1055A Datasheet
The Belden 1055A is a UL-listed instrumentation cable featuring two 16 AWG bare copper pairs with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It supports a voltage rating of 600V TC-ER and 150V NPLF, and can handle up to 14 Amps per conductor at 30°C. This cable is designed for industrial control, low-voltage digital control, instrumentation, and automation systems in harsh indoor, outdoor, and buried environments.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1055A Key Specifications
- Max. Current
- 14 Amps per conductor @ 30°C
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Operating Temperature
- -30°C to 90°C Dry/Wet (UL 90°C Dry, 90°C Wet)
- Conductor
- 2 pairs 16 AWG (7x24) Bare Copper (BC)
- Nom. Conductor DCR
- 4.2 Ohm/1000ft
- Nom. Inner Shield DCR
- 5.49 Ohm/1000ft (18.0 Ohm/km)
- Nom Outer Shield DCR
- 3.24 Ohm/1000ft (10.6 Ohm/km)
- Overall Cable Diameter (Nominal)
- 0.475 in (12.1 mm)
Characteristics (datasheet)
- Conductor
- 2 pairs 16 AWG (7x24) Bare Copper (BC)
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Max. Current
- 14 Amps per conductor @ 30°C
- Nom. Conductor DCR
- 4.2 Ohm/1000ft
- Nom. Inner Shield DCR
- 5.49 Ohm/1000ft (18.0 Ohm/km)
- Nom Outer Shield DCR
- 3.24 Ohm/1000ft (10.6 Ohm/km)
- Operating Temperature
- -30°C to 90°C Dry/Wet (UL 90°C Dry, 90°C Wet)
- Overall Cable Diameter (Nominal)
- 0.475 in (12.1 mm)
1055A Applications
- Industrial control
- Raceways, cable trays and ducts
- Digital control
- Instruments (4-20ma, 0-10v)
- Low voltage digital control (24v)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids
- Valves
- Actuators
- Positioners
Other Belden parts
- 78372 — The Belden 78372 is an ECOCABLE featuring 2 pairs of 24 AWG stranded tinned copp...
- 86205 — The Belden 86205 is a 5-conductor, 24 AWG tinned copper cable with semi-rigid PV...
- 77135 — The Belden 77135 is a 4-conductor 16 AWG tinned copper ECOCABLE with mPPE insula...
- 1776 — The Belden 1776 is a discontinued 2-conductor 20 AWG microphone cable designed f...
- 27152A — The Belden 27152A is a UL Type TC power and control cable with two 6 AWG bare co...
- 78043 — The Belden 78043 is an ECOCABLE multi-conductor cable featuring three 20 AWG tin...
- 8690 — The Belden 8690 is a 3-pair 18 AWG tinned copper cable with PVC insulation and a...
- 8102 — The Belden 8102 is a computer EIA RS-232/422 low-capacitance cable designed for...
More Bulk Wire Cable
- 5698 — The Belden 5698 is a shielded multi-pair cable (XTRAGUARD 1) consisting of 5 pai...
- 9764 — The Belden 9764 is an RG11 type CATV video coaxial cable featuring a 14 AWG soli...
- 58414 — The Belden 58414 is a plenum-rated, overall shielded communication and control c...
- 6402FE — The Belden 6402FE is a plenum-rated (CMP) security and sound cable featuring fou...
- 3312 — The Belden 3312 is a 12-conductor, 28 AWG tinned copper communication and contro...
- 76302WS — The 76302WS is a MachFlex™ high-flexibility 2-conductor cable rated for 300 V, d...
- 5098C — The 5098C is an 8-conductor, 24 AWG tinned copper cable with semi-rigid PVC insu...
- 8668 — The Belden 8668 is a tinned copper braid conductor with a size of 13.3 AWG (120x...
1055A FAQ
What is 1055A?
1055A is a Bulk Wire Cable from Belden. The Belden 1055A is a UL-listed instrumentation cable featuring two 16 AWG bare copper pairs with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It supports a voltage rating of 600V TC-ER and 150V NPLF, and can handle up to 14 Amps per conductor at 30°C. This cable is designed for industrial control, low-voltage digital control, instrumentation, and automation systems in harsh indoor, outdoor, and buried environments.
Who manufactures 1055A?
1055A is manufactured by Belden.
Where can I download the 1055A datasheet PDF?
The 1055A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1055A specifications
Click to ask a quick question:
Parameters
| Conductor | 2 pairs 16 AWG (7x24) Bare Copper (BC) |
| Max. Current | 14 Amps per conductor @ 30°C |
| Nom. Conductor DCR | 4.2 Ohm/1000ft |
| Nom. Inner Shield DCR | 5.49 Ohm/1000ft (18.0 Ohm/km) |
| Nom Outer Shield DCR | 3.24 Ohm/1000ft (10.6 Ohm/km) |
| Operating Temperature | -30°C to 90°C Dry/Wet (UL 90°C Dry, 90°C Wet) |
| Overall Cable Diameter (Nominal) | 0.475 in (12.1 mm) |
| Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |