1049A Datasheet
The Belden 1049A is a UL-listed instrumentation cable with four 18 AWG bare copper pairs, PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, and is designed for use in harsh or outdoor environments (sunlight, wet, burial). It is primarily used for industrial control, instrumentation (4-20mA, 0-10V), DCS, PLC systems, and connecting solenoids, valves, actuators, and positioners.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1049A Key Specifications
- Max Current
- 10 Amps per conductor @ 30°C
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Operating Temperature
- -30°C to 90°C Dry/Wet (UL 90°C Dry, 90°C Wet)
- Bulk Cable Weight
- 122 lbs/1000ft
- Conductor
- 4 pairs, 18 AWG (7x26) bare copper (BC)
- Max Pull Tension
- 214 lbs (97.1 kg)
- Overall Cable Diameter
- 0.493 in (12.5 mm) nominal
- Shielding
- Individual & overall Bi-Laminate (Alum+Poly) tape, 100% coverage, with 20 AWG inner / 18 AWG outer TC drain wires
Characteristics (datasheet)
- Conductor
- 4 pairs, 18 AWG (7x26) bare copper (BC)
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Max Current
- 10 Amps per conductor @ 30°C
- Operating Temperature
- -30°C to 90°C Dry/Wet (UL 90°C Dry, 90°C Wet)
- Overall Cable Diameter
- 0.493 in (12.5 mm) nominal
- Shielding
- Individual & overall Bi-Laminate (Alum+Poly) tape, 100% coverage, with 20 AWG inner / 18 AWG outer TC drain wires
- Max Pull Tension
- 214 lbs (97.1 kg)
- Bulk Cable Weight
- 122 lbs/1000ft
1049A Applications
- Industrial control
- Raceways cable trays and ducts
- Digital control
- Instruments (4-20mA, 0-10V)
- Low voltage digital control (24V, ...)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids, valves, actuators, positioners
Other Belden parts
- 29552C — The Belden 29552C is a CSA Type TC VFD power cable built for variable frequency...
- 2102A — The Belden 2102A is a high-performance fieldbus cable featuring five 18AWG tinne...
- 934061709 — HIRSCHMANN TEST AND MEASUREMENT 934061709 Test Lead, 4mm Banana Plug to 4mm...
- 5492C — The Belden 5492C is a XTRAGUARD 1 shielded multi-conductor cable featuring 2 pai...
- 3112A — The Belden 3112A is a Type KX thermocouple cable containing a single pair of 20...
- 45092 — Belden 45092 is an XTRAGUARD 4 two-conductor 24 AWG (7x32 tinned copper) cable w...
- 89259 — The Belden 89259 is a 75 Ohm analog video coaxial cable of RG-59 type, built wit...
- 2432 — The Belden 2432 is a discontinued Category 6+ Enhanced Premise Horizontal Cable...
More Bulk Wire Cable
- 6208C — The Belden 6208C is an 8-pair, 24 AWG tinned copper communication and control ca...
- 74009 — The Belden 74009 is a Category 5e horizontal cable consisting of 4 pairs of 22 A...
- 3130A — The Belden 3130A is a heavy-duty UL instrumentation cable featuring 36 triads of...
- 6363 — The Belden 6363 is a multi-pair communication and control cable designed for low...
- 45291 — Belden 45291 is an XTRAGUARD 4 single-pair, 20 AWG stranded tinned copper cable...
- 55492 — The Belden 55492 is a XTRAGUARD 5 shielded cable featuring two 24 AWG tinned cop...
- 7057 — The Belden 7057 is a single-conductor hook-up wire with an 18 AWG tinned copper...
- 6642 — The Belden 6642 is a 2-conductor, 20 AWG tinned copper communication and control...
1049A FAQ
What is 1049A?
1049A is a Bulk Wire Cable from Belden. The Belden 1049A is a UL-listed instrumentation cable with four 18 AWG bare copper pairs, PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, and is designed for use in harsh or outdoor environments (sunlight, wet, burial). It is primarily used for industrial control, instrumentation (4-20mA, 0-10V), DCS, PLC systems, and connecting solenoids, valves, actuators, and positioners.
Who manufactures 1049A?
1049A is manufactured by Belden.
Where can I download the 1049A datasheet PDF?
The 1049A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1049A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 122 lbs/1000ft |
| Conductor | 4 pairs, 18 AWG (7x26) bare copper (BC) |
| Max Current | 10 Amps per conductor @ 30°C |
| Max Pull Tension | 214 lbs (97.1 kg) |
| Operating Temperature | -30°C to 90°C Dry/Wet (UL 90°C Dry, 90°C Wet) |
| Overall Cable Diameter | 0.493 in (12.5 mm) nominal |
| Shielding | Individual & overall Bi-Laminate (Alum+Poly) tape, 100% coverage, with 20 AWG inner / 18 AWG outer TC drain wires |
| Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |