Sitemap - 2

21626

Belden 21626 is a CSA Tray TC-CIC 600 V power and control cable with 28 conductors of 10 AWG bare copper (7x18 stranding) plus a 12 AWG bare copper ground. It features XLPE/XLPO/XLP thermoset insulation, a black PVC outer jacket with ripcord, and is rated for -40 °C to +90 °C dry/wet use with sunlight resistance and direct burial suitability for CEC power and control applications. It complies with FT4, C22.2#230 Type TC, C22.2#239 Type CIC, and carries CE/RoHS/WEEE and China RoHS II marks.{

BeldenBulk Wire Cable
17 3

21595

Belden 21595 is a Canadian Instrumentation Cable (TC-CIC) rated 600 V with 47 plus ground conductors. It uses 12 AWG (7x20) bare copper conductors with XLPE insulation and a black PVC outer jacket, and is listed for CEC power and control applications. It is rated for wet/dry operation from -40 °C to 90 °C and is sunlight resistant and suitable for direct burial.

BeldenBulk Wire Cable
17 4

29558C

Belden 29558C is a 3-conductor VFD power cable with 1/0 AWG bare copper conductors, XLPE insulation, and three 10 AWG segmented bare copper grounds, plus dual 100% coverage helical copper tape shielding and a black PVC jacket. It is rated 1000 V (CSA TC) and intended for variable frequency drives, AC motor and drive systems, and Canadian applications. The cable is suitable for indoor, outdoor, sunlight-resistant, oil-resistant, and direct burial use.

BeldenBulk Wire Cable
16 3

29532

Belden 29532 is a flexible 600/1000 V VFD motor supply cable with three 4/0 AWG tinned copper conductors and XLPE insulation. It includes three segmented 2 AWG bare copper ground wires (totaling 4/0 AWG) and dual helical bare copper tape shields at 100% coverage under a black PVC jacket. It is rated 90 °C dry/wet and intended for variable frequency drives, AC motor and drive systems, and Class 1 Division 2 hazardous locations.

BeldenBulk Wire Cable
16 4

29528

Belden 29528 is a flexible 600/1000 V VFD motor supply cable with three 1 AWG (7x19x22) tinned copper conductors and XLPE insulation, plus a segmented 1 AWG bare copper ground (3 of 6 AWG). It uses dual 100% coverage helical bare copper tape shields and a black PVC jacket with ripcord, rated 90 °C dry/wet for TC-ER and WTTC use. It is intended for variable frequency drives, AC motor and drive systems, and Class 1 Division 2 hazardous locations.

BeldenBulk Wire Cable
16 2

29511

Belden 29511 is a flexible 600 V/1000 V motor supply cable built for variable frequency drives (VFD) and AC motor and drive systems. It contains three 14 AWG tinned copper power conductors with XLPE insulation, a 14 AWG PVC ground wire (300% ground), an overall Beldfoil plus 85% tinned copper braid shield, and one separately foil-shielded 16 AWG control/brake pair under a black PVC jacket. It is rated 90 °C dry/wet, suitable for Class 1 Division 2 hazardous locations, and complies with TC-ER, UL Flexible Motor Supply Cable, and AWM I/II A/B requirements.\n\nIt is a cable assembly, so it has no pinout, no absolute maximum ratings table, and no top marking code listed in the datasheet.\n\nKey specs: 1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC), 1000 V (AWM I/II A/B); 90 °C Dry, 90 °C Wet UL / -40 °C to +90 °C operating; 3 × 14 AWG (41×30) TC power conductors + 14 AWG TC ground + 1 pair 16 AWG (26×30) TC; 25 A per conductor at 30 °C (3 current-carrying conductors), 18 A per conductor for the pair (per NEC); overall diameter 0.820 in (20.8 mm); max pull tension 441 lbs (200 kg); min bend radius 9.8 in (250 mm) stationary and installation; weight 275 lbs/1000 ft (409 kg/km).\n\nApplications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations.\n\nmarking_code: null\npin_table: []\nabsolute_max_ratings: []

BeldenBulk Wire Cable
16 4

29507

Belden 29507 is a flexible 600/1000 V TC-ER WTTC motor supply cable built with three 2 AWG tinned copper conductors, XLPE insulation, and a PVC-insulated ground wire. It includes four 8 AWG segmented tinned-copper ground/drain wires, an overall Beldfoil plus 87% tinned copper braid shield, and a black PVC jacket with ripcord. Rated for 90°C dry/wet operation (-40°C to +90°C), it is intended for variable frequency drives, AC motor and drive systems, and Class 1 Division 2 hazardous locations.

