28338A Datasheet
Belden 28338A is a UL Type TC (1277) power/control cable with four 16 AWG (7x24) bare copper conductors, PVC-nylon E2 insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), 90 °C dry/wet, sunlight resistant and suitable for direct burial, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations. No pinout or absolute maximum ratings apply because this is a bulk cable rather than a pin-based electronic component. It carries no separate top-side marking code in the datasheet. The stated applications are power and control applications up to 600 V and Class 1 Division 2 hazardous locations. Key specs include 4 x 16 AWG (7x24) bare copper conductors, PVC/nylon insulation at 0.020 in (0.51 mm), PVC jacket at 0.047 in (1.2 mm) with 0.331 in (8.41 mm) nominal diameter, 4.2 Ohm/1000ft nominal conductor DCR, 14.4 A max current per conductor at 30 °C, 140 lbs (64 kg) max pull tension, and 71 lbs/1000ft bulk weight. There is no Absolute Maximum Ratings table or pin-by-pin table in this document.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
28338A Key Specifications
- Nominal conductor DCR / max current
- 4.2 Ohm/1000ft; 14.4 Amps per conductor at 30 °C
- Voltage rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature rating
- 90 °C Dry, 90 °C Wet; operating -30 °C to 90 °C
- Conductor count / size / material
- 4 conductors, 16 AWG (7x24), bare copper
- Insulation
- PVC/Nylon (PVC + Nylon), 0.020 in (0.51 mm) nominal thickness
- Max pull tension / bulk weight
- 140 lbs (64 kg); 71 lbs/1000ft
- Outer jacket
- PVC, 0.047 in (1.2 mm) nominal thickness, 0.331 in (8.41 mm) nominal diameter
- Overall cable diameter
- 0.331 in (8.41 mm) nominal
Characteristics (datasheet)
- Conductor count / size / material
- 4 conductors, 16 AWG (7x24), bare copper
- Insulation
- PVC/Nylon (PVC + Nylon), 0.020 in (0.51 mm) nominal thickness
- Outer jacket
- PVC, 0.047 in (1.2 mm) nominal thickness, 0.331 in (8.41 mm) nominal diameter
- Overall cable diameter
- 0.331 in (8.41 mm) nominal
- Voltage rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature rating
- 90 °C Dry, 90 °C Wet; operating -30 °C to 90 °C
- Nominal conductor DCR / max current
- 4.2 Ohm/1000ft; 14.4 Amps per conductor at 30 °C
- Max pull tension / bulk weight
- 140 lbs (64 kg); 71 lbs/1000ft
28338A Applications
- Power and Control Applications up to 600V
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 70053 — The Belden 70053 is a 4-pair digital audio cable designed for professional studi...
- 8000 — The Belden 8000 is a 14 AWG (7x22) bare copper covered steel (BCCS) antenna wire...
- 8333 — The Belden 8333 is a computer EIA RS-232 cable featuring 3 pairs of 24 AWG stran...
- 50011L — The Belden 50011L is a single-pair RS-485 cable built with 24 AWG stranded tinne...
- 83264 — The Belden 83264 is a commercial, non-QPL Mil-Spec coaxial cable (RG-179 type) w...
- 934069102 — HIRSCHMANN TEST AND MEASUREMENT 934069102 Test Lead, 4mm Banana Plug to 4mm...
- 37190 — Belden 37190 is a 1/0 AWG (262x24) tinned copper lead wire with EPDM insulation,...
- 45468 — Belden part 45468 is an XTRAGUARD 4 cable with 8 conductors of 20 AWG (7x28) tin...
More Bulk Wire Cable
- 77254 — Belden 77254 is a 4-conductor, 28 AWG (7x36 stranded tinned copper) ECOCABLE wit...
- 9431 — The Belden 9431 is a multi-conductor electronic cable featuring 20 conductors ma...
- 85102 — The Belden 85102 is a high-temperature, chemical-resistant electronic cable feat...
- 86212 — The Belden 86212 is a 12-conductor, 24 AWG stranded tinned copper XTRAGUARD FLEX...
- 5902C — The Belden 5902C is a 2-pair, 22 AWG solid tinned copper conductor communication...
- 5932 — The part 5932 is an XTRAGUARD 1 shielded cable featuring two 28 AWG tinned coppe...
- 4306FE — The Belden 4306FE is an 8-conductor, 18 AWG stranded bare copper security and co...
- 6359 — The Belden 6359 is a 15-conductor communication and control cable featuring 24 A...
28338A FAQ
What is 28338A?
28338A is a Bulk Wire Cable from Belden. Belden 28338A is a UL Type TC (1277) power/control cable with four 16 AWG (7x24) bare copper conductors, PVC-nylon E2 insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), 90 °C dry/wet, sunlight resistant and suitable for direct burial, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations. No pinout or absolute maximum ratings apply because this is a bulk cable rather than a pin-based electronic component. It carries no separate top-side marking code in the datasheet. The stated applications are power and control applications up to 600 V and Class 1 Division 2 hazardous locations. Key specs include 4 x 16 AWG (7x24) bare copper conductors, PVC/nylon insulation at 0.020 in (0.51 mm), PVC jacket at 0.047 in (1.2 mm) with 0.331 in (8.41 mm) nominal diameter, 4.2 Ohm/1000ft nominal conductor DCR, 14.4 A max current per conductor at 30 °C, 140 lbs (64 kg) max pull tension, and 71 lbs/1000ft bulk weight. There is no Absolute Maximum Ratings table or pin-by-pin table in this document.
Who manufactures 28338A?
28338A is manufactured by Belden.
Where can I download the 28338A datasheet PDF?
The 28338A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 28338A specifications
Click to ask a quick question:
Parameters
| Conductor count / size / material | 4 conductors, 16 AWG (7x24), bare copper |
| Insulation | PVC/Nylon (PVC + Nylon), 0.020 in (0.51 mm) nominal thickness |
| Max pull tension / bulk weight | 140 lbs (64 kg); 71 lbs/1000ft |
| Nominal conductor DCR / max current | 4.2 Ohm/1000ft; 14.4 Amps per conductor at 30 °C |
| Outer jacket | PVC, 0.047 in (1.2 mm) nominal thickness, 0.331 in (8.41 mm) nominal diameter |
| Overall cable diameter | 0.331 in (8.41 mm) nominal |
| Temperature rating | 90 °C Dry, 90 °C Wet; operating -30 °C to 90 °C |
| Voltage rating | 600 V (TC-ER), 150 V (NPLF) |