1051A Datasheet

BeldenBulk Wire Cable

The Belden 1051A is a UL-listed instrumentation and control cable featuring 12 pairs of 18 AWG stranded bare copper conductors with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, with an operating temperature range of -30°C to 90°C dry and 75°C wet. This cable is designed for use in industrial control systems, raceways, DCS, PLCs, and for connecting solenoids, valves, actuators, and positioners.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

1051A Key Specifications

Voltage Rating
600 V (TC-ER), 150 V (NPLF)
UL Temperature Operating
90°C Dry, 90°C Wet -30C to 90C Dry, 75C wet
Bulk Cable Weight
331 lbs/1000ft
Conductor
12 Pair(s) 18 AWG 7x26 BC - Bare Copper
Max. Pull Tension
728 lbs (330 kg)
Min. Bend Radius (Stationary / Installation)
9.4 in (240 mm)
Nom. Conductor DCR
5.86 Ohm/1000ft (19.2 Ohm/km)
Nominal Outer Diameter
0.785 in (19.9 mm)

Characteristics (datasheet)

Conductor
12 Pair(s) 18 AWG 7x26 BC - Bare Copper
Voltage Rating
600 V (TC-ER), 150 V (NPLF)
UL Temperature Operating
90°C Dry, 90°C Wet -30C to 90C Dry, 75C wet
Nominal Outer Diameter
0.785 in (19.9 mm)
Nom. Conductor DCR
5.86 Ohm/1000ft (19.2 Ohm/km)
Nom Outer Shield DCR
4.22 Ohm/1000ft (13.8 Ohm/km)
Min. Bend Radius (Stationary / Installation)
9.4 in (240 mm)
Max. Pull Tension
728 lbs (330 kg)
Bulk Cable Weight
331 lbs/1000ft

1051A Applications

  • Industrial Control
  • Raceways Cable trays and ducts
  • Digital Control
  • Instruments (4-20ma, 0-10v)
  • Low voltage digital control (24v)
  • Encoders
  • Control circuits
  • Distributed control system (DCS)
  • Programmable logic controller (PLC)
  • Solenoids, Valves, Actuators, Positioners

Other Belden parts

  • 74046NH — The Belden 74046NH is a DataTuff Industrial Single Pair Ethernet (SPE) cable des...
  • 76007WS — The Belden 76007WS is a highly flexible, shielded 7-conductor cable designed for...
  • 79245 — The Belden 79245 is a 3-conductor, 22 AWG tinned copper cable with mPPE insulati...
  • 83320E — The 83320E is a high-temperature, 2-conductor 20 AWG silver-plated copper cable...
  • 45162 — Belden part 45162 is a 2-conductor 18 AWG (16x30 stranded tinned copper) XTRAGUA...
  • 21600 — The Belden 21600 is a 600 V Type TC/CIC power and control cable with two 10 AWG...
  • 65012 — The Belden 65012 is an XTRAGUARD FLEX flexible control cable featuring 12 conduc...
  • 5103C — The Belden 5103C is a 3-conductor, 22 AWG tinned copper cable with semi-rigid PV...

More Bulk Wire Cable

  • 8875MN — The Belden 8875MN is a SpaceMaker™ shielded cable consisting of two 18 AWG tinne...
  • 6386 — The Belden 6386 is a shielded communication and control cable featuring 6 pairs...
  • 80043 — The Belden 80043 (ECOFLEX PUR) is a halogen-free, 4-conductor 16 AWG tinned copp...
  • 27153A — Belden 27153A is a UL Type TC (1277) power and control cable with three 6 AWG ba...
  • 78328 — The Belden 78328 is an 8-conductor, 24 AWG stranded tinned copper cable with mod...
  • 28615A — Belden 28615A is a UL Type TC (1277) power and control cable with 6 conductors o...
  • 1633E — The Belden 1633E is a Category 5e F/UTP horizontal and backbone cable featuring...
  • 7962A — The Belden 7962A is an industrial Ethernet Cat 5e cable featuring a quad (two-pa...

1051A FAQ

What is 1051A?

1051A is a Bulk Wire Cable from Belden. The Belden 1051A is a UL-listed instrumentation and control cable featuring 12 pairs of 18 AWG stranded bare copper conductors with PVC-nylon insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, with an operating temperature range of -30°C to 90°C dry and 75°C wet. This cable is designed for use in industrial control systems, raceways, DCS, PLCs, and for connecting solenoids, valves, actuators, and positioners.

Who manufactures 1051A?

1051A is manufactured by Belden.

Where can I download the 1051A datasheet PDF?

The 1051A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 1051A specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk Cable Weight331 lbs/1000ft
Conductor12 Pair(s) 18 AWG 7x26 BC - Bare Copper
Max. Pull Tension728 lbs (330 kg)
Min. Bend Radius (Stationary / Installation)9.4 in (240 mm)
Nom. Conductor DCR5.86 Ohm/1000ft (19.2 Ohm/km)
Nominal Outer Diameter0.785 in (19.9 mm)
Nom Outer Shield DCR4.22 Ohm/1000ft (13.8 Ohm/km)
UL Temperature Operating90°C Dry, 90°C Wet -30C to 90C Dry, 75C wet
Voltage Rating600 V (TC-ER), 150 V (NPLF)