28627A Datasheet
Belden 28627A is a 37-conductor, 16 AWG (7x24 stranded bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF) at 90 °C dry/wet, is sunlight resistant and suitable for direct burial, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
28627A Key Specifications
- Max current
- 7.2 Amps per Conductor at 30ºC
- Voltage rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature rating
- 90°C Dry, 90°C Wet; Wet/Dry: -30°C to 90°C
- Bulk cable weight
- 498 lbs/1000ft
- Conductors
- 37 x 16 AWG, 7x24 stranded bare copper
- Max pull tension
- 1320.9 lbs (599.15 kg)
- Nominal conductor DCR
- 4.45 Ohm/1000ft
- Overall cable diameter (nominal)
- 0.812 in (20.6 mm)
Characteristics (datasheet)
- Conductors
- 37 x 16 AWG, 7x24 stranded bare copper
- Nominal conductor DCR
- 4.45 Ohm/1000ft
- Max current
- 7.2 Amps per Conductor at 30ºC
- Voltage rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature rating
- 90°C Dry, 90°C Wet; Wet/Dry: -30°C to 90°C
- Overall cable diameter (nominal)
- 0.812 in (20.6 mm)
- Max pull tension
- 1320.9 lbs (599.15 kg)
- Bulk cable weight
- 498 lbs/1000ft
28627A Applications
- Power and Control Applications up to 600V
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 76325WS — The Belden 76325WS is a MachFlex™ high-flexibility 25-conductor cable featuring...
- 75031 — The Belden 75031 is a high-flex Category 5e SF/UTP cable featuring two 24 AWG ti...
- 934066705 — HIRSCHMANN TEST AND MEASUREMENT 934066705 Test Lead, 4mm Banana Plug to 4mm...
- 8883MN — The 8883MN is a SpaceMaker™ 7-conductor 22 AWG tinned copper cable with polyprop...
- 1118A — The Belden 1118A is a UL-listed instrumentation cable featuring a single pair of...
- 5683 — The Belden 5683 is a 3-conductor, 26 AWG tinned copper cable with semi-rigid PVC...
- 8691 — The Belden 8691 is an electronic cable consisting of six pairs of 18 AWG tinned...
- 79120 — The Belden 79120 is a multi-conductor shielded cable featuring seven 16 AWG stra...
More Bulk Wire Cable
- 82641 — The Belden 82641 is a plenum-rated, 1-pair RS-232 cable designed for computer co...
- 86225CY — The Belden 86225CY is a 25-conductor, 24 AWG tinned copper XTRAGUARD FLEX contin...
- 8897 — The Belden 8897 is a low-temperature rubber lead wire featuring an 18 AWG (65x36...
- 8910 — The Belden 8910 is a low-temperature plastic lead wire featuring a 10 AWG tinned...
- 70102E — The Belden 70102E is a Profibus DP cable designed for data transmission in instr...
- 50983 — The Belden 50983 is a low loss triple shield flexible coaxial cable designed for...
- 5313C — The Belden 5313C is a 15-conductor, 22 AWG tinned copper XTRAGUARD 1 shielded ca...
- 26320FL — Belden 26320FL is an armored plenum-rated fire alarm cable (FPLP) with two 18 AW...
28627A FAQ
What is 28627A?
28627A is a Bulk Wire Cable from Belden. Belden 28627A is a 37-conductor, 16 AWG (7x24 stranded bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF) at 90 °C dry/wet, is sunlight resistant and suitable for direct burial, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
Who manufactures 28627A?
28627A is manufactured by Belden.
Where can I download the 28627A datasheet PDF?
The 28627A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 28627A specifications
Click to ask a quick question:
Parameters
| Bulk cable weight | 498 lbs/1000ft |
| Conductors | 37 x 16 AWG, 7x24 stranded bare copper |
| Max current | 7.2 Amps per Conductor at 30ºC |
| Max pull tension | 1320.9 lbs (599.15 kg) |
| Nominal conductor DCR | 4.45 Ohm/1000ft |
| Overall cable diameter (nominal) | 0.812 in (20.6 mm) |
| Temperature rating | 90°C Dry, 90°C Wet; Wet/Dry: -30°C to 90°C |
| Voltage rating | 600 V (TC-ER), 150 V (NPLF) |