2134A
The Belden 2134A is a 600V TC-ER fieldbus cable featuring a 24-pair 16AWG tinned copper conductor with XLPO insulation and dual Beldfoil shields (individual and overall) protected by a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, suitable for oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. It supports extreme temperature environments and long-distance remote applications with exposure to humidity, dust, and oil.
2132A
The Belden 2132A is a 16-pair Fieldbus cable with 16 AWG tinned copper conductors, XLPE insulation, individual and overall Beldfoil shields, and a TPE outer jacket rated for 600V TC-ER. It is designed for harsh environment digital and serial two-way communication, suitable for use in oil and gas extraction, petrochemical environments, Profibus and Foundation FieldBus process automation, and extreme temperature or moisture conditions.
2125A
The Belden 2125A is a 600V TC-ER rated fieldbus cable featuring 24 pairs of 18AWG tinned copper conductors, XLPO insulation, individual and overall Beldfoil shields, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, suitable for Profibus and Foundation FieldBus process automation in extreme temperature, humid, dusty, and oily environments such as oil and gas extraction and petrochemical sites. The cable supports a maximum current of 5.4 Amps per conductor and offers a characteristic impedance of 100 Ohm with a velocity of propagation of 64%.
2121A
The Belden 2121A is an 8-pair 18 AWG tinned copper fieldbus cable with XLPO insulation, individual and overall Beldfoil shields, and a TPE outer jacket, rated for 600V TC-ER. It is designed for harsh environment digital and serial two-way communication in industrial settings such as oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. The cable is built to withstand extreme temperature environments, exposure to humidity, moisture, dust, and oil, as well as long-distance remote applications.
2108A
The Belden 2108A is a 50-pair, 18AWG tinned copper fieldbus cable with XLPE insulation, dual Beldfoil shields, and a TPE outer jacket. It is designed for harsh-environment digital and serial two-way communication, suitable for oil and gas extraction, petrochemical plants, Profibus and Foundation FieldBus process automation, and extreme temperature or moisture-prone environments.
2105A
The Belden 2105A is a 16-pair 18 AWG tinned copper fieldbus cable featuring XLPO insulation, individual and overall Beldfoil shields, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, suitable for oil and gas extraction/refining, petrochemical plants, and Profibus or Foundation FieldBus process automation. The cable operates in temperatures from -40°C to 90°C and offers excellent protection against moisture, dust, oil, and sunlight.
2103A
The Belden 2103A is an 8-pair fieldbus cable featuring 18AWG tinned copper conductors, XLPE insulation, dual Beldfoil shields, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, widely used in oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. This cable is built to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote deployments.
2101A
The Belden 2101A is a 2-pair 18AWG tinned copper fieldbus cable with XLPO insulation, individual and overall Beldfoil shielding, and a TPE outer jacket rated for CMG. It is designed for harsh-environment digital and serial two-way communication, widely used in oil and gas extraction and refining, petrochemical plants, and Profibus or Foundation FieldBus process automation systems under extreme temperatures, humidity, dust, and oil exposure.
2100A
The Belden 2100A is a fieldbus cable featuring one 18AWG tinned copper pair with XLPE insulation, an overall Beldfoil shield, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, suitable for oil and gas extraction, petrochemical sites, and Profibus or Foundation FieldBus process automation.
2005C
The Belden 2005C is an electronic cable featuring four 18 AWG tinned copper conductors with SRPVC insulation, an overall Beldfoil shield, and a PVC outer jacket. It is designed for indoor electronics applications, supporting a maximum conductor current of 4 Amps and a UL voltage rating of 300 V. The cable operates within a temperature range of -20°C to +75°C and has a nominal overall diameter of 0.227 in (5.77 mm).
2146A
The Belden 2146A is a Category 6 premise horizontal cable designed for indoor and outdoor use, supporting Ethernet 10BASE-T, 100BASE-TX, and 1000BASE-T, along with PoE, PoE+, and PoE++ standards. It features four pairs of 23 AWG solid bare copper conductors insulated with polyolefin and jacketed with UV-resistant PVC. The cable has a nominal diameter of 0.255 inches (6.48 mm), a maximum voltage rating of 300 V (CMR/CMX), and operates within a temperature range of -40°C to +75°C.
