28605A Datasheet

BeldenBulk Wire Cable

The Belden 28605A is a UL Type TC (1277) power and control cable with 15 bare copper conductors sized 18 AWG (7x26 stranding), PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90°C dry/wet temperature rating, and is suitable for indoor, outdoor, sunlight-resistant, and direct-buried installations, including Class 1 Division 2 hazardous locations.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

28605A Key Specifications

Maximum current
24 Amps per Conductor at 30ºC
Voltage rating
600 V (TC-ER), 150 V (NPLF)
Temperature rating
90°C Dry, 90°C Wet (UL); operating Wet/Dry: -30°C to 90°C
Bulk cable weight
203 lbs/1000ft
Conductor count / size / material
15 conductors, 18 AWG, 7x26 BC - Bare Copper
Maximum pull tension
336 lbs (152 kg)
Nominal conductor DCR
7.06 Ohm/1000ft
Overall cable diameter
0.503 in (12.8 mm)

Characteristics (datasheet)

Conductor count / size / material
15 conductors, 18 AWG, 7x26 BC - Bare Copper
Voltage rating
600 V (TC-ER), 150 V (NPLF)
Temperature rating
90°C Dry, 90°C Wet (UL); operating Wet/Dry: -30°C to 90°C
Nominal conductor DCR
7.06 Ohm/1000ft
Maximum current
24 Amps per Conductor at 30ºC
Overall cable diameter
0.503 in (12.8 mm)
Maximum pull tension
336 lbs (152 kg)
Bulk cable weight
203 lbs/1000ft

28605A Applications

  • Power and Control Applications up to 600V
  • Class 1 Division 2 Hazardous Locations

Other Belden parts

  • 1369P — The Belden 1369P is a plenum-rated (CMP) RG6 serial digital coaxial cable design...
  • 78145 — The Belden 78145 is an ECOCABLE consisting of 5 pairs of 20 AWG tinned copper co...
  • 3089A — The Belden 3089A is a UL-listed instrumentation cable featuring a single 18 AWG...
  • 76112WS — The Belden 76112WS is a MachFlex™ high-flex 12-conductor cable designed for dyna...
  • 9392 — The Belden 9392 is a high-performance instrumentation cable consisting of 15 pai...
  • 3220 — The Belden 3220 is a single-conductor communication and control cable designed f...
  • 1138C — The Belden 1138C is an 8-pair, 18 AWG tinned copper conductor communication and...
  • 39126 — Belden 39126 is a 26 AWG (7x34) stranded tinned copper lead wire with PPO (polyp...

More Bulk Wire Cable

  • 35606 — The Belden 35606 is a 6 AWG rubber lead wire with a 133x27 stranded tinned coppe...
  • 86702CY — The 86702CY is an XTRAGUARD FLEX continuous flex data cable consisting of 2 pair...
  • 83756 — The Belden 83756 is a high-temperature electronic cable consisting of six 14 AWG...
  • 9684 — The Belden 9684 is a computer EIA RS-232/422 low-capacitance cable designed for...
  • 8457 — The Belden 8457 is a 12-conductor electronic cable featuring 22 AWG (7x30) tinne...
  • 21676 — The Belden 21676 is a CSA Tray TC-CIC 600 V power cable containing four 3/0 AWG...
  • 86405CY — The 86405CY is an XTRAGUARD FLEX continuous flex data cable with 5 pairs of 28 A...
  • 5535 — The Belden 5535 is a shielded, 5-conductor cable constructed with 16 AWG strande...

28605A FAQ

What is 28605A?

28605A is a Bulk Wire Cable from Belden. The Belden 28605A is a UL Type TC (1277) power and control cable with 15 bare copper conductors sized 18 AWG (7x26 stranding), PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90°C dry/wet temperature rating, and is suitable for indoor, outdoor, sunlight-resistant, and direct-buried installations, including Class 1 Division 2 hazardous locations.

Who manufactures 28605A?

28605A is manufactured by Belden.

Where can I download the 28605A datasheet PDF?

The 28605A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 28605A specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk cable weight203 lbs/1000ft
Conductor count / size / material15 conductors, 18 AWG, 7x26 BC - Bare Copper
Maximum current24 Amps per Conductor at 30ºC
Maximum pull tension336 lbs (152 kg)
Nominal conductor DCR7.06 Ohm/1000ft
Overall cable diameter0.503 in (12.8 mm)
Temperature rating90°C Dry, 90°C Wet (UL); operating Wet/Dry: -30°C to 90°C
Voltage rating600 V (TC-ER), 150 V (NPLF)