. The cable has a nominal overall diameter of 0.223 in (5.66 mm) and complies with UL/CSA AWM, FT1, RoHS, UKCA, and China RoHS requirements.

Belden
13 3

25372

Belden part 25372 is an XTRAGUARD 2 cable with 2 pairs of 18 AWG (16x30) stranded tinned copper conductors, PVC insulation, an overall aluminum/polyester foil shield (100% coverage) with a tinned copper drainwire, and a slate polyurethane outer jacket. It is rated 300 V (AWM 20668 / CSA AWM) and is designed for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Belden
13 3

25384

Belden part 25384 is an XTRAGUARD 2 four-conductor 18 AWG (16/30) tinned copper cable with PVC insulation, an overall aluminum/polyester tape shield, and a slate polyurethane outer jacket. It is rated 300 V and is intended for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Belden
13 3

25483

Belden part 25483 is an XTRAGUARD 2 cable consisting of 3 pairs of 22 AWG stranded tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate polyurethane outer jacket. It is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Belden
13 3

25511D

The Belden 25511D is a Canadian TC-ACIC instrumentation cable rated for 600 V, built with four pairs of 16 AWG (7x24) stranded tinned copper conductors and XLPE insulation. It includes an overall Beldfoil shield, PVC inner jacket, steel interlock armor, and a black PVC outer jacket, and is intended for industrial control, raceways, cable trays, digital control, and instrument signals such as 4–20 mA and 0–10 V.

Belden
13 3

26320FL

Belden 26320FL is an armored plenum-rated fire alarm cable (FPLP) with two 18 AWG solid bare copper conductors, Flamarrest insulation, an overall Beldfoil shield, and aluminum interlock armor under a PVC jacket with ripcord. It is intended for indoor plenum fire alarm, monitor/detection, audio, control, initiating, and notification circuits, including use in noisy environments.

Belden
13 3

26512D

Belden 26512D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, containing 8 triads of 16 AWG (7x24) tinned copper conductors with XLPE insulation, individual and overall Beldfoil shields, a PVC inner jacket, steel interlock armor, and a black PVC outer jacket. It operates from -40 °C to +90 °C wet / 105 °C dry and is intended for industrial control, raceways, cable trays, digital control, instruments, DCS/PLC systems, solenoids, valves, actuators, and positioners.

Belden
13 3

26523

Belden 26523 is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, constructed with two triads of 18 AWG (7x26) tinned copper conductors. It has PVC insulation, individual and overall Beldfoil shields, a PVC inner jacket, steel interlock armor, and a PVC outer jacket, rated for -40 °C to +105 °C dry and -40 °C to +75 °C wet operation.

Belden
13 3

27082A

The Belden 27082A is a UL Type TC (1277) power and control cable with four 14 AWG bare copper conductors (7x22 stranding). It has PVC/nylon insulation, a black PVC outer jacket with ripcord, and is rated 600 V (TC) / 150 V (NPLF) for 90°C dry / 75°C wet operation, with sunlight resistance and direct burial suitability.

Belden
13 3

27085A

Belden 27085A is a 7-conductor, 14 AWG (7x22) bare copper cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V RMS as Type TC and 150 V RMS as NPLF, and is suitable for indoor, outdoor, sunlight-resistant, and direct-burial installations. It is intended for industrial control, raceways, cable trays, digital control, instruments, solenoids, valves, actuators, and positioners.

Belden
13 3

27150A

The Belden 27150A is a UL Type TC power and control cable with three 8 AWG bare copper conductors plus one 10 AWG bare copper ground wire, insulated with PVC/nylon and covered by a black PVC jacket with a ripcord. It is rated 600 V, 90 °C dry / 75 °C wet, and is suitable for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations. The cable is sunlight resistant and rated for direct burial.

Belden
13 3

27152A

The Belden 27152A is a UL Type TC power and control cable with two 6 AWG bare copper conductors and one 8 AWG bare copper ground wire, insulated with PVC/nylon and jacketed in black PVC. It is rated for 600 V and 90 °C dry / 75 °C wet operation and is suitable for indoor, outdoor, sunlight-resistant, and direct burial installations, including Class 1 Division 2 hazardous locations. The cable has no outer shield and includes a ripcord in the jacket.

Belden
13 3