Wire Cable Assemblies

35372

Belden part 35372 is an XTRAGUARD 3 cable with two pairs of 18 AWG (16x30) stranded tinned copper conductors, PVC insulation, an overall aluminum/polyester bi-laminate shield at 100% coverage, and a slate polyethylene outer jacket with ripcord. It is rated for 300 V and is intended for data, communication, audio, and low-level signal transmission such as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable operates from -30°C to +80°C, has a nominal overall diameter of 0.330 in (8.38 mm), and is suitable for outdoor and burial applications.

Belden
14 3

35410

The Belden 35410 is a 10 AWG rubber lead wire with 65x28 stranded tinned copper conductor and XLPO thermoset insulation. It is rated for 600 V and 150 °C (125 °C flexing) and is intended for high-temperature internal wiring of appliances and electronic equipment. The wire complies with AWM 3436 and CSA TYPE CL1251 standards.

Belden
14 3

35464

Belden part 35464 is an XTRAGUARD 3 cable with 4 conductors of 20 AWG stranded tinned copper, PVC insulation, an overall aluminum/polyester shield with drainwire, and a slate polyethylene jacket. It is rated for 300 V operation and is designed for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Belden
14 3

24501D

Belden 24501D is a Canadian TC-ACIC 600 V instrumentation cable with one 16 AWG (7x24) tinned copper triad, XLPE insulation, an overall Beldfoil shield, PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated -40 °C to 90 °C wet / 105 °C dry, is sunlight resistant, and carries a 600 V rating with 19 A max current per conductor at 30 °C. Typical end uses include industrial control, raceways and cable trays, digital control, 4-20 mA / 0-10 V instruments, encoders, DCS/PLC systems, and solenoids, valves, actuators, and positioners.

Belden
14 2

24505D

Belden 24505D is a Canadian TC-ACIC 600 V instrumentation cable containing 2 pairs of 16 AWG (7x24) stranded tinned copper conductors with XLPE insulation, individual and overall Beldfoil shielding, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated for -40 °C to 90 °C wet / 105 °C dry service, is sunlight resistant, and is intended for industrial control, raceways, cable trays and ducts, digital control, instrument and process control circuits.

Belden
14 2

28083A

The Belden 28083A is a 5-conductor 14 AWG (7x22 bare copper) power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF) and is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations.

Belden
14 2

28145A

The Belden 28145A is a UL Type TC (1277) power and control cable with nine 10 AWG bare copper conductors (7x18 stranding), PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V, 90°C dry/wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations. A ripcord is included for easier jacket removal.

Belden
14 2

28157A

Belden 28157A is a UL Type TC power and control cable with four 4 AWG bare copper conductors plus one 8 AWG bare copper ground wire, insulated with PVC/nylon and jacketed in black PVC. It is rated 600 V, 90°C dry and wet, and is suitable for indoor, outdoor, sunlight-resistant, UV-resistant, and direct burial installations including Class 1 Division 2 hazardous locations.

Belden
14 2

28171A

The Belden 28171A is a UL Type TC power and control cable with three 2/0 AWG bare copper conductors plus a 6 AWG bare copper ground, PVC/nylon insulation, and a black PVC jacket rated 600 V. It is suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with a 90°C dry/wet temperature rating and sunlight-resistant, direct-burial construction.

Belden
14 2

28329A

Belden 28329A is a UL Type TC (1277) PVC-nylon/PVC multi-conductor cable with 12 conductors of 18 AWG (7x26) bare copper, PVC-nylon E2 color-coded insulation, and a black PVC outer jacket with ripcord. It is rated 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations, with sunlight resistance and direct burial approval.

Belden
14 2

28600A

The Belden 28600A is a 6-conductor 18 AWG (7x26) bare copper cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), with 90 °C dry/wet temperature ratings, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.

Belden
14 2

28629A

The Belden 28629A is a UL Type TC power and control cable containing 37 conductors of 14 AWG (7x22) bare copper with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, and is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.

Belden
14 2

28630A

The Belden 28630A is a 37-conductor, 12 AWG (7x20 stranded bare copper) UL Type TC power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), 90 °C dry/wet, and is suitable for indoor, outdoor, sunlight-resistant, and direct-burial installations including Class 1 Division 2 hazardous locations. The unshielded cable includes a ripcord and has a nominal overall diameter of 1.076 in (27.33 mm).

Belden
14 2

29528

Belden 29528 is a flexible 600/1000 V VFD motor supply cable with three 1 AWG (7x19x22) tinned copper conductors and XLPE insulation, plus a segmented 1 AWG bare copper ground (3 of 6 AWG). It uses dual 100% coverage helical bare copper tape shields and a black PVC jacket with ripcord, rated 90 °C dry/wet for TC-ER and WTTC use. It is intended for variable frequency drives, AC motor and drive systems, and Class 1 Division 2 hazardous locations.

Belden
14 2

30800

Belden part 30800 is a 2/0 AWG (504x26) tinned copper lead wire with silicone rubber insulation and a lacquered glass braid outer jacket. It is rated for 600 V RMS and an operating temperature of -70 °C to +200 °C, intended for Class 130(B), 155(F), or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and high temperature applications.

Belden
14 2

8800

The Belden 8800 is a wire dispensing rack designed for organizational and physical handling of wire spools. It is specifically suitable for the mounting and storage of multiple spools of hook-up wire.

Belden
13 10

27155AS

The Belden 27155AS is a UL Type TC tray cable with two 4 AWG bare copper conductors and one 8 AWG bare copper ground conductor, PVC/nylon insulation, an overall 100% Beldfoil shield, and a black PVC jacket rated 600 V. It is designed for harsh environment digital and serial two-way communication, including oil and gas extraction and refining, petrochemical sites, and Profibus or Foundation FieldBus process automation. It also suits extreme temperature, humidity/moisture, dust, oil, and remote long-distance applications.

Belden
13 8

8869

No description available

Belden
13 7

7824P

No description available

Belden
13 6

29539

Belden 29539 is a 2000 V TC-ER / 1000 V WTTC flexible motor supply cable intended for Variable Frequency Drives (VFD), AC motor and drive systems, and high voltage applications. It uses three 8 AWG tinned copper power conductors plus one 8 AWG tinned copper ground conductor, with XLPE insulation, an overall Beldfoil/tinned copper braid shield, and a black PVC jacket. The cable is rated 90°C dry and wet, is suitable for indoor, outdoor, sunlight, oil resistant, and direct burial use, and meets TC-ER, WTTC, RHW-2, and CIC/TC compliance.

Belden
13 5