29539
Belden 29539 is a 2000 V TC-ER / 1000 V WTTC flexible motor supply cable intended for Variable Frequency Drives (VFD), AC motor and drive systems, and high voltage applications. It uses three 8 AWG tinned copper power conductors plus one 8 AWG tinned copper ground conductor, with XLPE insulation, an overall Beldfoil/tinned copper braid shield, and a black PVC jacket. The cable is rated 90°C dry and wet, is suitable for indoor, outdoor, sunlight, oil resistant, and direct burial use, and meets TC-ER, WTTC, RHW-2, and CIC/TC compliance.
29501
Belden 29501 is a 600/1000 V flexible motor supply cable built for variable frequency drive and AC motor systems. It has three 14 AWG tinned copper phase conductors with XLPE insulation, a 300% ground arrangement (insulated and uninsulated 14 AWG grounds), and an overall foil-plus-braid shield with a black PVC jacket. It is rated TC-ER WTTC and is suitable for Class 1 Division 2 hazardous locations, indoor/outdoor use, sunlight resistance, and direct burial.\n","key_specs":["Conductors: 3 x 14 AWG 41x30 tinned copper phase; 1 x 14 AWG insulated ground; 1 x 14 AWG uninsulated ground","Insulation: XLPE 0.046 in (1.2 mm); conductor nominal diameter 0.173 in (4.39 mm)","Shield: Tri-Laminate (Alum+Poly+Alum) tape 100% plus tinned copper braid 85% with 14 AWG drainwire","Jacket: black PVC 0.073 in (1.9 mm); overall cable diameter 0.604 in (15.3 mm)","Voltage rating: 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC), 1000 V (AWM I/II A/B)","Temperature: UL 90°C Dry, 90°C Wet; operating -40°C To +90°C; installation -40C","Current: 25 Amps per Conductor at 30ºC (per NEC)","Mechanical: max pull tension 347 lbs (157 kg); weight 224 lbs/1000ft (333 kg/km); bend radius 6.0 in (150 mm) stationary, 7.2 in (180 mm) installation"],"absolute_max_ratings":[],"pin_table":[],"marking_code":null,"applications":["Variable Frequency Drives (VFD)","AC Motor and Drive Systems","Class 1 Division 2 Hazardous Locations"]}
29008
Belden part 29008 is a TC-ACIC Canadian instrumentation cable rated for 600 V power and control applications. It contains 30 bare copper 16 AWG conductors plus one 16 AWG ground wire, with XLPE insulation, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated for indoor, outdoor, sunlight-resistant, and burial use from -40 °C to +90 °C.
28627A
Belden 28627A is a 37-conductor, 16 AWG (7x24 stranded bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF) at 90 °C dry/wet, is sunlight resistant and suitable for direct burial, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
28611A
The Belden 28611A is a 25-conductor Type TC power and control cable with 18 AWG (7x26) bare copper conductors, PVC/nylon insulation, and a black PVC outer jacket with a ripcord. It is rated 600 V (TC-ER) and 150 V (NPLF) at 90 °C dry/wet, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
28324A
The Belden 28324A is a 25-conductor, 16 AWG (7x24 bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF) for operation from -30°C to 90°C in wet/dry conditions, and is approved for indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial installations. Listed applications include power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
28168A
The Belden 28168A is a UL Type TC (1277) power and control cable with three 1/0 AWG bare copper conductors plus one 6 AWG bare copper ground conductor. It features PVC/nylon insulation and a black PVC outer jacket, rated for 600 V and 90 °C dry/wet operation. It is suitable for indoor, outdoor, sunlight-resistant, and direct burial use, including Class 1 Division 2 hazardous locations.\n\n
28157A
Belden 28157A is a UL Type TC power and control cable with four 4 AWG bare copper conductors plus one 8 AWG bare copper ground wire, insulated with PVC/nylon and jacketed in black PVC. It is rated 600 V, 90°C dry and wet, and is suitable for indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial installations including Class 1 Division 2 hazardous locations.
28152A
The Belden 28152A is a UL Type TC (1277) tray cable with two 6 AWG bare copper conductors and one 8 AWG bare copper ground conductor, insulated with PVC/nylon and covered by a black PVC outer jacket. It is rated 600 V RMS (Type TC / TC-ER) for 90°C dry and 75°C wet service, with an operating temperature range of -25°C to +90°C. It is intended for harsh environments such as oil and gas extraction and refining sites, petrochemical facilities, and Profibus or Foundation FieldBus process automation, with suitability for direct burial, sunlight resistance, and exposure to moisture, dust, and oil.
28087A
The Belden 28087A is a 9-conductor, 14 AWG (7x22) bare copper power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with a nominal overall diameter of 0.499 in (12.7 mm).
28086A
Belden 28086A is an 8-conductor, 14 AWG (7x22 bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry/wet, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations, with sunlight resistance and direct-burial suitability. The cable has no overall shield, includes a ripcord, and has a nominal overall diameter of 0.465 in.
28084A
Belden 28084A is a 6-conductor UL Type TC power and control cable with 14 AWG (7x22) bare copper conductors, PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with an operating temperature of -30°C to 90°C wet/dry. The cable is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
28083A
The Belden 28083A is a 5-conductor 14 AWG (7x22 bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF) and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
28082A
The Belden 28082A is a UL Type TC (1277) power and control cable with four 14 AWG (7x22) bare copper conductors, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations.
27916A
The Belden 27916A is a 2-conductor 18 AWG (7x26 bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC) / 150 V (NPLF) at 90 °C wet/dry and is intended for power and control applications up to 600 V, including indoor, outdoor, sunlight-resistant, and direct burial use.
27636A
Belden 27636A is a UL Type TC (1277) power and control cable with two 14 AWG (7x22) bare copper conductors, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC) / 150 V (NPLF), 90 °C wet/dry, and is suitable for indoor, outdoor, sunlight-resistant, and direct burial use, including Class 1 Division 2 hazardous locations.
27152A
The Belden 27152A is a UL Type TC power and control cable with two 6 AWG bare copper conductors and one 8 AWG bare copper ground wire, insulated with PVC/nylon and jacketed in black PVC. It is rated for 600 V and 90 °C dry / 75 °C wet operation and is suitable for indoor, outdoor, sunlight-resistant, and direct burial installations, including Class 1 Division 2 hazardous locations. The cable has no outer shield and includes a ripcord in the jacket.
27087A
Belden 27087A is a 9-conductor 14 AWG (7x22) bare copper control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V RMS (Type TC) and 150 V RMS (NPLF) and is intended for industrial control, raceways, cable trays and ducts, digital control instruments, encoders, solenoids, valves, actuators, and positioners.
27085A
Belden 27085A is a 7-conductor, 14 AWG (7x22) bare copper cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V RMS as Type TC and 150 V RMS as NPLF, and is suitable for indoor, outdoor, sunlight-resistant, and direct-burial installations. It is intended for industrial control, raceways, cable trays, digital control, instruments, solenoids, valves, actuators, and positioners.
27082A
The Belden 27082A is a UL Type TC (1277) power and control cable with four 14 AWG bare copper conductors (7x22 stranding). It has PVC/nylon insulation, a black PVC outer jacket with ripcord, and is rated 600 V (TC) / 150 V (NPLF) for 90°C dry / 75°C wet operation, with sunlight resistance and direct burial suitability.