1062A Datasheet
The Belden 1062A is a UL-listed instrumentation cable featuring 50 pairs of 20 AWG and one 22 AWG bare copper conductors, PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for 300V (PLTC/CMG) and 150V (ITC) with an operating temperature range of -30 °C to +105 °C. This cable is designed for industrial control, digital instruments, DCS, PLC systems, and solenoid/valve actuator connections in harsh environments.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1062A Key Specifications
- Max. Current
- 3 Amps per conductor @ 25 °C
- Voltage Rating
- 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
- Operating Temperature
- -30 °C to +105 °C (UL Temperature 105 °C)
- Conductor Configuration
- 50 pairs of 20 AWG (7x28) bare copper + 1 comm wire of 22 AWG (7x30) bare copper
- Max. Pull Tension
- 1423 lbs (645.5 kg)
- Min. Bend Radius (Stationary / Installation)
- 11.4 in (290 mm)
- Nominal Outer Diameter
- 1.143 in (29.03 mm)
- Shielding
- Overall Beldfoil® (Bi-Laminate Alum+Poly) tape with 100% coverage and 20 AWG TC drainwire (no shield on comm wire)
Characteristics (datasheet)
- Voltage Rating
- 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
- Operating Temperature
- -30 °C to +105 °C (UL Temperature 105 °C)
- Conductor Configuration
- 50 pairs of 20 AWG (7x28) bare copper + 1 comm wire of 22 AWG (7x30) bare copper
- Max. Current
- 3 Amps per conductor @ 25 °C
- Nominal Outer Diameter
- 1.143 in (29.03 mm)
- Min. Bend Radius (Stationary / Installation)
- 11.4 in (290 mm)
- Max. Pull Tension
- 1423 lbs (645.5 kg)
- Shielding
- Overall Beldfoil® (Bi-Laminate Alum+Poly) tape with 100% coverage and 20 AWG TC drainwire (no shield on comm wire)
1062A Applications
- Industrial control
- Raceways, cable trays and ducts
- Digital control
- Instruments (4-20mA, 0-10V)
- Low voltage digital control (24V)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids, valves, actuators, positioners
Other Belden parts
- 70080 — The Belden 70080 is a discontinued 75 Ohm SDI coaxial cable of Mini RG-59 type,...
- 2003C — The Belden 2003C is a 2-conductor 18 AWG tinned copper electronic cable featurin...
- 5073C — The 5073C is a 3-conductor 16 AWG tinned copper cable with PVC insulation and a...
- 78384 — The part 78384 is a 4-pair 22 AWG tinned copper conductor ECOCABLE with modified...
- 78149 — The part 78149 is an ECOCABLE containing 9 pairs of 20 AWG stranded tinned coppe...
- 29529 — Belden part 29529 is a flexible motor supply cable built for Variable Frequency...
- 7997A — The Belden 7997A is a Category 5e outdoor plant (OSP) horizontal cable featuring...
- 1088A — The Belden 1088A is a 50-pair, 18 AWG bare copper instrumentation cable featurin...
More Bulk Wire Cable
- 5666 — The Belden 5666 is a 2-conductor, 26 AWG tinned copper cable with semi-rigid PVC...
- 79019 — The Belden 79019 is a 2-conductor 16 AWG tinned copper cable with modified polyp...
- 79247 — The part 79247 is a 6-conductor, 22 AWG tinned copper cable with modified polyph...
- 77218 — The Belden 77218 is a 9-conductor, 18 AWG tinned copper ECOCABLE with MPPE insul...
- 1118A — The Belden 1118A is a UL-listed instrumentation cable featuring a single pair of...
- 31520 — Part 31520 is a Belden low temp rubber lead wire with 20 AWG (10x30) stranded ti...
- 8743 — The Belden 8743 is an electronic multi-pair cable consisting of 6 pairs of 22 AW...
- 29503 — Belden 29503 is a flexible 600/1000 V motor supply cable built for variable freq...
1062A FAQ
What is 1062A?
1062A is a Bulk Wire Cable from Belden. The Belden 1062A is a UL-listed instrumentation cable featuring 50 pairs of 20 AWG and one 22 AWG bare copper conductors, PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for 300V (PLTC/CMG) and 150V (ITC) with an operating temperature range of -30 °C to +105 °C. This cable is designed for industrial control, digital instruments, DCS, PLC systems, and solenoid/valve actuator connections in harsh environments.
Who manufactures 1062A?
1062A is manufactured by Belden.
Where can I download the 1062A datasheet PDF?
The 1062A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1062A specifications
Click to ask a quick question:
Parameters
| Conductor Configuration | 50 pairs of 20 AWG (7x28) bare copper + 1 comm wire of 22 AWG (7x30) bare copper |
| Max. Current | 3 Amps per conductor @ 25 °C |
| Max. Pull Tension | 1423 lbs (645.5 kg) |
| Min. Bend Radius (Stationary / Installation) | 11.4 in (290 mm) |
| Nominal Outer Diameter | 1.143 in (29.03 mm) |
| Operating Temperature | -30 °C to +105 °C (UL Temperature 105 °C) |
| Shielding | Overall Beldfoil® (Bi-Laminate Alum+Poly) tape with 100% coverage and 20 AWG TC drainwire (no shield on comm wire) |
| Voltage Rating | 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC) |