Belden Datasheets

4,717 datasheets

Bulk Wire Cable

1046A

The Belden 1046A is a 36-pair UL-listed instrumentation cable featuring 16 AWG (7x24) bare copper conductors with PVC-nylon insulation (ICEA Chart E1 color code), individual and overall Beldfoil shields, and a black PVC outer jacket. It supports 600V TC-ER and 150V NPLF voltage ratings with operating temperatures of 90°C dry and 75°C wet. This cable is designed for industrial control, digital control, instrumentation, solenoids, valves, and PLC systems in raceways, ducts, or direct burial applications.

Bulk Wire Cable
24 2

1047A

The Belden 1047A is a 50-pair UL instrumentation cable featuring 16 AWG bare copper conductors with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It has a voltage rating of 600V TC-ER and 150V NPLF, with a temperature rating of 90°C dry and 75°C wet. It is designed for use in industrial control systems, digital control, instruments, solenoids, valves, actuators, and programmable logic controllers (PLCs).

Bulk Wire Cable
28 4

1048A

The Belden 1048A is a UL-listed instrumentation cable consisting of two 18 AWG stranded bare copper pairs with PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, and is suitable for use in dry, wet, and buried environments with sunlight resistance. This cable is designed for industrial control systems, digital instruments, PLCs, solenoids, valves, and actuators.

Bulk Wire Cable
30 2

1049A

The Belden 1049A is a UL-listed instrumentation cable with four 18 AWG bare copper pairs, PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, and is designed for use in harsh or outdoor environments (sunlight, wet, burial). It is primarily used for industrial control, instrumentation (4-20mA, 0-10V), DCS, PLC systems, and connecting solenoids, valves, actuators, and positioners.

Bulk Wire Cable
25 2

1050A

The Belden 1050A is an 8-pair, 18 AWG bare copper instrumentation cable with PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, supporting an operating temperature range of -30°C to 90°C in dry and wet environments. This cable is designed for industrial control, low-voltage digital control, instrumentation, and process automation systems.

Bulk Wire Cable
22 2

1051A

The Belden 1051A is a UL-listed instrumentation and control cable featuring 12 pairs of 18 AWG stranded bare copper conductors with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, with an operating temperature range of -30°C to 90°C dry and 75°C wet. This cable is designed for use in industrial control systems, raceways, DCS, PLCs, and for connecting solenoids, valves, actuators, and positioners.

Bulk Wire Cable
23 2

1052A

The Belden 1052A is a UL-listed instrumentation cable consisting of 16 pairs of 18AWG stranded bare copper conductors with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, with an operating temperature range of -30°C to 90°C dry/wet. This cable is designed for industrial control, DCS, PLC systems, solenoids, valves, and actuators in indoor, outdoor, burial, and sunlight-resistant environments.

Bulk Wire Cable
27 2

1053A

The Belden 1053A is a 24-pair, 18 AWG bare copper instrumentation cable with PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, with an operating temperature range of -30°C to 90°C dry/wet. It is designed for industrial control, digital instruments, and distributed control systems (DCS).

Bulk Wire Cable
24 5

1054A

The Belden 1054A is a UL instrumentation cable consisting of 36 pairs of 18 AWG (7x26) bare copper conductors with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, with an operating temperature range of 90°C dry and 75°C wet. This cable is suitable for industrial control, raceways, digital control, instruments, solenoids, valves, actuators, and positioners.

Bulk Wire Cable
31 2

1055A

The Belden 1055A is a UL-listed instrumentation cable featuring two 16 AWG bare copper pairs with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It supports a voltage rating of 600V TC-ER and 150V NPLF, and can handle up to 14 Amps per conductor at 30°C. This cable is designed for industrial control, low-voltage digital control, instrumentation, and automation systems in harsh indoor, outdoor, and buried environments.

