Wire Cable Assemblies

50012L

The Belden 50012L is an RS-485 cable comprising 2 pairs of 24 AWG stranded tinned copper conductors with foamed electron-beam cross-linked polyethylene insulation, an overall foil plus tinned copper braid shield, and a low smoke zero halogen flame-retardant jacket. It is ABS approved and intended for RS 232/422/485, CANBUS, and MODBUS communication in machine control, SCADA, temperature control, building automation, offshore, oil & gas, and railway applications.

Belden
14 5

24516D

Belden 24516D is a Canadian Instrumentation Cable (TC-ACIC) rated 600 V RMS, with one triad of 18 AWG (7x26) tinned copper conductors, XLPE insulation, overall Beldfoil shield, PVC inner jacket, aluminum interlock armor, and black PVC outer jacket. It is rated for 105°C dry and 90°C wet operation from -40°C to +105°C and is used for industrial control, DCS, PLC, instruments, solenoids, valves, actuators, and positioners.

Belden
14 4

25506D

Belden 25506D is a Canadian TC-ACIC 600 V instrumentation cable built with one 18 AWG (7x26) tinned copper pair, XLPE insulation, an overall Beldfoil shield, a PVC inner jacket, steel interlock armor, and a black PVC outer jacket. It is rated -40 °C to +90 °C wet / 105 °C dry and is suited for industrial control, raceways, cable trays and ducts, digital control, instruments such as 4-20 mA and 0-10 V, encoders, control circuits, DCS/PLC systems, solenoids, valves, actuators, and positioners.

Belden
14 4

27916A

The Belden 27916A is a 2-conductor 18 AWG (7x26 bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC) / 150 V (NPLF) at 90 °C wet/dry and is intended for power and control applications up to 600 V, including indoor, outdoor, sunlight-resistant, and direct burial use.

Belden
14 4

28082A

The Belden 28082A is a UL Type TC (1277) power and control cable with four 14 AWG (7x22) bare copper conductors, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations.

Belden
14 4

28087A

The Belden 28087A is a 9-conductor, 14 AWG (7x22) bare copper power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with a nominal overall diameter of 0.499 in (12.7 mm).

Belden
14 4

28103A

The Belden 28103A is a 25-conductor, 14 AWG (7x22) bare copper tray cable with PVC/nylon (E2) insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations. The cable has no overall shield, includes a ripcord, and is rated for indoor/outdoor, sunlight-resistant, UV-resistant, and direct-burial use.

Belden
14 4

28148A

The 28148A is a Belden UL Type TC power and control cable with 12 conductors of 10 AWG bare copper (7x18 stranding), PVC-nylon insulation, and a black PVC jacket rated 600 V. It is intended for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with 90 °C dry/wet ratings and sunlight resistance for direct burial.

Belden
14 4

28175A

The Belden 28175A is a UL Type TC power and control cable with four 3/0 AWG bare copper conductors and one uninsulated 4 AWG bare copper ground conductor. It features PVC/nylon insulation, a black PVC jacket with ripcord, and is rated 600 V, 90 °C dry/wet, suitable for indoor, outdoor, sunlight-resistant, direct-burial, and Class 1 Division 2 hazardous locations.

Belden
14 4

28338A

Belden 28338A is a UL Type TC (1277) power/control cable with four 16 AWG (7x24) bare copper conductors, PVC-nylon E2 insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), 90 °C dry/wet, sunlight resistant and suitable for direct burial, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations. No pinout or absolute maximum ratings apply because this is a bulk cable rather than a pin-based electronic component. It carries no separate top-side marking code in the datasheet. The stated applications are power and control applications up to 600 V and Class 1 Division 2 hazardous locations. Key specs include 4 x 16 AWG (7x24) bare copper conductors, PVC/nylon insulation at 0.020 in (0.51 mm), PVC jacket at 0.047 in (1.2 mm) with 0.331 in (8.41 mm) nominal diameter, 4.2 Ohm/1000ft nominal conductor DCR, 14.4 A max current per conductor at 30 °C, 140 lbs (64 kg) max pull tension, and 71 lbs/1000ft bulk weight. There is no Absolute Maximum Ratings table or pin-by-pin table in this document.

