29511 Datasheet
Belden 29511 is a flexible 600 V/1000 V motor supply cable built for variable frequency drives (VFD) and AC motor and drive systems. It contains three 14 AWG tinned copper power conductors with XLPE insulation, a 14 AWG PVC ground wire (300% ground), an overall Beldfoil plus 85% tinned copper braid shield, and one separately foil-shielded 16 AWG control/brake pair under a black PVC jacket. It is rated 90 °C dry/wet, suitable for Class 1 Division 2 hazardous locations, and complies with TC-ER, UL Flexible Motor Supply Cable, and AWM I/II A/B requirements.\n\nIt is a cable assembly, so it has no pinout, no absolute maximum ratings table, and no top marking code listed in the datasheet.\n\nKey specs: 1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC), 1000 V (AWM I/II A/B); 90 °C Dry, 90 °C Wet UL / -40 °C to +90 °C operating; 3 × 14 AWG (41×30) TC power conductors + 14 AWG TC ground + 1 pair 16 AWG (26×30) TC; 25 A per conductor at 30 °C (3 current-carrying conductors), 18 A per conductor for the pair (per NEC); overall diameter 0.820 in (20.8 mm); max pull tension 441 lbs (200 kg); min bend radius 9.8 in (250 mm) stationary and installation; weight 275 lbs/1000 ft (409 kg/km).\n\nApplications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations.\n\nmarking_code: null\npin_table: []\nabsolute_max_ratings: []
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
29511 Key Specifications
- Max Current
- 25 Amps per Conductor at 30 °C (3 Current Carrying Conductors); 18 Amps per Conductor at 30 °C for pair (per NEC)
- Voltage Rating
- 1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC), 1000 V (AWM I/II A/B)
- Temperature Rating
- 90 °C Dry, 90 °C Wet (UL); Operating -40 °C to +90 °C
- Cable Weight
- 275 lbs/1000 ft (409 kg/km)
- Conductors
- 3 × 14 AWG (41×30) tinned copper; 1 ground 14 AWG (41×30) TC; 1 pair 16 AWG (26×30) TC
- Max Pull Tension
- 441 lbs (200 kg)
- Min Bend Radius
- 9.8 in (250 mm) stationary; 9.8 in (250 mm) installation
- Overall Diameter
- 0.820 in (20.8 mm)
Characteristics (datasheet)
- Voltage Rating
- 1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC), 1000 V (AWM I/II A/B)
- Temperature Rating
- 90 °C Dry, 90 °C Wet (UL); Operating -40 °C to +90 °C
- Conductors
- 3 × 14 AWG (41×30) tinned copper; 1 ground 14 AWG (41×30) TC; 1 pair 16 AWG (26×30) TC
- Max Current
- 25 Amps per Conductor at 30 °C (3 Current Carrying Conductors); 18 Amps per Conductor at 30 °C for pair (per NEC)
- Overall Diameter
- 0.820 in (20.8 mm)
- Max Pull Tension
- 441 lbs (200 kg)
- Min Bend Radius
- 9.8 in (250 mm) stationary; 9.8 in (250 mm) installation
- Cable Weight
- 275 lbs/1000 ft (409 kg/km)
29511 Applications
- Variable Frequency Drives (VFD)
- AC Motor and Drive Systems
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 9261 — The Belden 9261 is a multi-conductor cable featuring 12 conductors of 20 AWG (7x...
- 79228 — The Belden / Alpha Wire 79228 is a 5-conductor, 14 AWG stranded tinned copper ca...
- 5491C — The Belden 5491C is a single-pair, 24 AWG tinned copper cable with semi-rigid PV...
- 9975 — The Belden 9975 is a low-temperature plastic lead wire featuring a 24 AWG solid...
- 25004 — The Belden 25004 is an XTRAGUARD 2 cable with four 22 AWG (7/30) tinned copper c...
- 934059706 — HIRSCHMANN TEST AND MEASUREMENT 934059706 Test Lead, 4mm Banana Plug to 4mm...
- 83347E — The 83347E is a high-temperature, 4-conductor, 26 AWG silver-plated copper cable...
- 6366 — The Belden 6366 is a multi-pair communication and control cable featuring six 24...
More Bulk Wire Cable
- 21657 — Belden 21657 is a 600 V Type TC/CIC power and control cable with three 8 AWG str...
- 78036 — The Belden 78036 is a 6-conductor, 22 AWG tinned copper ECOCABLE with modified p...
- 1069 — The Belden 1069 is a 9-conductor, 16 AWG stranded tinned copper communication an...
- 9448 — The Belden 9448 is a high-performance single-conductor coaxial cable featuring a...
- 9330 — The Belden 9330 is a high-performance instrumentation cable composed of four pai...
- 1801B — The Belden 1801B is a digital audio cable designed for interconnecting audio equ...
- 83953 — The Belden 83953 is a Type KX thermocouple cable featuring a single pair of 16 A...
- 8052 — The Belden 8052 is a 24 AWG solid bare copper magnet wire with PUR/Nylon insulat...
29511 FAQ
What is 29511?
29511 is a Bulk Wire Cable from Belden. Belden 29511 is a flexible 600 V/1000 V motor supply cable built for variable frequency drives (VFD) and AC motor and drive systems. It contains three 14 AWG tinned copper power conductors with XLPE insulation, a 14 AWG PVC ground wire (300% ground), an overall Beldfoil plus 85% tinned copper braid shield, and one separately foil-shielded 16 AWG control/brake pair under a black PVC jacket. It is rated 90 °C dry/wet, suitable for Class 1 Division 2 hazardous locations, and complies with TC-ER, UL Flexible Motor Supply Cable, and AWM I/II A/B requirements.\n\nIt is a cable assembly, so it has no pinout, no absolute maximum ratings table, and no top marking code listed in the datasheet.\n\nKey specs: 1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC), 1000 V (AWM I/II A/B); 90 °C Dry, 90 °C Wet UL / -40 °C to +90 °C operating; 3 × 14 AWG (41×30) TC power conductors + 14 AWG TC ground + 1 pair 16 AWG (26×30) TC; 25 A per conductor at 30 °C (3 current-carrying conductors), 18 A per conductor for the pair (per NEC); overall diameter 0.820 in (20.8 mm); max pull tension 441 lbs (200 kg); min bend radius 9.8 in (250 mm) stationary and installation; weight 275 lbs/1000 ft (409 kg/km).\n\nApplications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; Class 1 Division 2 Hazardous Locations.\n\nmarking_code: null\npin_table: []\nabsolute_max_ratings: [].
Who manufactures 29511?
29511 is manufactured by Belden.
Where can I download the 29511 datasheet PDF?
The 29511 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 29511 specifications
Click to ask a quick question:
Parameters
| Cable Weight | 275 lbs/1000 ft (409 kg/km) |
| Conductors | 3 × 14 AWG (41×30) tinned copper; 1 ground 14 AWG (41×30) TC; 1 pair 16 AWG (26×30) TC |
| Max Current | 25 Amps per Conductor at 30 °C (3 Current Carrying Conductors); 18 Amps per Conductor at 30 °C for pair (per NEC) |
| Max Pull Tension | 441 lbs (200 kg) |
| Min Bend Radius | 9.8 in (250 mm) stationary; 9.8 in (250 mm) installation |
| Overall Diameter | 0.820 in (20.8 mm) |
| Temperature Rating | 90 °C Dry, 90 °C Wet (UL); Operating -40 °C to +90 °C |
| Voltage Rating | 1000 V (UL Flexible Motor Supply Cable), 600 V (TC, C(UL) TC), 1000 V (AWM I/II A/B) |