The Belden 1050A is an 8-pair, 18 AWG bare copper instrumentation cable with PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, supporting an operating temperature range of -30°C to 90°C in dry and wet environments. This cable is designed for industrial control, low-voltage digital control, instrumentation, and process automation systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1050A Key Specifications
- Max Current
- 7 Amps per conductor @ 30°C
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature Rating
- 90°C Dry, 90°C Wet, -30°C to 90°C Dry/Wet
- Conductor
- 8 pairs, 18 AWG 7x26 bare copper (BC)
- Inner Shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, 20 AWG (7x28) TC drainwire per pair
- Max. Pull Tension
- 393 lbs (178 kg)
- Nom. Conductor DCR
- 6.66 Ohm/1000ft
- Outer Jacket
- Black PVC, 0.063 in (1.6 mm) thickness, nominal diameter 0.675 in (17.1 mm)
Characteristics (datasheet)
- Conductor
- 8 pairs, 18 AWG 7x26 bare copper (BC)
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Temperature Rating
- 90°C Dry, 90°C Wet, -30°C to 90°C Dry/Wet
- Inner Shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, 20 AWG (7x28) TC drainwire per pair
- Outer Shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, 18 AWG (7x26) TC drainwire
- Outer Jacket
- Black PVC, 0.063 in (1.6 mm) thickness, nominal diameter 0.675 in (17.1 mm)
- Max Current
- 7 Amps per conductor @ 30°C
- Nom. Conductor DCR
- 6.66 Ohm/1000ft
- Max. Pull Tension
- 393 lbs (178 kg)
1050A Applications
- Industrial control
- Raceways, cable trays and ducts
- Digital control
- Instruments (4-20mA, 0-10V)
- Low voltage digital control (24V)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids
- Valves
- Actuators
- Positioners
Other Belden parts
- 9572 — The Belden 9572 is a 2-conductor 16 AWG solid bare copper electronic cable featu...
- 25462 — Belden 25462 is a 2-conductor, 20 AWG (7x28) stranded tinned copper cable with P...
- 45292 — Belden 45292 is an XTRAGUARD 4 cable with 2 pairs of 20 AWG (7/28) stranded tinn...
- 83659 — The Belden 83659 is a high-temperature multi-conductor cable featuring nine 18 A...
- 28156A — The Belden 28156A is a UL Type TC power and control cable with three 4 AWG bare...
- 975694702 — 10A 1kV Gold-Plated Brass Plug Connector
- 7791A — The Belden 7791A is a VideoFLEX sub-miniature digital coax snake cable with 10 2...
- 7435W — The Belden 7435W is a highly flexible (MachFlex) industrial cable featuring two...
More Bulk Wire Cable
- 8076 — The Belden 8076 is a single-conductor magnet wire constructed from solid bare co...
- 6546PA — The Belden 6546PA is a plenum-rated cable designed for security, pro audio, and...
- 5857 — The Belden 5857 is a single-conductor 18 AWG silver-plated copper hook-up wire w...
- 6500FC — The Belden 6500FC is a plenum-rated security, pro audio, and intercom cable feat...
- 2003C — The Belden 2003C is a 2-conductor 18 AWG tinned copper electronic cable featurin...
- 1224 — The Belden 1224 is a CAT5e+ (350 MHz) premise horizontal cable featuring four pa...
- 83334E — The Belden 83334E is a high-temperature electronic cable featuring three 22 AWG...
- 1040A — The Belden 1040A is a UL-listed instrumentation cable consisting of 6 pairs of 1...
1050A FAQ
What is 1050A?
1050A is a Bulk Wire Cable from Belden. The Belden 1050A is an 8-pair, 18 AWG bare copper instrumentation cable with PVC-nylon insulation, individual and overall Beldfoil shielding, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF, supporting an operating temperature range of -30°C to 90°C in dry and wet environments. This cable is designed for industrial control, low-voltage digital control, instrumentation, and process automation systems.
Who manufactures 1050A?
1050A is manufactured by Belden.
Where can I download the 1050A datasheet PDF?
The 1050A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1050A specifications
Click to ask a quick question:
Parameters
| Conductor | 8 pairs, 18 AWG 7x26 bare copper (BC) |
| Inner Shield | Bi-Laminate (Alum+Poly) tape, 100% coverage, 20 AWG (7x28) TC drainwire per pair |
| Max Current | 7 Amps per conductor @ 30°C |
| Max. Pull Tension | 393 lbs (178 kg) |
| Nom. Conductor DCR | 6.66 Ohm/1000ft |
| Outer Jacket | Black PVC, 0.063 in (1.6 mm) thickness, nominal diameter 0.675 in (17.1 mm) |
| Outer Shield | Bi-Laminate (Alum+Poly) tape, 100% coverage, 18 AWG (7x26) TC drainwire |
| Temperature Rating | 90°C Dry, 90°C Wet, -30°C to 90°C Dry/Wet |
| Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |