1046A Datasheet
The Belden 1046A is a 36-pair UL-listed instrumentation cable featuring 16 AWG (7x24) bare copper conductors with PVC-nylon insulation (ICEA Chart E1 color code), individual and overall Beldfoil shields, and a black PVC outer jacket. It supports 600V TC-ER and 150V NPLF voltage ratings with operating temperatures of 90°C dry and 75°C wet. This cable is designed for industrial control, digital control, instrumentation, solenoids, valves, and PLC systems in raceways, ducts, or direct burial applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1046A Key Specifications
- Max. Current
- 6 Amps per conductor @ 30°C
- UL Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Operating Temperature
- -30°C to 90°C Dry,90° wet (UL Temperature: 90°C Dry, 75°C Wet)
- Bend Radius (Stationary Min. / Installation Min.)
- 17.4 in (442 mm)
- Bulk Cable Weight
- 1.274 lbs/1000ft
- Conductor size
- 16 AWG 7x24 BC - Bare Copper
- Max. Pull Tension
- 2629 lbs (1192 kg)
- Nom. Conductor DCR
- 4.2 Ohm/1000ft
Characteristics (datasheet)
- Conductor size
- 16 AWG 7x24 BC - Bare Copper
- Number of pairs
- 36
- UL Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Max. Current
- 6 Amps per conductor @ 30°C
- Nom. Conductor DCR
- 4.2 Ohm/1000ft
- Nom. Inner Shield DCR
- 5.49 Ohm/1000ft (18.0 Ohm/km)
- Nom Outer Shield DCR
- 2.84 Ohm/1000ft (9.32 Ohm/km)
- Operating Temperature
- -30°C to 90°C Dry,90° wet (UL Temperature: 90°C Dry, 75°C Wet)
- Overall Cable Diameter (Nominal)
- 1.471 in (37.36 mm)
- Bulk Cable Weight
- 1.274 lbs/1000ft
- Max. Pull Tension
- 2629 lbs (1192 kg)
- Bend Radius (Stationary Min. / Installation Min.)
- 17.4 in (442 mm)
1046A Applications
- Industrial Control
- Raceways Cable trays and ducts
- Digital Control
- Instruments (4-20ma, 0-10v, ...)
- low voltage digital control (24v, …)
- encoders
- control circuits
- distributed control system (DCS)
- programmable logic controller (PLC)
- Solenoids
- Valves
- Actuators
- Positioners
Other Belden parts
- 9341 — The Belden 9341 is a high-performance instrumentation cable featuring a single p...
- 24512D — The Belden 24512D is a Canadian instrumentation cable (TC-ACIC) rated 600 V, con...
- 1320C — The Belden 1320C is a multi-conductor communication and control cable consisting...
- 8467 — The Belden 8467 is a 7-conductor electronic cable made of 18 AWG (19x30) tinned...
- 5224C — The Belden 5224C is an XTRAGUARD 1 multi-conductor cable featuring 19 conductors...
- 77222 — The Belden 77222 is an ECOCABLE featuring two 16 AWG tinned copper conductors wi...
- 5073C — The 5073C is a 3-conductor 16 AWG tinned copper cable with PVC insulation and a...
- 29501 — Belden 29501 is a 600/1000 V flexible motor supply cable built for variable freq...
More Bulk Wire Cable
- 77214 — The Belden 77214 is an indoor, 3-conductor, 18 AWG tinned copper cable with mPPE...
- 28628A — Belden 28628A is a 50-conductor, 16 AWG (7x24 bare copper) UL Type TC power and...
- 83712 — The Belden 83712 is a high-temperature 12-conductor 16 AWG tinned copper cable w...
- 7852A — The Belden 7852A is a discontinued Category 6+ Enhanced Premise Horizontal Cable...
- 83337E — The Belden 83337E is a high-temperature, 3-conductor 16 AWG silver-plated copper...
- 8846MN — The Belden 8846MN is a SpaceMaker™ 7-conductor 16AWG tinned copper cable with po...
- 9899 — The Belden 9899 is a low-temp plastic lead wire featuring an 18 AWG (65x36) tinn...
- 5154C — The Belden 5154C is a shielded, 4-conductor 20 AWG tinned copper cable with PVC...
1046A FAQ
What is 1046A?
1046A is a Bulk Wire Cable from Belden. The Belden 1046A is a 36-pair UL-listed instrumentation cable featuring 16 AWG (7x24) bare copper conductors with PVC-nylon insulation (ICEA Chart E1 color code), individual and overall Beldfoil shields, and a black PVC outer jacket. It supports 600V TC-ER and 150V NPLF voltage ratings with operating temperatures of 90°C dry and 75°C wet. This cable is designed for industrial control, digital control, instrumentation, solenoids, valves, and PLC systems in raceways, ducts, or direct burial applications.
Who manufactures 1046A?
1046A is manufactured by Belden.
Where can I download the 1046A datasheet PDF?
The 1046A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1046A specifications
Click to ask a quick question:
Parameters
| Bend Radius (Stationary Min. / Installation Min.) | 17.4 in (442 mm) |
| Bulk Cable Weight | 1.274 lbs/1000ft |
| Conductor size | 16 AWG 7x24 BC - Bare Copper |
| Max. Current | 6 Amps per conductor @ 30°C |
| Max. Pull Tension | 2629 lbs (1192 kg) |
| Nom. Conductor DCR | 4.2 Ohm/1000ft |
| Nom. Inner Shield DCR | 5.49 Ohm/1000ft (18.0 Ohm/km) |
| Nom Outer Shield DCR | 2.84 Ohm/1000ft (9.32 Ohm/km) |
| Number of pairs | 36 |
| Operating Temperature | -30°C to 90°C Dry,90° wet (UL Temperature: 90°C Dry, 75°C Wet) |
| Overall Cable Diameter (Nominal) | 1.471 in (37.36 mm) |
| UL Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |