The Belden 2131A is a 12-pair, 16 AWG tinned copper fieldbus cable with XLPE insulation, individual and overall Beldfoil shields, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, widely used in oil and gas extraction, petrochemical sites, and Profibus or Foundation FieldBus process automation. The cable is rated for 600V and operates in temperatures ranging from -40°C to 90°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2131A Key Specifications
- Max. Current
- 7.2 Amps per Conductor
- UL Voltage Rating
- 600 V (TC-ER), 600 V (CSA CIC Type TC)
- Operating Temperature
- -40°C to 90°C (UL Temperature Operating: 90°C Wet/Dry)
- Bulk Cable Weight
- 666 lbs/1000ft (991 kg/km)
- Characteristic Impedance
- 100 Ohm
- Conductor
- 12 Pair(s), 16 AWG 7x24 TC - Tinned Copper
- Insulation Material
- XLPE - Cross-Linked Polyethylene (Thermoset), 0.038 in (0.97 mm) nominal thickness
- Max. Pull Tension
- 1161 lbs (526.6 kg)
Characteristics (datasheet)
- Conductor
- 12 Pair(s), 16 AWG 7x24 TC - Tinned Copper
- Insulation Material
- XLPE - Cross-Linked Polyethylene (Thermoset), 0.038 in (0.97 mm) nominal thickness
- Shielding
- Individual & Overall Tape Bi-Laminate (Alum+Poly) 100% coverage with 18 AWG (7x26) TC and 16 AWG (7x24) TC drainwires
- Outer Jacket
- TPE - Thermoplastic Elastomer, 0.085 in (2.2 mm) nominal thickness, Ripcord: Yes
- Overall Cable Diameter (Nominal)
- 1.186 in (30.12 mm)
- UL Voltage Rating
- 600 V (TC-ER), 600 V (CSA CIC Type TC)
- Operating Temperature
- -40°C to 90°C (UL Temperature Operating: 90°C Wet/Dry)
- Characteristic Impedance
- 100 Ohm
- Max. Current
- 7.2 Amps per Conductor
- Nom. Conductor DCR
- 4.2 Ohm/1000ft (14 Ohm/km)
- Max. Pull Tension
- 1161 lbs (526.6 kg)
- Bulk Cable Weight
- 666 lbs/1000ft (991 kg/km)
2131A Applications
- harsh environment digital and serial two-way communication
- oil and gas extraction and refining sites
- petrochemical, Profibus process automation or Foundation FieldBus process automation
- extreme temperature environments, exposure to humidity/moisture, dust, and oil
- remote locations long distance applications
Other Belden parts
- 76408TS — The 76408TS is a high-flex MachFlex™ cable consisting of 8 pairs of 28AWG tinned...
- 36101 — Belden part 36101 is a low temperature rubber lead wire built with a 1 AWG (210x...
- 50001L — The Belden 50001L is an RS-485 fire resistant cable with one pair of 22 AWG stra...
- 932794001 — TEST LEAD KIT; Kit Contents:8 x Test Leads, 2 x Clamp Type Test Probes, 2 x Croc...
- 78415 — The Belden 78415 is a 20-conductor, 20 AWG tinned copper ECOCABLE designed for d...
- 934075103 — 1kV 32A Yellow Cable Plug Connector
- 31516 — Belden 31516 is a 16 AWG (26x30) stranded tinned copper lead wire with neoprene...
- 5293C — The Belden 5293C is an XTRAGUARD 1 shielded cable with three 20 AWG tinned coppe...
More Bulk Wire Cable
- 7929A — The Belden 7929A is an industrial Ethernet Cat 5e cable featuring four bonded pa...
- 5198C — The 5198C is an 8-conductor, 22 AWG tinned copper cable with semi-rigid PVC insu...
- 1771 — The Belden 1771 is a communication and control cable with two 23 AWG bare copper...
- 78122 — The Belden 78122 is a shielded multi-conductor cable (ECOCABLE) consisting of tw...
- 78088 — The Belden 78088 is an ECOCABLE consisting of 8 pairs of 22 AWG tinned copper co...
- 9760MN — The Belden 9760MN is a SpaceMaker™ indoor cable consisting of 3 pairs of 16AWG t...
- 8777 — The Belden 8777 is a multi-pair audio, control, and instrument cable consisting...
- 22635 — Belden 22635 is a Canadian Instrumentation Cable (TC-CIC) rated at 300 V, built...
2131A FAQ
What is 2131A?
2131A is a Bulk Wire Cable from Belden. The Belden 2131A is a 12-pair, 16 AWG tinned copper fieldbus cable with XLPE insulation, individual and overall Beldfoil shields, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, widely used in oil and gas extraction, petrochemical sites, and Profibus or Foundation FieldBus process automation. The cable is rated for 600V and operates in temperatures ranging from -40°C to 90°C.
Who manufactures 2131A?
2131A is manufactured by Belden.
Where can I download the 2131A datasheet PDF?
The 2131A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2131A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 666 lbs/1000ft (991 kg/km) |
| Characteristic Impedance | 100 Ohm |
| Conductor | 12 Pair(s), 16 AWG 7x24 TC - Tinned Copper |
| Insulation Material | XLPE - Cross-Linked Polyethylene (Thermoset), 0.038 in (0.97 mm) nominal thickness |
| Max. Current | 7.2 Amps per Conductor |
| Max. Pull Tension | 1161 lbs (526.6 kg) |
| Nom. Conductor DCR | 4.2 Ohm/1000ft (14 Ohm/km) |
| Operating Temperature | -40°C to 90°C (UL Temperature Operating: 90°C Wet/Dry) |
| Outer Jacket | TPE - Thermoplastic Elastomer, 0.085 in (2.2 mm) nominal thickness, Ripcord: Yes |
| Overall Cable Diameter (Nominal) | 1.186 in (30.12 mm) |
| Shielding | Individual & Overall Tape Bi-Laminate (Alum+Poly) 100% coverage with 18 AWG (7x26) TC and 16 AWG (7x24) TC drainwires |
| UL Voltage Rating | 600 V (TC-ER), 600 V (CSA CIC Type TC) |