1056A Datasheet

BeldenBulk Wire Cable

The Belden 1056A is a UL-listed instrumentation and control cable featuring 4 pairs of 20 AWG and one 22 AWG bare copper conductors with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is designed for use in industrial control systems, DCS, PLCs, solenoids, valves, actuators, and low-voltage digital control circuits. The cable is rated for 300 V (PLTC/CMG) / 150 V (ITC) and operates reliably within a temperature range of -30°C to +105°C.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

1056A Key Specifications

Max. Current
5.6 Amps per conductor (pairs) @ 30°C, 9.6 Amps per conductor (comm wire) @ 30°C
Voltage Rating
300 V (PLTC, CMG, AWM 2464), 150 V (ITC)
Operating Temperature
-30°C to +105°C (UL temperature 105°C)
Conductor structure
4 pairs of 20 AWG (7x28) bare copper + 1 comm wire of 22 AWG (7x30) bare copper
Min. Bend Radius
4.9 in (120 mm) stationary / installation
Nom. Conductor DCR
10.9 Ohm/1000ft (pairs), 17.2 Ohm/1000ft (comm wire)
Outer Jacket
Black PVC, nominal thickness 0.042 in (1.1 mm), nominal diameter 0.405 in (10.3 mm)
Outer Shield
Bi-Laminate (Alum+Poly) tape, 100% coverage, with 20 AWG (7x28) TC drainwire

Characteristics (datasheet)

Conductor structure
4 pairs of 20 AWG (7x28) bare copper + 1 comm wire of 22 AWG (7x30) bare copper
Outer Shield
Bi-Laminate (Alum+Poly) tape, 100% coverage, with 20 AWG (7x28) TC drainwire
Outer Jacket
Black PVC, nominal thickness 0.042 in (1.1 mm), nominal diameter 0.405 in (10.3 mm)
Voltage Rating
300 V (PLTC, CMG, AWM 2464), 150 V (ITC)
Operating Temperature
-30°C to +105°C (UL temperature 105°C)
Max. Current
5.6 Amps per conductor (pairs) @ 30°C, 9.6 Amps per conductor (comm wire) @ 30°C
Nom. Conductor DCR
10.9 Ohm/1000ft (pairs), 17.2 Ohm/1000ft (comm wire)
Min. Bend Radius
4.9 in (120 mm) stationary / installation

1056A Applications

  • Industrial Control
  • Raceways, cable trays and ducts
  • Digital Control
  • Instruments (4-20ma, 0-10v)
  • Low voltage digital control (24v)
  • Encoders
  • Control circuits
  • Distributed control system (DCS)
  • Programmable logic controller (PLC)
  • Solenoids
  • Valves
  • Actuators
  • Positioners

Other Belden parts

  • 79009FF — The Belden 79009FF is a Safe-T-Line fire-resistant multi-conductor cable featuri...
  • 88641 — The Belden 88641 is a high-temperature, shielded two-conductor electronic cable...
  • 5936 — The Belden 5936 is a 7-conductor, 28 AWG tinned copper cable with semi-rigid PVC...
  • 7770ELY — The Belden 7770ELY is a Category 7A enhanced premise horizontal cable (1600 MHz)...
  • 70059 — The Belden 70059 is an 8-pair digital audio cable constructed with 24 AWG oxygen...
  • 1712 — The Belden 1712 is a 2-conductor 20 AWG tinned copper communication and control...
  • 31014 — The Belden 31014 is a 14 AWG stranded tinned copper lead wire with XLPO/XLP/XLPE...
  • 4443FDW — The Belden 4443FDW is an OSDP RS-485 transmission cable designed for use in inst...

More Bulk Wire Cable

  • 1743C — The Belden 1743C is a 4-conductor, 20 AWG tinned copper shielded communication a...
  • 79219 — The Belden 79219 is a 3-conductor, 16 AWG tinned copper cable with mPPE insulati...
  • 78346 — The Belden 78346 is a high-flexibility, shielded 6-conductor cable built with 20...
  • 7922A — The Belden 7922A is a DataTuff® Cat 5e industrial Ethernet cable featuring four...
  • 21652 — Belden 21652 is a 600 V Type TC/CIC power and control cable with four 8 AWG stra...
  • 32414 — Belden part 32414 is a 14 AWG stranded tinned copper lead wire with silicone rub...
  • 9967 — The Belden 9967 is a 3-conductor, 22 AWG tinned copper cable with PVC-nylon insu...
  • 7450WS — The Belden 7450WS is a high-flexibility MachFlex™ cable designed for continuous...

1056A FAQ

What is 1056A?

1056A is a Bulk Wire Cable from Belden. The Belden 1056A is a UL-listed instrumentation and control cable featuring 4 pairs of 20 AWG and one 22 AWG bare copper conductors with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is designed for use in industrial control systems, DCS, PLCs, solenoids, valves, actuators, and low-voltage digital control circuits. The cable is rated for 300 V (PLTC/CMG) / 150 V (ITC) and operates reliably within a temperature range of -30°C to +105°C.

Who manufactures 1056A?

1056A is manufactured by Belden.

Where can I download the 1056A datasheet PDF?

The 1056A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 1056A specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor structure4 pairs of 20 AWG (7x28) bare copper + 1 comm wire of 22 AWG (7x30) bare copper
Max. Current5.6 Amps per conductor (pairs) @ 30°C, 9.6 Amps per conductor (comm wire) @ 30°C
Min. Bend Radius4.9 in (120 mm) stationary / installation
Nom. Conductor DCR10.9 Ohm/1000ft (pairs), 17.2 Ohm/1000ft (comm wire)
Operating Temperature-30°C to +105°C (UL temperature 105°C)
Outer JacketBlack PVC, nominal thickness 0.042 in (1.1 mm), nominal diameter 0.405 in (10.3 mm)
Outer ShieldBi-Laminate (Alum+Poly) tape, 100% coverage, with 20 AWG (7x28) TC drainwire
Voltage Rating300 V (PLTC, CMG, AWM 2464), 150 V (ITC)