27152A Datasheet
The Belden 27152A is a UL Type TC power and control cable with two 6 AWG bare copper conductors and one 8 AWG bare copper ground wire, insulated with PVC/nylon and jacketed in black PVC. It is rated for 600 V and 90 °C dry / 75 °C wet operation and is suitable for indoor, outdoor, sunlight-resistant, and direct burial installations, including Class 1 Division 2 hazardous locations. The cable has no outer shield and includes a ripcord in the jacket.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
27152A Key Specifications
- Conductor DCR and current rating
- 0.42 Ohm/1000ft; 75 Amps per Conductor at 30ºC
- Ground wire DCR and current rating
- 0.67 Ohm/1000ft (2.2 Ohm/km); 55 Amps per Conductor at 30ºC
- UL voltage rating
- 600 V
- Temperature rating
- 90°C Dry, 75°C Wet; Wet/Dry: -30°C To 90°C
- Conductor / ground wire size and stranding
- 2 conductors 6 AWG 7x14 bare copper; 1 ground wire 8 AWG 7x16 bare copper
- Insulation material and thickness
- PVC/Nylon; 0.035 in (0.89 mm) nominal thickness
- Jacket material, thickness, and overall diameter
- Black PVC; 0.063 in (1.6 mm) nominal thickness; 0.630 in overall diameter
- Max pull tension and bulk weight
- 914 lbs (415 kg); 316 lbs/1000ft
Characteristics (datasheet)
- Conductor / ground wire size and stranding
- 2 conductors 6 AWG 7x14 bare copper; 1 ground wire 8 AWG 7x16 bare copper
- Insulation material and thickness
- PVC/Nylon; 0.035 in (0.89 mm) nominal thickness
- Jacket material, thickness, and overall diameter
- Black PVC; 0.063 in (1.6 mm) nominal thickness; 0.630 in overall diameter
- UL voltage rating
- 600 V
- Temperature rating
- 90°C Dry, 75°C Wet; Wet/Dry: -30°C To 90°C
- Conductor DCR and current rating
- 0.42 Ohm/1000ft; 75 Amps per Conductor at 30ºC
- Ground wire DCR and current rating
- 0.67 Ohm/1000ft (2.2 Ohm/km); 55 Amps per Conductor at 30ºC
- Max pull tension and bulk weight
- 914 lbs (415 kg); 316 lbs/1000ft
27152A Applications
- Power and Control Applications up to 600V
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 9159 — The Belden 9159 is a 5-pair 18 AWG tinned copper electronic cable with PVC insul...
- 29726C — The Belden 29726C is a 3-conductor VFD power cable using 4 AWG (7x12) bare coppe...
- 77211 — The Belden 77211 is a multi-conductor ECOCABLE featuring 12 conductors of 20 AWG...
- 86603CY — The Belden 86603CY is an XTRAGUARD FLEX continuous flex data cable with three 24...
- 1852 — The Belden 1852 is a single-conductor 28 AWG tinned copper hook-up wire with PVC...
- 80135 — The Belden 80135 (ECOFLEX PUR) is a 5-conductor, 18 AWG stranded tinned copper c...
- 5021C — The Belden 5021C is a XTRAGUARD 1, single-pair 22 AWG stranded tinned copper cab...
- 79009FF — The Belden 79009FF is a Safe-T-Line fire-resistant multi-conductor cable featuri...
More Bulk Wire Cable
- 58124 — The Belden 58124 is a plenum-rated communication and control cable featuring fou...
- 65825 — The Belden 65825 is a 25-conductor, 18 AWG bare copper XTRAGUARD FLEX flexible c...
- 8333 — The Belden 8333 is a computer EIA RS-232 cable featuring 3 pairs of 24 AWG stran...
- 76104WS — The 76104WS is a MachFlex™ high-flex 4-conductor 26 AWG tinned copper cable with...
- 8208 — The Belden 8208 is a 2-conductor 18 AWG tinned copper cable with EPDM insulation...
- 78341 — The Belden 78341 ECOCABLE is a high-performance multi-conductor cable featuring...
- 1037A — The 1037A is a black-jacketed instrumentation cable designed for industrial cont...
- 9489 — The Belden 9489 is a high-performance instrumentation cable featuring one pair o...
27152A FAQ
What is 27152A?
27152A is a Bulk Wire Cable from Belden. The Belden 27152A is a UL Type TC power and control cable with two 6 AWG bare copper conductors and one 8 AWG bare copper ground wire, insulated with PVC/nylon and jacketed in black PVC. It is rated for 600 V and 90 °C dry / 75 °C wet operation and is suitable for indoor, outdoor, sunlight-resistant, and direct burial installations, including Class 1 Division 2 hazardous locations. The cable has no outer shield and includes a ripcord in the jacket.
Who manufactures 27152A?
27152A is manufactured by Belden.
Where can I download the 27152A datasheet PDF?
The 27152A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 27152A specifications
Click to ask a quick question:
Parameters
| Conductor DCR and current rating | 0.42 Ohm/1000ft; 75 Amps per Conductor at 30ºC |
| Conductor / ground wire size and stranding | 2 conductors 6 AWG 7x14 bare copper; 1 ground wire 8 AWG 7x16 bare copper |
| Ground wire DCR and current rating | 0.67 Ohm/1000ft (2.2 Ohm/km); 55 Amps per Conductor at 30ºC |
| Insulation material and thickness | PVC/Nylon; 0.035 in (0.89 mm) nominal thickness |
| Jacket material, thickness, and overall diameter | Black PVC; 0.063 in (1.6 mm) nominal thickness; 0.630 in overall diameter |
| Max pull tension and bulk weight | 914 lbs (415 kg); 316 lbs/1000ft |
| Temperature rating | 90°C Dry, 75°C Wet; Wet/Dry: -30°C To 90°C |
| UL voltage rating | 600 V |