28111A

The Belden 28111A is a 4-conductor, 12 AWG (7x20 bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90°C dry/wet temperature rating, and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable is sunlight resistant, rated for direct burial, and suitable for indoor and outdoor use.

BeldenBulk Wire Cable
17 3

28097A

Belden 28097A is a UL Type TC power and control cable with 19 conductors of 14 AWG bare copper (7x22 stranding), PVC/nylon insulation, and a black PVC jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90 °C dry/wet temperature rating, and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has no shield, includes a ripcord, and has a nominal overall diameter of 0.686 in (17.4 mm).

BeldenBulk Wire Cable
17 3

27643A

Belden 27643A is a UL Type TC power and control cable with two 10 AWG bare copper conductors (7x18 stranding), PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V, 90 °C dry and wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations. Recommended applications are power and control circuits up to 600 V. The cable has no shield and includes a ripcord in the jacket.

BeldenBulk Wire Cable
17 3

27149A

Belden 27149A is a UL Type TC power and control cable with two 8 AWG bare copper conductors (7x16 stranding) and one 10 AWG bare copper ground wire (7x18 stranding). It uses PVC/nylon conductor insulation and a black PVC jacket, rated 600 V and 90°C Dry / 75°C Wet, and is suitable for indoor, outdoor, sunlight-resistant, direct burial, and Class 1 Division 2 hazardous locations. No pinout or absolute maximum ratings table applies to this cable product.\n\n"}]}

BeldenBulk Wire Cable
17 4

26506D

The Belden 26506D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, built with 12 pairs of 16 AWG (7x24) stranded tinned copper conductors with XLPE insulation. It includes individual and overall Beldfoil shielding, a PVC inner jacket, steel interlock armor, and a black PVC outer jacket, rated for 90 °C wet / 105 °C dry and -40 °C with sunlight resistance. It is intended for industrial control, raceways, digital control, instruments, DCS, PLC, solenoids, valves, actuators, and positioners.

BeldenBulk Wire Cable
17 5

26220FL

The Belden 26220FL is an armored plenum-rated fire alarm cable (FPLP) with two 16 AWG solid bare copper conductors, Flamarrest insulation, an overall Beldfoil shield with 100% coverage, and aluminum interlock armor with a PVC jacket and ripcord. It is intended for indoor plenum fire alarm, monitor/detection, audio, control, initiating, and notification circuits in noisy environments. The cable meets NFPA 262 / UL 910 plenum flammability requirements and NEC Article 760 FPLP compliance.\n\n

BeldenBulk Wire Cable
17 3

25543

The Belden 25543 is an XTRAGUARD 2 cable with three 14 AWG (41x30) tinned copper conductors, PVC insulation, and an overall shield consisting of 100% aluminum/polyester plus 70% tinned copper braid, under a slate polyurethane jacket with ripcord. It is rated 600 V for AWM 20669 and CSA/TEW use and is intended for data, communication, audio, low-level signal, industrial networking, serial communication, control panel, automation, and instrumentation systems. It operates from -30°C to +90°C (UL temperature 105°C).

BeldenBulk Wire Cable
17 3

25539

Belden 25539 is an XTRAGUARD 2 cable with 9 conductors of 16 AWG (19x29) tinned copper, PVC insulation, an overall aluminum/polyester shield, and a slate polyurethane outer jacket rated 600 V. It is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

BeldenBulk Wire Cable
17 4

25514D

The Belden 25514D is a Canadian instrumentation cable rated TC-ACIC 600 V, built with two 18 AWG tinned copper pairs (7x26 stranding), XLPE insulation, and individual plus overall Beldfoil shields. It features a PVC inner jacket, steel interlock armor, and a black PVC outer jacket, rated for 90 °C wet and 105 °C dry operation from -40 °C. It is intended for industrial control, raceways, cable trays and ducts, digital control, instruments, encoders, DCS/PLC systems, solenoids, valves, actuators, and positioners.

