Wire Cable Assemblies

28132A

The Belden 28132A is a 25-conductor power and control cable built with 12 AWG (7x20) bare copper conductors, PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF) at 90°C dry/wet and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.

Belden
14 3

28149AS

The Belden 28149AS is a UL Type TC (1277) tray cable with two 8 AWG bare copper conductors and one 10 AWG bare copper ground conductor (Class B stranding), PVC/nylon insulation, an overall Beldfoil® shield, and a black PVC jacket rated 600 V. It is UL rated 90°C dry / 75°C wet, operates from -25°C to +90°C, and is TC-ER listed with sunlight resistance and direct burial suitability. It is intended for harsh-environment digital and serial two-way communication, oil and gas extraction/refining, petrochemical, Profibus and Foundation FieldBus process automation, and remote long-distance applications.

Belden
14 3

28153A

Belden part 28153A is a UL Type TC power and control cable with three bare copper 6 AWG conductors (7x14 stranding) plus one bare copper 8 AWG ground conductor (7x16 stranding), PVC-nylon insulation, and a black PVC jacket rated 600 V. It is suitable for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations, and is rated 90 °C dry/wet with sunlight resistance and direct burial suitability.

Belden
14 3

28160A

The Belden 28160A is a UL Type TC power and control cable consisting of four 2 AWG bare copper conductors plus one 6 AWG bare copper ground conductor. It has PVC/nylon insulation and a black PVC outer jacket, is rated 600 V and 90 °C dry/wet, and is suitable for indoor, outdoor, sunlight-resistant, and direct burial use including Class 1 Division 2 hazardous locations. A 5,000 ft reel put-up (item 28160A 0105000) is available with a ripcord in the jacket.

Belden
14 3

28161A

The Belden 28161A is a UL Type TC power and control cable with three 1 AWG bare copper conductors plus one 6 AWG bare copper ground wire, PVC-nylon insulation, and a black PVC jacket rated 600 V. It is rated 90 °C dry and wet, is sunlight resistant and suitable for direct burial, and is intended for power and control applications up to 600 V including Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 1.125 in (28.58 mm), a maximum pull tension of 3408.3 lbs (1546.0 kg), and a bulk weight of 1177 lbs/1000 ft.

Belden
14 3

28178A

The Belden 28178A is a UL Type TC power and control cable with four 4/0 AWG bare copper conductors plus one 4 AWG bare copper ground conductor. It features PVC/nylon insulation, a black PVC outer jacket with ripcord, and is rated 600 V, 90 °C dry/wet, with sunlight resistance and suitability for direct burial and Class 1 Division 2 hazardous locations.

Belden
14 3

28326A

The Belden 28326A is a 4-conductor, 18 AWG (7x26 stranded bare copper) power and control cable with PVC/nylon conductor insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with a 90 °C dry/wet rating and an operating range of -30 °C to 90 °C. It is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, and is sunlight resistant and suitable for direct burial.\n\n

Belden
14 3

28609A

The Belden 28609A is a UL Type TC (1277) power and control cable containing 19 conductors of 18 AWG bare copper (7x26 stranding) with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), operates wet/dry from -30°C to 90°C, and is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.

Belden
14 3

29004

Belden 29004 is a 600 V ACIC power and control cable containing three 16 AWG stranded bare copper conductors plus a 16 AWG bare copper ground wire. It uses XLPE insulation, a PVC inner jacket, aluminum interlocked armor, and a PVC outer jacket, and is rated for indoor, outdoor, sunlight-resistant, and buried installations.

Belden
14 3

29006

Belden 29006 is a 600 V ACIC power and control cable with twelve 16 AWG stranded bare copper conductors plus a bare copper ground wire. It uses cross-linked polyethylene insulation, a PVC inner jacket, aluminum interlocked armor, and a PVC outer jacket, and is suitable for indoor, outdoor, sunlight-resistant, and burial installations up to 600 V.

