28177A Datasheet
Belden 28177A is a UL Type TC (1277) power and control cable with three 4/0 AWG bare copper conductors plus one 4 AWG bare copper ground conductor, PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER), 90 °C dry and wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations. A recommended cable gland is Belden BTC200A1741RA.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
28177A Key Specifications
- Max. Current
- 260 Amps per Conductor at 30ºC (conductors); 95 Amps per Conductor at 30ºC (ground)
- Voltage Rating
- 600 V (TC-ER)
- Temperature Rating
- 90°C Dry, 90°C Wet; Wet/Dry: -30°C to 90°C
- Bulk Cable Weight
- 2525 lbs/1000ft
- Conductor(s)
- 3 x 4/0 AWG, 19x10 stranding, bare copper
- Ground
- 1 x 4 AWG, 7x12 stranding, bare copper
- Max. Pull Tension
- 8017.6 lbs (3636.7 kg)
- Nom. Outer Diameter
- 1.543 in (39.19 mm)
Characteristics (datasheet)
- Voltage Rating
- 600 V (TC-ER)
- Conductor(s)
- 3 x 4/0 AWG, 19x10 stranding, bare copper
- Ground
- 1 x 4 AWG, 7x12 stranding, bare copper
- Max. Current
- 260 Amps per Conductor at 30ºC (conductors); 95 Amps per Conductor at 30ºC (ground)
- Temperature Rating
- 90°C Dry, 90°C Wet; Wet/Dry: -30°C to 90°C
- Nom. Outer Diameter
- 1.543 in (39.19 mm)
- Max. Pull Tension
- 8017.6 lbs (3636.7 kg)
- Bulk Cable Weight
- 2525 lbs/1000ft
28177A Applications
- Power and Control Applications up to 600V
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 1885ELV — The 1885ELV is a Category 7 enhanced horizontal and building backbone cable feat...
- 7801A — The part 7801A is a discontinued metric video triax cable manufactured by Belden...
- 78405 — The Belden 78405 is an ECOCABLE featuring 20 conductors of 20 AWG tinned copper...
- 78118 — The Belden 78118 is an 8-conductor, 26 AWG tinned copper cable with modified pol...
- 77015 — The Belden 77015 is a high-performance 9-conductor, 20 AWG tinned copper control...
- 22635 — Belden 22635 is a Canadian Instrumentation Cable (TC-CIC) rated at 300 V, built...
- 76702TS — The Belden 76702TS is a high-flexibility multi-conductor cable from the MachFlex...
- 89728 — The Belden 89728 is a plenum-rated, 4-pair shielded cable designed for computer...
More Bulk Wire Cable
- 1672ATIN1000 — 1000ft 29AWG Coaxial Cable, Copper Conductor, TFE Dielectric, 75R Impedance
- 9829 — The Belden 9829 is a computer EIA RS-232/422 low-capacitance cable featuring two...
- 7783E — The Belden 7783E is a discontinued Triax 8 (RG-6, 18 AWG) coaxial cable featurin...
- 6413 — The Belden 6413 is a shielded, 2-pair 24 AWG tinned copper communication and con...
- 1294C — The Belden 1294C is a 4-conductor, 22 AWG tinned copper communication and contro...
- 6014C — The Belden 6014C is a shielded communication and control cable featuring 9 pairs...
- 9446 — The Belden 9446 is a single-conductor coaxial cable constructed with a 46 AWG si...
- 8620 — The Belden 8620 is a multi-conductor electronic cable featuring four 16 AWG tinn...
28177A FAQ
What is 28177A?
28177A is a Bulk Wire Cable from Belden. Belden 28177A is a UL Type TC (1277) power and control cable with three 4/0 AWG bare copper conductors plus one 4 AWG bare copper ground conductor, PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER), 90 °C dry and wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations. A recommended cable gland is Belden BTC200A1741RA.
Who manufactures 28177A?
28177A is manufactured by Belden.
Where can I download the 28177A datasheet PDF?
The 28177A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 28177A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 2525 lbs/1000ft |
| Conductor(s) | 3 x 4/0 AWG, 19x10 stranding, bare copper |
| Ground | 1 x 4 AWG, 7x12 stranding, bare copper |
| Max. Current | 260 Amps per Conductor at 30ºC (conductors); 95 Amps per Conductor at 30ºC (ground) |
| Max. Pull Tension | 8017.6 lbs (3636.7 kg) |
| Nom. Outer Diameter | 1.543 in (39.19 mm) |
| Temperature Rating | 90°C Dry, 90°C Wet; Wet/Dry: -30°C to 90°C |
| Voltage Rating | 600 V (TC-ER) |