The Belden 28116A is a 9-conductor, 12 AWG (7x20 stranded bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90 °C dry/wet UL temperature rating, and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, including indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial use.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
28116A Key Specifications
- Max current
- 21 Amps per conductor at 30ºC
- Voltage rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature rating
- UL: 90°C Dry, 90°C Wet; Operating: -25°C To +90°C
- Conductor construction
- 9 conductors, 12 AWG, 7x20 stranded bare copper (BC)
- Insulation
- PVC/Nylon (Polyvinyl Chloride + Nylon), nom. thickness 0.021 in (0.53 mm), nom. insulation diameter 0.134 in
- Max pull tension / weight
- 781.2 lbs (354.3 kg); bulk cable weight 289 lbs/1000ft
- Nominal conductor DCR
- 1.7 Ohm/1000ft
- Outer jacket
- Black PVC, nom. thickness 0.063 in (1.6 mm), nom. diameter 0.610 in (15.5 mm), ripcord yes
Characteristics (datasheet)
- Conductor construction
- 9 conductors, 12 AWG, 7x20 stranded bare copper (BC)
- Insulation
- PVC/Nylon (Polyvinyl Chloride + Nylon), nom. thickness 0.021 in (0.53 mm), nom. insulation diameter 0.134 in
- Outer jacket
- Black PVC, nom. thickness 0.063 in (1.6 mm), nom. diameter 0.610 in (15.5 mm), ripcord yes
- Voltage rating
- 600 V (TC-ER), 150 V (NPLF)
- Max current
- 21 Amps per conductor at 30ºC
- Nominal conductor DCR
- 1.7 Ohm/1000ft
- Temperature rating
- UL: 90°C Dry, 90°C Wet; Operating: -25°C To +90°C
- Max pull tension / weight
- 781.2 lbs (354.3 kg); bulk cable weight 289 lbs/1000ft
28116A Applications
- Power and Control Applications up to 600V
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 7960A — The Belden 7960A is an Industrial Ethernet Cat 5e quad cable with two pairs of 2...
- 83321E — The Belden 83321E is a high-temperature, dual-conductor 18 AWG silver-plated cop...
- 34410 — Belden 34410 is a 10 AWG (65x28) stranded tinned copper lead wire with CSPE (chl...
- 57010 — The Belden 57010 is a plenum-rated, shielded communication and control cable fea...
- 26513D — Belden 26513D is a 300 V Canadian Instrumentation Cable (TC-ACIC) with 12 triads...
- 77211 — The Belden 77211 is a multi-conductor ECOCABLE featuring 12 conductors of 20 AWG...
- 70257PU — The Belden 70257PU is a highly flexible, halogen-free, and flame-retardant PUR s...
- 5322C — The 5322C is a 12-conductor, 20 AWG tinned copper cable with semi-rigid PVC insu...
More Bulk Wire Cable
- 8403 — The Belden 8403 is a 3-conductor, 20 AWG tinned copper microphone cable with pol...
- 8825 — The Belden 8825 is a low-temperature plastic lead wire kit on racks, consisting...
- 1037A — The 1037A is a black-jacketed instrumentation cable designed for industrial cont...
- 8781MN — The 8781MN is a SpaceMaker™ 5-pair 22AWG tinned copper cable with polypropylene...
- 83267 — The Belden 83267 is a 75 Ohm coaxial cable (RG 187) featuring a 30 AWG stranded...
- 1041A — The Belden 1041A is an 8-pair, 16 AWG bare copper instrumentation cable with PVC...
- 6158 — The Belden 6158 is a heavy-duty Teck90 1000V cable featuring 2+G bare copper con...
- 76030 — The Belden 76030 is a high-flex Category 5e UTP cable with 4 pairs of 24 AWG tin...
28116A FAQ
What is 28116A?
28116A is a Bulk Wire Cable from Belden. The Belden 28116A is a 9-conductor, 12 AWG (7x20 stranded bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90 °C dry/wet UL temperature rating, and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, including indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial use.
Who manufactures 28116A?
28116A is manufactured by Belden.
Where can I download the 28116A datasheet PDF?
The 28116A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 28116A specifications
Click to ask a quick question:
Parameters
| Conductor construction | 9 conductors, 12 AWG, 7x20 stranded bare copper (BC) |
| Insulation | PVC/Nylon (Polyvinyl Chloride + Nylon), nom. thickness 0.021 in (0.53 mm), nom. insulation diameter 0.134 in |
| Max current | 21 Amps per conductor at 30ºC |
| Max pull tension / weight | 781.2 lbs (354.3 kg); bulk cable weight 289 lbs/1000ft |
| Nominal conductor DCR | 1.7 Ohm/1000ft |
| Outer jacket | Black PVC, nom. thickness 0.063 in (1.6 mm), nom. diameter 0.610 in (15.5 mm), ripcord yes |
| Temperature rating | UL: 90°C Dry, 90°C Wet; Operating: -25°C To +90°C |
| Voltage rating | 600 V (TC-ER), 150 V (NPLF) |