2106A Datasheet
The Belden 2106A is a 20-pair 18 AWG tinned copper fieldbus cable with cross-linked polyethylene (XLPE) insulation, individual and overall Beldfoil shields, and a thermoplastic elastomer (TPE) outer jacket. It is designed for harsh environment digital and serial two-way communication in oil and gas extraction, petrochemical sites, and Profibus or Foundation FieldBus process automation. It is built to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2106A Key Specifications
- Max. Capacitance Unbalance
- 1.2 pF/ft
- Max. Current
- 5.4 Amps per Conductor
- Nom. Capacitance Cond-to-Cond
- 22 pF/ft (72 pF/m)
- UL Voltage Rating
- 300 V
- Operating Temperature
- -40°C to 90°C
- Bulk Cable Weight
- 734 lbs/1000ft (1090 kg/km)
- Conductor
- 20 pairs, 18 AWG (7x26 stranded TC - Tinned Copper)
- Max. Pull Tension
- 1170 lbs (531 kg)
Characteristics (datasheet)
- Conductor
- 20 pairs, 18 AWG (7x26 stranded TC - Tinned Copper)
- Nominal Characteristic Impedence
- 120 Ohm
- Nom. Capacitance Cond-to-Cond
- 22 pF/ft (72 pF/m)
- Max. Capacitance Unbalance
- 1.2 pF/ft
- Nom. Conductor DCR
- 5.86 Ohm/1000ft (19.2 Ohm/km)
- Max. Current
- 5.4 Amps per Conductor
- UL Voltage Rating
- 300 V
- Operating Temperature
- -40°C to 90°C
- Max. Pull Tension
- 1170 lbs (531 kg)
- Bulk Cable Weight
- 734 lbs/1000ft (1090 kg/km)
2106A Applications
- Harsh environment digital and serial two-way communication
- Oil and gas extraction and refining sites
- Petrochemical
- Profibus process automation or Foundation FieldBus process automation
- Extreme temperature environments
- Exposure to humidity/moisture, dust, and oil
- Remote locations long distance applications
Other Belden parts
- 1710 — The Belden 1710 is a 2-conductor, 22 AWG stranded tinned copper communication an...
- 9333 — The Belden 9333 is a high-performance instrumentation cable featuring 11 pairs o...
- 5540FT — The Belden 5540FT is a thermostat and control cable with a riser-CMR rating, des...
- 86704CY — The Belden 86704CY is an XTRAGUARD FLEX continuous flex data cable featuring 4 p...
- 27082A — The Belden 27082A is a UL Type TC (1277) power and control cable with four 14 AW...
- 31506 — Belden 31506 is a 6 AWG (84x25 stranding) tinned copper lead wire with neoprene...
- 78154 — The Belden 78154 is an ECOCABLE featuring 4 pairs of 28 AWG tinned copper conduc...
- 45552 — The Belden 45552 is an XTRAGUARD 4 two-conductor cable built with 12 AWG (65x30)...
More Bulk Wire Cable
- 80020 — The Belden 80020 is a zero-halogen, flexible 2-conductor 20 AWG tinned copper co...
- 5929 — The Belden 5929 is an XTRAGUARD 1 shielded multi-conductor cable consisting of s...
- 8628 — The Belden 8628 is a heavy-duty electronic cable featuring seven 14 AWG stranded...
- 29511 — Belden 29511 is a flexible 600 V/1000 V motor supply cable built for variable fr...
- 77002 — The Belden 77002 is a 4-conductor, 24 AWG tinned copper cable with mPPE insulati...
- 78239 — The Belden 78239 is a 9-pair, 22 AWG stranded tinned copper ECOCABLE with modifi...
- 1426A — The Belden 1426A is a discontinued RG59 coaxial cable designed primarily for ana...
- 1061A — The Belden 1061A is a 36-pair instrumentation and control cable featuring 20 AWG...
2106A FAQ
What is 2106A?
2106A is a Bulk Wire Cable from Belden. The Belden 2106A is a 20-pair 18 AWG tinned copper fieldbus cable with cross-linked polyethylene (XLPE) insulation, individual and overall Beldfoil shields, and a thermoplastic elastomer (TPE) outer jacket. It is designed for harsh environment digital and serial two-way communication in oil and gas extraction, petrochemical sites, and Profibus or Foundation FieldBus process automation. It is built to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote applications.
Who manufactures 2106A?
2106A is manufactured by Belden.
Where can I download the 2106A datasheet PDF?
The 2106A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2106A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 734 lbs/1000ft (1090 kg/km) |
| Conductor | 20 pairs, 18 AWG (7x26 stranded TC - Tinned Copper) |
| Max. Capacitance Unbalance | 1.2 pF/ft |
| Max. Current | 5.4 Amps per Conductor |
| Max. Pull Tension | 1170 lbs (531 kg) |
| Nom. Capacitance Cond-to-Cond | 22 pF/ft (72 pF/m) |
| Nom. Conductor DCR | 5.86 Ohm/1000ft (19.2 Ohm/km) |
| Nominal Characteristic Impedence | 120 Ohm |
| Operating Temperature | -40°C to 90°C |
| UL Voltage Rating | 300 V |