Belden
14 4

28605A

The Belden 28605A is a UL Type TC (1277) power and control cable with 15 bare copper conductors sized 18 AWG (7x26 stranding), PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90°C dry/wet temperature rating, and is suitable for indoor, outdoor, sunlight-resistant, and direct-buried installations, including Class 1 Division 2 hazardous locations.

Belden
14 4

28613A

Belden 28613A is a 37-conductor 18 AWG (7x26) bare copper power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90°C dry and wet temperature ratings, and is suited for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.728 in (18.5 mm) and a maximum pull tension of 828.8 lbs (375.9 kg).

Belden
14 4

28644A

The Belden 28644A is a 60-conductor, 14 AWG (Class B) bare copper Type TC cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V RMS (TC-ER) with a 90 °C dry/wet temperature rating and is designed for harsh environments such as oil and gas extraction/refining, petrochemical sites, and Profibus or Foundation FieldBus process automation.

Belden
14 4

50013L

Belden 50013L is an RS-485 cable with three pairs (six elements) of 24 AWG stranded tinned copper conductors, electron-beam cross-linked foam polyethylene insulation, an overall foil (bi-laminate aluminum/polyester) plus tinned copper braid shield, and a low smoke zero halogen jacket. It is ABS approved, flame retardant per IEC 60332-3-22 Category A, and rated 300 V with an operating temperature of -40°C To +90°C. The cable is designed for RS-232/422/485, CANbus, and Modbus communication networks in machine control, temperature controllers, control panels, SCADA systems, and emergency evacuation/shutdown systems for building automation, offshore, oil & gas, and railway applications.

Belden
14 4

50014L

The Belden 50014L is an RS-485 cable built with 4 pairs of 24 AWG stranded tinned copper conductors, electron-beam cross-linked foam polyethylene insulation, an overall foil plus tinned copper braid shield, and a low smoke zero halogen jacket. It is designed for RS 232/422/485, CANBUS, and MODBUS communication protocols in applications such as machine control networks, SCADA, temperature controllers, and emergency evacuation/shutdown systems in building automation, offshore, oil & gas, and railway installations. The cable is ABS approved, flame retardant per IEC 60332-3-22 Category A, and rated for 300 V operation from -40°C to +90°C.

Belden
14 4

21638

The Belden 21638 is a 40-conductor CSA Tray TC-CIC cable rated 600 V with 10 AWG (7x18) bare copper conductors, XLPE insulation, and a black PVC outer jacket, plus one 12 AWG bare copper ground wire. It is rated 90 °C dry/wet and is suitable for CEC power and control applications in indoor, outdoor, and direct burial locations.

Belden
14 3

21657

Belden 21657 is a 600 V Type TC/CIC power and control cable with three 8 AWG stranded (7x12) bare copper conductors plus a bare copper ground wire. It features flame-retardant cross-linked polyethylene insulation and a flame-retardant PVC jacket, rated for wet/dry operation from -40 °C to 90 °C. It is suitable for CEC power and control applications.

Belden
14 3

21672

The Belden 21672 is a CSA Type TC-CIC 600 V tray cable with three 2/0 AWG bare copper conductors and one 6 AWG bare copper ground conductor. It has XLPE/XLPE-type insulation, a black PVC outer jacket with ripcord, and is rated 90 °C dry/wet for indoor/outdoor direct burial use in CEC power and control applications. It complies with TC/CIC standards, FT4 flammability, and RoHS/WEEE/China RoHS II directives.{

Belden
14 3

22645

Belden part 22645 is a Canadian Instrumentation Cable (TC-CIC) rated 300 V RMS, built with one 18 AWG (7x26) tinned copper pair insulated with PVC in black and white color code. It has an overall Beldfoil bi-laminate shield with 100% coverage and a 20 AWG tinned copper drainwire, covered by a black PVC jacket with ripcord, rated 105°C dry / 75°C wet and sunlight resistant to -25°C. It is suitable for indoor/outdoor use and complies with C22.2#239 Type CIC and CEC/C(UL) CIC standards.

Belden
14 3

22685D

Belden 22685D is a Canadian Instrumentation Cable (CIC) rated 300 V, built with 16 pairs of 16 AWG (7x24) tinned copper conductors and XLPE insulation. It uses individual and overall Beldfoil shields with a drain wire, a black PVC jacket with ripcord, and is rated for -40 °C to +90 °C operation (-25 °C to +90 °C installation) with sunlight resistance. It is suitable for CEC power and control applications.

Belden
14 3