28329A Datasheet

BeldenBulk Wire Cable

Belden 28329A is a UL Type TC (1277) PVC-nylon/PVC multi-conductor cable with 12 conductors of 18 AWG (7x26) bare copper, PVC-nylon E2 color-coded insulation, and a black PVC outer jacket with ripcord. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with sunlight resistance and direct burial approval.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

28329A Key Specifications

Max current
24 Amps per Conductor at 30ºC
Voltage rating
600 V (TC-ER), 150 V (NPLF)
Temperature rating
90°C Dry, 90°C Wet; Wet/Dry: -30°C to 90°C
Conductor count / size / material
12 conductors, 18 AWG (7x26), BC - Bare Copper
Insulation / jacket
PVC/Nylon insulation E2; Black PVC outer jacket
Max pull tension / bulk weight
264 lbs (120 kg); 134 lbs/1000ft
Nom. conductor DCR
6.7 Ohm/1000ft
Overall cable diameter (nominal)
0.455 in (11.6 mm)

Characteristics (datasheet)

Conductor count / size / material
12 conductors, 18 AWG (7x26), BC - Bare Copper
Insulation / jacket
PVC/Nylon insulation E2; Black PVC outer jacket
Voltage rating
600 V (TC-ER), 150 V (NPLF)
Temperature rating
90°C Dry, 90°C Wet; Wet/Dry: -30°C to 90°C
Max current
24 Amps per Conductor at 30ºC
Nom. conductor DCR
6.7 Ohm/1000ft
Overall cable diameter (nominal)
0.455 in (11.6 mm)
Max pull tension / bulk weight
264 lbs (120 kg); 134 lbs/1000ft

28329A Applications

  • Power and Control Applications up to 600V
  • Class 1 Division 2 Hazardous Locations

Other Belden parts

  • 22645 — Belden part 22645 is a Canadian Instrumentation Cable (TC-CIC) rated 300 V RMS,...
  • 8167 — The Belden 8167 is a computer EIA RS-232/422 digital audio cable containing 7 in...
  • 934069103 — HIRSCHMANN TEST AND MEASUREMENT 934069103 Test Lead, 4mm Banana Plug to 4mm...
  • 23554D — Belden 23554D is a Canadian TC-ACIC instrumentation cable with 36 pairs of 18 AW...
  • 8500 — The Belden 8500 is a low-temperature plastic lead wire with a 16 AWG stranded ti...
  • 86704CY — The Belden 86704CY is an XTRAGUARD FLEX continuous flex data cable featuring 4 p...
  • 86018CY — The Belden 86018CY is an 18-conductor, 28 AWG tinned copper cable with semi-rigi...
  • 9949 — The Belden 9949 is a computer EIA RS-232 cable consisting of 37 conductors of 22...

More Bulk Wire Cable

  • 22654D — The Belden 22654D is a Canadian Instrumentation Cable (TC-CIC) rated 300 V, buil...
  • 78063 — The Belden 78063 is an ECOCABLE consisting of three pairs of 26 AWG stranded tin...
  • 75002 — The Belden 75002 is a 2-pair 24 AWG solid bare copper industrial ethernet cable...
  • 6826 — The Belden 6826 is a single-conductor hook-up wire featuring 17 AWG bare copper...
  • 45273 — Belden part 45273 is an XTRAGUARD 4 cable containing 3 pairs of 24 AWG (7x32) st...
  • 1823R — The Belden 1823R is a discontinued 32-pair audio snake cable featuring 22 AWG ti...
  • 9829 — The Belden 9829 is a computer EIA RS-232/422 low-capacitance cable featuring two...
  • 28110A — The Belden 28110A is a UL Type TC (1277) power and control cable with three 12 A...

28329A FAQ

What is 28329A?

28329A is a Bulk Wire Cable from Belden. Belden 28329A is a UL Type TC (1277) PVC-nylon/PVC multi-conductor cable with 12 conductors of 18 AWG (7x26) bare copper, PVC-nylon E2 color-coded insulation, and a black PVC outer jacket with ripcord. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with sunlight resistance and direct burial approval.

Who manufactures 28329A?

28329A is manufactured by Belden.

Where can I download the 28329A datasheet PDF?

The 28329A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 28329A specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor count / size / material12 conductors, 18 AWG (7x26), BC - Bare Copper
Insulation / jacketPVC/Nylon insulation E2; Black PVC outer jacket
Max current24 Amps per Conductor at 30ºC
Max pull tension / bulk weight264 lbs (120 kg); 134 lbs/1000ft
Nom. conductor DCR6.7 Ohm/1000ft
Overall cable diameter (nominal)0.455 in (11.6 mm)
Temperature rating90°C Dry, 90°C Wet; Wet/Dry: -30°C to 90°C
Voltage rating600 V (TC-ER), 150 V (NPLF)