Bulk Wire Cable
26 4

1056A

The Belden 1056A is a UL-listed instrumentation and control cable featuring 4 pairs of 20 AWG and one 22 AWG bare copper conductors with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is designed for use in industrial control systems, DCS, PLCs, solenoids, valves, actuators, and low-voltage digital control circuits. The cable is rated for 300 V (PLTC/CMG) / 150 V (ITC) and operates reliably within a temperature range of -30°C to +105°C.

Bulk Wire Cable
26 2

1057A

The Belden 1057A is an instrumentation and control cable featuring eight 20 AWG pairs and one 22 AWG comm wire with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for 300V (PLTC/CMG/AWM 2464) and 150V (ITC) with an operating temperature range of -30°C to +105°C. This cable is designed for use in industrial control, digital control, DCS, PLC systems, and instrumentation applications such as solenoids, valves, and actuators.

Bulk Wire Cable
28 2

1058A

The Belden 1058A is a UL-listed instrumentation cable featuring 12 pairs of 20 AWG and one 22 AWG bare copper conductors with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for 300V (PLTC, CMG, AWM 2464) and 150V (ITC), with an operating temperature range of -30°C to +105°C. This cable is designed for industrial control, raceways, digital control, instruments (4-20ma, 0-10v), encoders, solenoids, valves, actuators, and PLCs.

Bulk Wire Cable
25 2

1059A

The Belden 1059A is an UL-listed instrumentation cable consisting of 16 pairs of 20 AWG and one 22 AWG bare copper conductors with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for 300V (CMG/PLTC) and 150V (ITC), and is suitable for use in industrial control, low voltage digital control, DCS, PLC systems, solenoids, valves, actuators, and positioners in harsh environments with an operating temperature range of -30°C to +105°C.

Bulk Wire Cable
23 2

1060A

The Belden 1060A is a multi-conductor instrumentation cable featuring 24 pairs of 20 AWG bare copper conductors and a single 22 AWG comm wire, all insulated with PVC. It includes an overall Beldfoil shield with a bare copper drain wire and a black PVC outer jacket, rated up to 300V for PLTC and ITC applications. This cable is designed for use in industrial control systems, DCS, PLCs, and low-voltage digital control circuits operating in harsh environments.

Bulk Wire Cable
29 2

1061A

The Belden 1061A is a 36-pair instrumentation and control cable featuring 20 AWG and 22 AWG bare copper conductors with PVC insulation, an overall Beld foil shield, and a black PVC outer jacket. It is rated for 300V PLTC and ITC applications with an operating temperature range of -30°C to +105°C. This cable is designed for use in industrial control systems, raceways, cable trays, DCS, PLCs, and connecting instruments, encoders, solenoids, valves, and actuators.

Bulk Wire Cable
26 1

1062A

The Belden 1062A is a UL-listed instrumentation cable featuring 50 pairs of 20 AWG and one 22 AWG bare copper conductors, PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for 300V (PLTC/CMG) and 150V (ITC) with an operating temperature range of -30 °C to +105 °C. This cable is designed for industrial control, digital instruments, DCS, PLC systems, and solenoid/valve actuator connections in harsh environments.

Bulk Wire Cable
27 2

1063A

The Belden 1063A is a UL-listed instrumentation cable consisting of two 18 AWG bare copper pairs with PVC-nylon insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, with an operating temperature range of -30°C to 90°C dry/wet. This cable is designed for industrial control, DCS, PLC, solenoid, valve, and low-voltage digital control applications in harsh indoor and outdoor environments.

Bulk Wire Cable
24 2

1064

The Belden 1064 is a communication and control cable consisting of 4 conductors of 16 AWG stranded tinned copper with PVC insulation and a slate PVC outer jacket. It is rated for a UL voltage of 600 V (AWM 2463) and an operating temperature range of -20°C to +80°C. This cable is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and automation equipment.

Bulk Wire Cable
25 4

1065

The Belden 1065 is a 5-conductor, 16 AWG tinned copper control cable with PVC insulation and a slate PVC outer jacket, rated for 600 V and operating temperatures from -20°C to +80°C. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, automation equipment, and instrumentation systems.

Bulk Wire Cable
24 1