2137A
The Belden 2137A is a discontinued Category 5e indoor/outdoor OSP cable designed for high-speed data and video transmission. It features four pairs of 24 AWG solid bare copper conductors with polyolefin insulation and a gel-filled, UV-resistant, flame-retardant low-smoke zero-halogen (LSZH) jacket. It supports applications like Gigabit Ethernet, 100BaseTX, ATM, and digital video transmission in harsh outside plant environments.
2131A
The Belden 2131A is a 12-pair, 16 AWG tinned copper fieldbus cable with XLPE insulation, individual and overall Beldfoil shields, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, widely used in oil and gas extraction, petrochemical sites, and Profibus or Foundation FieldBus process automation. The cable is rated for 600V and operates in temperatures ranging from -40°C to 90°C.
2112A
The Belden 2112A is an 8-pair 16AWG tinned copper fieldbus cable featuring XLPO insulation, individual and overall Beldfoil shielding, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, particularly in oil and gas extraction/refining, petrochemical, Profibus, and Foundation FieldBus process automation. It is built to withstand extreme temperatures, humidity, moisture, dust, oil exposure, and long-distance remote applications.
2106A
The Belden 2106A is a 20-pair 18 AWG tinned copper fieldbus cable with cross-linked polyethylene (XLPE) insulation, individual and overall Beldfoil shields, and a thermoplastic elastomer (TPE) outer jacket. It is designed for harsh environment digital and serial two-way communication in oil and gas extraction, petrochemical sites, and Profibus or Foundation FieldBus process automation. It is built to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote applications.
2143A
The Belden 2143A is a Category 6 premise horizontal cable designed for indoor and outdoor use, supporting Ethernet 10BASE-T, 100BASE-TX, and 1000BASE-T, as well as Power over Ethernet (PoE, PoE+, PoE++). It features four pairs of 23 AWG solid bare copper conductors, gel-filled waterblocking, and a UV-resistant, flame-retardant low smoke zero halogen (LSZH) Haloarrest® outer jacket. It is suitable for OSP-outdoor installations and noisy environments, but is not recommended for marine applications.
29554C
Belden 29554C is a 3-conductor 6 AWG (7x14) bare copper VFD cable with XLPE insulation and a symmetrical segmented ground of 3 x 12 AWG (7x20) bare copper. It has an overall dual helically applied bare copper tape shield (100% coverage), a black PVC jacket with ripcord, and is rated 1000 V (CSA TC) for variable frequency drives and AC motor and drive systems in Canada. The cable operates from -40°C to 90°C, has a nominal overall diameter of 0.823 in (20.9 mm), and is suitable for indoor, outdoor, sunlight-resistant, oil-resistant, and direct burial applications.
29541
Belden 29541 is a flexible 2000 V VFD motor supply cable built with three 4 AWG tinned copper conductors and a 4 AWG tinned copper ground, XLPE insulation, Beldfoil® plus tinned copper braid shielding, and a black PVC jacket. It is rated for 90 °C dry/wet operation and is intended for variable frequency drive and AC motor/drive systems in indoor, outdoor, oily, and direct-burial environments.
29561C
Belden 29561C is a CSA-rated VFD power cable intended for variable frequency drives and AC motor and drive systems, with ratings for applications in Canada. It has three 4/0 AWG bare copper stranded conductors with XLPE insulation, three symmetrical segmented 8 AWG bare copper grounds, dual helically applied bare copper tape shields at 100% coverage, and a black PVC jacket rated 1000 V.
29550C
Belden 29550C is a 3-conductor, 14 AWG bare copper VFD power cable with XLPE insulation and a symmetrical segmented 14 AWG bare copper ground (3 of 18 AWG). It uses dual 100% coverage helical bare copper tape shields under a black PVC jacket and is rated 1000 V (CSA TC). It is intended for Variable Frequency Drives (VFD), AC motor and drive systems, and specific applications in Canada.