Wire Cable Assemblies
24504D
The Belden 24504D is a Canadian TC-ACIC instrumentation and control cable rated 600 V, built with 12 pairs of 16 AWG (7x24) stranded tinned copper conductors with XLPE insulation. It has individual and overall Beldfoil shields, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket, rated for -40 °C to 90 °C wet / 105 °C dry service. It is intended for industrial control, raceways, cable trays, digital control, instruments, encoders, DCS/PLC systems, solenoids, valves, actuators, and positioners.
24508D
Belden 24508D is a Canadian Instrumentation Cable (TC-ACIC) rated 600 V, constructed with four 16 AWG (7x24) tinned copper triads, XLPE insulation, individual and overall Beldfoil® shields, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket. It is rated for -40 °C to +90 °C wet / 105 °C dry and is suited for industrial control, raceways, cable trays and ducts, digital control, instruments, encoders, control circuits, DCS, PLCs, solenoids, valves, actuators, and positioners.
25016
Belden part 25016 is an XTRAGUARD 2 cable with six 24 AWG (7x32) stranded tinned copper conductors, semi-rigid PVC insulation, and a slate polyurethane outer jacket. It is rated 300 V under AWM/Style 20668 and CSA AWM, with an operating temperature range of -30 °C to +90 °C. It is intended for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25064
Belden part 25064 is an XTRAGUARD 2 cable with 4 conductors of 18 AWG stranded tinned copper, PVC insulation, and a slate polyurethane outer jacket. It is rated 300 V and intended for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25113
Belden part 25113 is an XTRAGUARD 2 cable with three 24 AWG (7/32) tinned copper conductors, semi-rigid PVC insulation, an aluminum/polyester plus tinned copper braid shield, and a slate polyurethane outer jacket. It is rated 300 V and is used for data, communication, audio, and low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25162
Belden 25162 is an XTRAGUARD 2 two-conductor cable with 18 AWG (16x30) tinned copper conductors, PVC insulation, an overall aluminum/polyester shield plus a tinned copper drainwire and 70% tinned copper braid, and a slate polyurethane outer jacket. It is rated 300 V (AWM 20668 / CSA AWM) and is intended for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable has a nominal overall diameter of 0.254 in (6.45 mm) and a stationary minimum bend radius of 2.5 in (64 mm).
25163
Belden 25163 is a 3-conductor 18 AWG (16x30 stranded tinned copper) cable with PVC insulation, an overall aluminum/polyester plus tinned-copper braid shield, and a slate polyurethane outer jacket. It is rated 300 V (AWM 20668 / CSA AWM) with a UL temperature rating of 105 °C and an operating range of -30 °C to +90 °C. It is intended for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.{
25164
Belden 25164 is an XTRAGUARD 2 cable with 4 conductors of 18 AWG (16x30) tinned copper, PVC insulation, an overall aluminum/polyester shield, and a slate polyurethane outer jacket. It is rated 300 V and is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25373
Belden 25373 is an XTRAGUARD 2 cable with 3 shielded pairs of 18 AWG (16x30) tinned copper conductors, PVC insulation, an overall aluminum/polyester bi-laminate shield with 100% coverage and an 18 AWG drainwire, and a slate polyurethane outer jacket with ripcord. It is rated for 300 V (AWM 20668 / CSA AWM), operates from -30°C to +90°C (UL 105°C), and is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25382
Belden part 25382 is XTRAGUARD 2, a 2-conductor 18 AWG (16/30) tinned copper cable with PVC insulation, an overall aluminum/polyester shield (100% coverage) with drainwire, and a slate polyurethane (TPU) outer jacket. It is rated 300 V under UL AWM/STYLE 20668 (90 °C) and AWM/STYLE 1569 (105 °C), with CSA AWM I/II A/B and FT1/VW-1 flammability ratings. It is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25388
Belden part 25388 is an XTRAGUARD 2 cable with 8 conductors of 18 AWG (16/30) tinned copper, PVC insulation, and an overall aluminum/polyester shield with a drain wire. It has a slate polyurethane (TPU) outer jacket with a ripcord and is rated 300 V. It is intended for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25463
Belden part 25463 is an XTRAGUARD 2 three-conductor 20 AWG (7/28) tinned-copper cable with PVC insulation, an overall aluminum/polyester foil shield (100% coverage) with a 20 AWG tinned-copper drainwire, and a slate polyurethane outer jacket with ripcord. It is rated 300 V (UL AWM 20668) / 600 V (CSA AWM, TEW), 105°C UL with -30°C to +90°C operating range, and is intended for data, communication, audio, and low-level signal transmission such as industrial networking, serial communication, control panels, automation equipment, and instrumentation.
25503D
The Belden 25503D is a Canadian instrumentation cable (TC-ACIC) rated 600 V, containing four pairs of 18 AWG (7x26) tinned copper conductors with XLPE insulation, individual and overall Beldfoil shielding, a PVC inner jacket, steel interlock armor, and a black PVC outer jacket. It is intended for industrial control, raceways, cable trays and ducts, digital control, instrument signals (4-20 mA, 0-10 V), low voltage digital control (24 V), encoders, control circuits, DCS/PLC systems, solenoids, valves, actuators, and positioners.
25508D
The Belden 25508D is a Canadian Instrumentation Cable (TC-ACIC) rated 600 V, containing 8 triads of 16 AWG (7x24) tinned copper conductors with XLPE insulation. It has an overall Beldfoil shield, PVC inner jacket, steel interlock armor, and a black PVC outer jacket, rated for -40 °C to 105 °C dry / 90 °C wet. It is intended for industrial control, raceways, cable trays, digital control, instruments, DCS, PLC, solenoids, valves, actuators, and positioners.
27087A
Belden 27087A is a 9-conductor 14 AWG (7x22) bare copper control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V RMS (Type TC) and 150 V RMS (NPLF) and is intended for industrial control, raceways, cable trays and ducts, digital control instruments, encoders, solenoids, valves, actuators, and positioners.
27153A
Belden 27153A is a UL Type TC (1277) power and control cable with three 6 AWG bare copper conductors plus one 8 AWG bare copper ground wire, PVC/nylon insulation, and a black PVC jacket. It is rated 600 V, 90 °C wet/dry, sunlight resistant and suitable for direct burial, and is recommended for power and control applications up to 600 V including Class 1 Division 2 hazardous locations.
27636A
Belden 27636A is a UL Type TC (1277) power and control cable with two 14 AWG (7x22) bare copper conductors, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC) / 150 V (NPLF), 90 °C wet/dry, and is suitable for indoor, outdoor, sunlight-resistant, and direct burial use, including Class 1 Division 2 hazardous locations.
27917A
The Belden 27917A is a 2-conductor, 16 AWG (7x24 stranded bare copper) Type TC power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC) / 150 V (NPLF), 90 °C wet/dry, and is listed as suitable for indoor, outdoor, sunlight-resistant, and direct-burial power and control applications up to 600 V.
28085A
The Belden 28085A is a UL Type TC (1277) power and control cable with seven 14 AWG (7x22) bare copper conductors, PVC/nylon insulation (E2 color code), and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with UL temperature of 90 °C dry / 90 °C wet and an operating range of -30 °C to 90 °C wet/dry. It is suitable for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
28090A
The Belden 28090A is a UL Type TC (1277) power and control cable with 12 conductors of 14 AWG (7x22) bare copper, PVC/nylon insulation with E2 color code, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry/wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations. Recommended applications include power and control circuits up to 600 V.