BeldenBulk Wire Cable
16 3

29006

Belden 29006 is a 600 V ACIC power and control cable with twelve 16 AWG stranded bare copper conductors plus a bare copper ground wire. It uses cross-linked polyethylene insulation, a PVC inner jacket, aluminum interlocked armor, and a PVC outer jacket, and is suitable for indoor, outdoor, sunlight-resistant, and burial installations up to 600 V.

BeldenBulk Wire Cable
16 3

28629A

The Belden 28629A is a UL Type TC power and control cable containing 37 conductors of 14 AWG (7x22) bare copper with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.

BeldenBulk Wire Cable
16 3

28624A

Belden 28624A is a 19-conductor Type TC power and control cable using 16 AWG (7x24) bare copper conductors with PVC/nylon insulation and a black PVC jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry/wet, and is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.

BeldenBulk Wire Cable
16 3

28613A

Belden 28613A is a 37-conductor 18 AWG (7x26) bare copper power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90°C dry and wet temperature ratings, and is suited for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.728 in (18.5 mm) and a maximum pull tension of 828.8 lbs (375.9 kg).

BeldenBulk Wire Cable
16 4

28341A

Belden 28341A is a 12-conductor power and control cable built with 16 AWG (7x24) bare copper conductors, PVC/nylon E2 insulation, and a black PVC outer jacket with ripcord. It is rated 600 V (TC-ER) and 150 V (NPLF), 90 °C dry/wet, and is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.

BeldenBulk Wire Cable
16 3

28338A

Belden 28338A is a UL Type TC (1277) power/control cable with four 16 AWG (7x24) bare copper conductors, PVC-nylon E2 insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), 90 °C dry/wet, sunlight resistant and suitable for direct burial, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations. No pinout or absolute maximum ratings apply because this is a bulk cable rather than a pin-based electronic component. It carries no separate top-side marking code in the datasheet. The stated applications are power and control applications up to 600 V and Class 1 Division 2 hazardous locations. Key specs include 4 x 16 AWG (7x24) bare copper conductors, PVC/nylon insulation at 0.020 in (0.51 mm), PVC jacket at 0.047 in (1.2 mm) with 0.331 in (8.41 mm) nominal diameter, 4.2 Ohm/1000ft nominal conductor DCR, 14.4 A max current per conductor at 30 °C, 140 lbs (64 kg) max pull tension, and 71 lbs/1000ft bulk weight. There is no Absolute Maximum Ratings table or pin-by-pin table in this document.

BeldenBulk Wire Cable
16 4

28329A

Belden 28329A is a UL Type TC (1277) PVC-nylon/PVC multi-conductor cable with 12 conductors of 18 AWG (7x26) bare copper, PVC-nylon E2 color-coded insulation, and a black PVC outer jacket with ripcord. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with sunlight resistance and direct burial approval.

BeldenBulk Wire Cable
16 2

28328A

The 28328A is a Belden UL Type TC power and control cable with 10 conductors of 18 AWG (7x26) bare copper, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.442 in and is sunlight resistant and rated for direct burial.

BeldenBulk Wire Cable
16 3

28326A

The Belden 28326A is a 4-conductor, 18 AWG (7x26 stranded bare copper) power and control cable with PVC/nylon conductor insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with a 90 °C dry/wet rating and an operating range of -30 °C to 90 °C. It is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, and is sunlight resistant and suitable for direct burial.\n\n

BeldenBulk Wire Cable
16 3

28177A

Belden 28177A is a UL Type TC (1277) power and control cable with three 4/0 AWG bare copper conductors plus one 4 AWG bare copper ground conductor, PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER), 90 °C dry and wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations. A recommended cable gland is Belden BTC200A1741RA.

BeldenBulk Wire Cable
16 8

28171A

The Belden 28171A is a UL Type TC power and control cable with three 2/0 AWG bare copper conductors plus a 6 AWG bare copper ground, PVC/nylon insulation, and a black PVC jacket rated 600 V. It is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with a 90°C dry/wet temperature rating and sunlight-resistant, direct-burial construction.

BeldenBulk Wire Cable
16 3

28153A

Belden part 28153A is a UL Type TC power and control cable with three bare copper 6 AWG conductors (7x14 stranding) plus one bare copper 8 AWG ground conductor (7x16 stranding), PVC-nylon insulation, and a black PVC jacket rated 600 V. It is suitable for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations, and is rated 90 °C dry/wet with sunlight resistance and direct burial suitability.

BeldenBulk Wire Cable
16 3

28150A

The Belden 28150A is a UL Type TC (1277) power and control cable rated for 600 V, with three 8 AWG bare copper conductors and one 10 AWG bare copper ground wire, PVC/nylon insulation, and a black PVC outer jacket. It is rated 90 °C dry and 90 °C wet, is sunlight resistant and suitable for direct burial, and is listed for Class 1 Division 2 hazardous locations. Suitable applications are power and control applications up to 600 V.

BeldenBulk Wire Cable
16 3