BeldenBulk Wire Cable
17 4

25276

Belden part 25276 is an XTRAGUARD 2 cable consisting of 6 pairs of 24 AWG (7x32) stranded tinned copper conductors with semi-rigid PVC insulation, an overall bi-laminate aluminum/polyester shield with drainwire plus a 70% tinned copper braid, and a slate polyurethane outer jacket. It is rated 300 V and is intended for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

BeldenBulk Wire Cable
17 3

25272

Belden 25272 is an XTRAGUARD 2 cable with 2 pairs of 24 AWG (7x32) stranded tinned copper conductors, semi-rigid PVC insulation, an overall aluminum/polyester foil shield plus 70% tinned copper braid, and a slate polyurethane outer jacket. It is rated 300 V and is intended for data, communication, audio, and low-level signal transmission such as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable has a nominal overall diameter of 0.240 in (6.10 mm), operates from -30°C to +90°C (UL 105°C), and complies with AWM 20668, VW-1, FT1, RoHS, and UKCA.}

BeldenBulk Wire Cable
17 4

25194

Belden 25194 is an XTRAGUARD 2 cable with 4 conductors of 22 AWG (7/30) tinned copper, semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate polyurethane outer jacket. It is rated at 300 V and is intended for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable complies with UL/CSA AWM styles, VW-1/FT1 flammability ratings, and RoHS/UKCA/China RoHS directives.

BeldenBulk Wire Cable
17 3

25100UE

The Belden 25100UE is an armored security and commercial audio cable with two 14 AWG stranded bare copper conductors. It uses polypropylene insulation, a 100% polyester tape shield, a brown PVC inner jacket, and aluminum interlock armor, and is rated for 300 V UL and indoor riser use.

BeldenBulk Wire Cable
17 5

23548D

Belden 23548D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, containing 8 triads (24 conductors) of 20 AWG 7x28 tinned copper. It uses XLPE insulation, individual and overall Beldfoil shielding, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket, rated 90C wet / 105C dry with -40C suitability for industrial control and instrumentation wiring.

BeldenBulk Wire Cable
17 5

23526D

The Belden 23526D is a Canadian instrumentation cable (TC-ACIC) rated 300 V with eight 16 AWG tinned copper triads and XLPE insulation. It has individual and overall Beldfoil shielding, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated for -40 °C to +105 °C dry / 90 °C wet operation and is suitable for industrial control, DCS/PLC, instruments, solenoids, valves, actuators, and positioners.

BeldenBulk Wire Cable
17 3

22646D

Belden 22646D is a Canadian Instrumentation Cable (CIC) rated 300 V, built as one shielded pair of 16 AWG (7x24) tinned copper conductors with XLPE insulation and a black PVC outer jacket. It has an overall Beldfoil shield with 100% coverage plus a drainwire, and is listed for CEC power and control applications in indoor, outdoor, sunlight-resistant, and UV-resistant environments. The cable operates from -40 °C to +90 °C and installs from -25 °C to +90 °C.

BeldenBulk Wire Cable
17 2

22645

Belden part 22645 is a Canadian Instrumentation Cable (TC-CIC) rated 300 V RMS, built with one 18 AWG (7x26) tinned copper pair insulated with PVC in black and white color code. It has an overall Beldfoil bi-laminate shield with 100% coverage and a 20 AWG tinned copper drainwire, covered by a black PVC jacket with ripcord, rated 105°C dry / 75°C wet and sunlight resistant to -25°C. It is suitable for indoor/outdoor use and complies with C22.2#239 Type CIC and CEC/C(UL) CIC standards.

BeldenBulk Wire Cable
17 3

21639

Belden 21639 is a CSA Tray Cable type TC-CIC rated 600 V, containing 41 conductors of 10 AWG bare copper (7x18 stranded) plus one 12 AWG bare copper ground conductor. It features XLPE/XLPO thermoset insulation, individual black numbered conductors with a green ground, a black PVC outer jacket with ripcord, and is rated 90 °C dry/wet for direct burial, sunlight-resistant indoor/outdoor CEC power and control applications. It includes no shield and has an overall nominal diameter of 1.516 in (38.51 mm).

BeldenBulk Wire Cable
17 4

21635

Belden part 21635 is a CSA TC-CIC 600 V tray cable with 37 conductors of 10 AWG (7x18) bare copper plus one 12 AWG bare copper ground conductor. It features XLPE insulation, a black PVC jacket with ripcord, and is rated 90°C dry/wet for direct burial, sunlight resistance, and CEC power and control applications. The cable has no outer shield and an overall nominal diameter of 1.462 in (37.13 mm).

BeldenBulk Wire Cable
17 4

21629

Belden part 21629 is a CSA Tray TC-CIC 600 V cable containing 31 conductors of 10 AWG bare copper (7×18 stranding) with a 12 AWG bare copper ground wire. It uses XLPE thermoset insulation, a black PVC outer jacket with ripcord, and is rated for −40 °C to +90 °C dry/wet operation, with sunlight resistance and direct burial suitability for CEC power and control applications. It complies with FT4 flame rating, C22.2#230 Type TC, C22.2#239 Type CIC, CEC/C(UL) TC and CIC, and RoHS 2/WEEE directives.

BeldenBulk Wire Cable