Sitemap - 2
28630A
The Belden 28630A is a 37-conductor, 12 AWG (7x20 stranded bare copper) UL Type TC power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), 90 °C dry/wet, and is suitable for indoor, outdoor, sunlight-resistant, and direct-burial installations including Class 1 Division 2 hazardous locations. The unshielded cable includes a ripcord and has a nominal overall diameter of 1.076 in (27.33 mm).
28617A
The Belden 28617A is a 10-conductor UL Type TC power and control cable with 16 AWG (7x24) stranded bare copper conductors, PVC/nylon insulation, and a black PVC jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90 °C dry/wet temperature rating and suitability for indoor, outdoor, sunlight-resistant, and direct-burial installations. It is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
28615A
Belden 28615A is a UL Type TC (1277) power and control cable with 6 conductors of 16 AWG (7x24) bare copper, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF) at 90 °C dry/wet, is sunlight resistant and suitable for direct burial, and is recommended for power and control applications up to 600 V including Class 1 Division 2 hazardous locations.
28609A
The Belden 28609A is a UL Type TC (1277) power and control cable containing 19 conductors of 18 AWG bare copper (7x26 stranding) with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), operates wet/dry from -30°C to 90°C, and is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
28605A
The Belden 28605A is a UL Type TC (1277) power and control cable with 15 bare copper conductors sized 18 AWG (7x26 stranding), PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90°C dry/wet temperature rating, and is suitable for indoor, outdoor, sunlight-resistant, and direct-buried installations, including Class 1 Division 2 hazardous locations.
28601A
Belden 28601A is a UL Type TC power and control cable with eight 18 AWG (7x26) bare copper conductors, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90 °C dry/wet UL temperature and -30 °C to +90 °C operating temperature. It is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, and is sunlight resistant and rated for direct burial.{
28600A
The Belden 28600A is a 6-conductor 18 AWG (7x26) bare copper cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90 °C dry/wet temperature ratings, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
28339A
The Belden 28339A is a 5-conductor, 16 AWG (7x24) bare copper power and control cable with PVC/nylon insulation (E2 color code: black, red, blue, orange, yellow) and a black PVC outer jacket with a ripcord. It is rated 600 V (TC-ER) and 150 V (NPLF) and is suitable for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations. The unshielded cable is rated 90 °C dry/wet with an operating range of -30 °C to 90 °C wet/dry and is suitable for indoor, outdoor, sunlight-resistant, and direct-burial use.
28331A
Belden 28331A is a UL Type TC (1277) power and control tray cable with three 16 AWG (7x24) bare copper conductors, PVC-nylon insulation (E2), and a black PVC outer jacket with ripcord. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry/wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations.
28178A
The Belden 28178A is a UL Type TC power and control cable with four 4/0 AWG bare copper conductors plus one 4 AWG bare copper ground conductor. It features PVC/nylon insulation, a black PVC outer jacket with ripcord, and is rated 600 V, 90 °C dry/wet, with sunlight resistance and suitability for direct burial and Class 1 Division 2 hazardous locations.
28175A
The Belden 28175A is a UL Type TC power and control cable with four 3/0 AWG bare copper conductors and one uninsulated 4 AWG bare copper ground conductor. It features PVC/nylon insulation, a black PVC jacket with ripcord, and is rated 600 V, 90 °C dry/wet, suitable for indoor, outdoor, sunlight-resistant, direct-burial, and Class 1 Division 2 hazardous locations.
28169A
Belden 28169A is a UL Type TC power and control cable rated 600 V, constructed with four 1/0 AWG bare copper conductors (19x12 stranding) and one 6 AWG bare copper ground wire (7x14 stranding). The conductors use PVC/nylon M4 insulation, are black and numbered, and are covered by a black PVC outer jacket with a ripcord. It is rated 90 °C dry/wet and is suitable for indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial installations, including Class 1 Division 2 hazardous locations.
28163A
The Belden 28163A is a 19-conductor, 10 AWG (7x18) bare copper cable with PVC/nylon insulation and a black PVC outer jacket, rated 600 V TC-ER for 90 °C dry/wet use. It is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations, and is rated for indoor, outdoor, sunlight/UV resistance and direct burial. It has no overall shield and includes a ripcord.
28161A
The Belden 28161A is a UL Type TC power and control cable with three 1 AWG bare copper conductors plus one 6 AWG bare copper ground wire, PVC-nylon insulation, and a black PVC jacket rated 600 V. It is rated 90 °C dry and wet, is sunlight resistant and suitable for direct burial, and is intended for power and control applications up to 600 V including Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 1.125 in (28.58 mm), a maximum pull tension of 3408.3 lbs (1546.0 kg), and a bulk weight of 1177 lbs/1000 ft.
28160A
The Belden 28160A is a UL Type TC power and control cable consisting of four 2 AWG bare copper conductors plus one 6 AWG bare copper ground conductor. It has PVC/nylon insulation and a black PVC outer jacket, is rated 600 V and 90 °C dry/wet, and is suitable for indoor, outdoor, sunlight-resistant, and direct burial use including Class 1 Division 2 hazardous locations. A 5,000 ft reel put-up (item 28160A 0105000) is available with a ripcord in the jacket.
28156A
The Belden 28156A is a UL Type TC power and control cable with three 4 AWG bare copper conductors and one 8 AWG bare copper ground conductor, insulated with PVC/nylon and covered by a black PVC jacket with a ripcord. It is rated 600 V (TC-ER), 90 °C dry and wet, and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable is sunlight resistant and rated for direct burial.
28148A
The 28148A is a Belden UL Type TC power and control cable with 12 conductors of 10 AWG bare copper (7x18 stranding), PVC-nylon insulation, and a black PVC jacket rated 600 V. It is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with 90 °C dry/wet ratings and sunlight resistance for direct burial.
28132A
The Belden 28132A is a 25-conductor power and control cable built with 12 AWG (7x20) bare copper conductors, PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF) at 90°C dry/wet and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
28119A
Belden 28119A is a 12-conductor, 12 AWG (7x20) bare copper power and control cable with PVC/nylon insulation, E2 color code, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry/wet, suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with sunlight resistance and direct burial approval. The cable has no shield, includes a ripcord, and has a nominal overall diameter of 0.666 in (16.9 mm).
28116A
The Belden 28116A is a 9-conductor, 12 AWG (7x20 stranded bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90 °C dry/wet UL temperature rating, and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, including indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial use.