Belden
14 3

29504

Belden 29504 is a flexible VFD motor supply cable with three 8 AWG tinned copper conductors, XLPE insulation, and an overall Beldfoil plus tinned copper braid shield. It includes an insulated 8 AWG ground and four segmented 14 AWG tinned copper ground/drain wires under a black PVC jacket. Rated 600/1000 V TC-ER and 1000 V WTTC at 90°C dry/wet, it is intended for Variable Frequency Drives (VFD) and AC motor and drive systems.\n\n

Belden
14 3

29506

Belden 29506 is a flexible 600/1000 V motor supply cable designed for Variable Frequency Drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations. It contains three 4 AWG tinned copper conductors with XLPE insulation, an insulated 4 AWG ground, four uninsulated 10 AWG tinned copper ground/drain wires, an overall shielded construction, and a black PVC jacket rated 90 °C dry/wet. The cable complies with TC-ER, WTTC, UL flexible motor supply cable, AWM, CIC/TC, and RoHS/CE requirements.

Belden
14 3

29557C

The Belden 29557C is a CSA-rated VFD power cable containing three 1 AWG bare copper conductors and three 10 AWG segmented bare copper grounds. It uses XLPE insulation, dual helically applied bare copper tape shields, and a black PVC jacket with a ripcord, rated for 1000 V. It is intended for variable frequency drives, AC motor and drive systems, and Canadian applications.

Belden
14 3

29558C

Belden 29558C is a 3-conductor VFD power cable with 1/0 AWG bare copper conductors, XLPE insulation, and three 10 AWG segmented bare copper grounds, plus dual 100% coverage helical copper tape shielding and a black PVC jacket. It is rated 1000 V (CSA TC) and intended for variable frequency drives, AC motor and drive systems, and Canadian applications. The cable is suitable for indoor, outdoor, sunlight-resistant, oil-resistant, and direct burial use.

Belden
14 3

29724C

Belden 29724C is a 3-conductor VFD power cable with 8 AWG bare copper XLPE-insulated conductors and a 10 AWG symmetrical segmented ground (3 of 14 AWG), shielded with dual helical bare copper tapes and jacketed in black PVC. It is rated 2000 V (TC) / 1000 V (CSA AWM) at 90 °C dry and wet, and is intended for variable frequency drives, AC motor and drive systems, and high voltage requirements. The cable is suitable for indoor, outdoor, sunlight-resistant, oil-resistant, and direct burial installations.

Belden
14 3

30808

Belden 30808 is an 8 AWG (54x25) stranded tinned copper lead wire with silicone rubber insulation and a lacquered fiberglass braid outer jacket. It is rated 600 V RMS and operates from -70 °C to +200 °C, complying with AWM 3125 and CSA SEW-2. It is intended for Class 130(B), 155(F) or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and other high temperature applications.

Belden
14 3

30812

The Belden 30812 is a 12 AWG stranded tinned copper lead wire with silicone rubber insulation and a lacquered glass braid outer jacket. It is rated for 600 V RMS and 150 °C, and is intended for Class 130(B), 155(F), or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and high temperature applications.

Belden
14 3

31014

The Belden 31014 is a 14 AWG stranded tinned copper lead wire with XLPO/XLP/XLPE thermoset insulation, rated 600 V RMS and 90 °C, with a VW-1 flammability rating. It has an overall diameter of 0.144 in (3.66 mm) and a bulk weight of 20 lbs/1000ft (30 kg/km). It is intended for wiring switchboards, panelboards, and distribution boards.

Belden
14 3

32410

Belden 32410 is a 10 AWG stranded tinned copper lead wire with silicone rubber insulation and a lacquered glass braid outer jacket, rated AWM 3075 and CSA SEW-2 at 600 V and 200 °C. It is designed for Class 130(B), 155(F) or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and other high temperature applications.

Belden
14 3

33390

Belden 33390 is a lead wire with a 1/0 AWG (262x24) tinned copper conductor and silicone rubber insulation, rated AWM 3214 / CSA Type AWM 600 V RMS at 150°C. It is intended for Class 155(F) or Class 180(H) motor lead systems, high temperature applications, and internal wiring of lighting fixtures and appliances.

Belden
14 3