BeldenBulk Wire Cable

The Belden 2132A is a 16-pair Fieldbus cable with 16 AWG tinned copper conductors, XLPE insulation, individual and overall Beldfoil shields, and a TPE outer jacket rated for 600V TC-ER. It is designed for harsh environment digital and serial two-way communication, suitable for use in oil and gas extraction, petrochemical environments, Profibus and Foundation FieldBus process automation, and extreme temperature or moisture conditions.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

2132A Key Specifications

Max. Current
7.2 Amps per Conductor
Nom. Capacitance Cond-to-Cond
22 pF/ft (72 pF/m)
UL Voltage Rating
600 V (TC-ER), 600 V (CSA CIC Type TC)
Operating Temperature
-40°C to 90°C
UL Temperature
90°C Wet/Dry
Conductor
16 AWG 7x24 TC - Tinned Copper, 16 pairs
Inner Shield
Tape, Bi-Laminate (Alum+Poly), 100% coverage, 18 AWG (7x26) TC drainwire, Individually Shielded
Insulation
XLPE - Cross-Linked Polyethylene (Thermoset), Nom. Thickness 0.038 in (0.97 mm), Color Code Blue, Orange and Numbered

Characteristics (datasheet)

Conductor
16 AWG 7x24 TC - Tinned Copper, 16 pairs
Insulation
XLPE - Cross-Linked Polyethylene (Thermoset), Nom. Thickness 0.038 in (0.97 mm), Color Code Blue, Orange and Numbered
Inner Shield
Tape, Bi-Laminate (Alum+Poly), 100% coverage, 18 AWG (7x26) TC drainwire, Individually Shielded
Outer Shield
Tape, Bi-Laminate (Alum+Poly), 100% coverage, 16 AWG (7x24) TC drainwire
Outer Jacket
TPE - Thermoplastic Elastomer, Nom. Thickness 0.085 in (2.2 mm), Nom. Diameter 1.321 in (33.55 mm), Ripcord Yes
Nom. Conductor DCR
4.2 Ohm/1000ft (14 Ohm/km)
Nom. Characteristic Impedence
100 Ohm
Nom. Capacitance Cond-to-Cond
22 pF/ft (72 pF/m)

Absolute Maximum Ratings

UL Voltage Rating
600 V (TC-ER), 600 V (CSA CIC Type TC)
UL Temperature
90°C Wet/Dry
Operating Temperature
-40°C to 90°C
Max. Pull Tension
1536 lbs (696.7 kg)
Max. Current
7.2 Amps per Conductor

2132A Applications

  • Harsh environment digital and serial two-way communication
  • Oil and gas extraction and refining sites
  • Petrochemical
  • Profibus process automation
  • Foundation FieldBus process automation
  • Extreme temperature environments
  • Exposure to humidity/moisture, dust, and oil
  • Remote locations long distance applications

Other Belden parts

  • 8445 — The Belden 8445 is a 5-conductor electronic cable constructed with 22 AWG tinned...
  • 76022 — The 76022 is a 4-pair 24 AWG bare copper industrial Ethernet cable featuring pol...
  • 7900A — The Belden 7900A is a DeviceBus® cable designed for ODVA DeviceNet™ applications...
  • 9290 — The Belden 9290 is an RG6 coaxial cable designed primarily for analog video tran...
  • 25122 — Belden part 25122 is an XTRAGUARD 2 cable consisting of 2 pairs of 22 AWG (7x30)...
  • 1172A — The Belden 1172A is a flexible, star quad microphone cable designed for low-nois...
  • 3246 — The Belden 3246 is a communication and control cable featuring two 16 AWG tinned...
  • 23554D — Belden 23554D is a Canadian TC-ACIC instrumentation cable with 36 pairs of 18 AW...

More Bulk Wire Cable

  • 75030 — The Belden 75030 is a high-flex Category 5e unshielded twisted pair (UTP) cable...
  • 8747 — The Belden 8747 is a multi-conductor electronic cable featuring 6 pairs of 22 AW...
  • 9439 — The Belden 9439 is a multi-conductor electronic cable featuring seven 20 AWG tin...
  • 9527 — The Belden 9527 is a high-performance instrumentation cable featuring 27 pairs o...
  • 83754 — The Belden 83754 is a high-temperature, high-flexibility 4-conductor 14 AWG cabl...
  • 26501D — Belden part 26501D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, co...
  • 79214 — The Belden 79214 is a 7-conductor 18 AWG tinned copper cable with mPPE insulatio...
  • 28629A — The Belden 28629A is a UL Type TC power and control cable containing 37 conducto...

2132A FAQ

What is 2132A?

2132A is a Bulk Wire Cable from Belden. The Belden 2132A is a 16-pair Fieldbus cable with 16 AWG tinned copper conductors, XLPE insulation, individual and overall Beldfoil shields, and a TPE outer jacket rated for 600V TC-ER. It is designed for harsh environment digital and serial two-way communication, suitable for use in oil and gas extraction, petrochemical environments, Profibus and Foundation FieldBus process automation, and extreme temperature or moisture conditions.

Who manufactures 2132A?

2132A is manufactured by Belden.

Where can I download the 2132A datasheet PDF?

The 2132A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 2132A specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor16 AWG 7x24 TC - Tinned Copper, 16 pairs
Inner ShieldTape, Bi-Laminate (Alum+Poly), 100% coverage, 18 AWG (7x26) TC drainwire, Individually Shielded
InsulationXLPE - Cross-Linked Polyethylene (Thermoset), Nom. Thickness 0.038 in (0.97 mm), Color Code Blue, Orange and Numbered
Max. Current7.2 Amps per Conductor
Max. Pull Tension1536 lbs (696.7 kg)
Nom. Capacitance Cond-to-Cond22 pF/ft (72 pF/m)
Nom. Characteristic Impedence100 Ohm
Nom. Conductor DCR4.2 Ohm/1000ft (14 Ohm/km)
Operating Temperature-40°C to 90°C
Outer JacketTPE - Thermoplastic Elastomer, Nom. Thickness 0.085 in (2.2 mm), Nom. Diameter 1.321 in (33.55 mm), Ripcord Yes
Outer ShieldTape, Bi-Laminate (Alum+Poly), 100% coverage, 16 AWG (7x24) TC drainwire
UL Temperature90°C Wet/Dry
UL Voltage Rating600 V (TC-ER), 600 V (CSA CIC Type TC)