2101A Datasheet
The Belden 2101A is a 2-pair 18AWG tinned copper fieldbus cable with XLPO insulation, individual and overall Beldfoil shielding, and a TPE outer jacket rated for CMG. It is designed for harsh-environment digital and serial two-way communication, widely used in oil and gas extraction and refining, petrochemical plants, and Profibus or Foundation FieldBus process automation systems under extreme temperatures, humidity, dust, and oil exposure.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2101A Key Specifications
- Max. Capacitance Unbalance
- 1.2 pF/ft
- Max. Current
- 8.7 Amps per Conductor
- Nom. Capacitance Cond-to-Cond
- 22 pF/ft (72 pF/m)
- Nom. Inductance
- 0.22 µH/ft (0.72 µH/m)
- UL Voltage Rating
- 300 V
- UL Temperature / Operating Temperature
- 90°C / -40°C to 90°C
- Bulk Cable Weight
- 109 lbs/1000ft (162 kg/km)
- Conductor
- 2 Pair(s) 18 AWG 7x26 TC - Tinned Copper
Characteristics (datasheet)
- Conductor
- 2 Pair(s) 18 AWG 7x26 TC - Tinned Copper
- Insulation
- XLPE - Cross-Linked Polyethylene (Thermoset), 0.032 in (0.81 mm), Blue, Orange and Numbered
- Inner Shield
- Tape, Bi-Laminate (Alum+Poly), 100% coverage
- Outer Shield
- Tape, Bi-Laminate (Alum+Poly), 100% coverage
- Outer Jacket
- TPE - Thermoplastic Elastomer, 0.047 in (1.2 mm) thickness, 0.512 in (13.0 mm) nominal diameter, ripcord Yes
- Nom. Conductor DCR
- 5.86 Ohm/1000ft (19.2 Ohm/km)
- Nom. Capacitance Cond-to-Cond
- 22 pF/ft (72 pF/m)
- Max. Capacitance Unbalance
- 1.2 pF/ft
- Nom. Characteristic Impedence
- 100 Ohm
- Nom. Velocity of Prop.
- 64%
- Nom. Inductance
- 0.22 µH/ft (0.72 µH/m)
- Max. Current
- 8.7 Amps per Conductor
- UL Voltage Rating
- 300 V
- UL Temperature / Operating Temperature
- 90°C / -40°C to 90°C
- Max. Pull Tension
- 137 lbs (62.1 kg)
- Bulk Cable Weight
- 109 lbs/1000ft (162 kg/km)
2101A Applications
- harsh environment digital and serial two-way communication
- oil and gas extraction and refining sites
- petrochemical
- Profibus process automation
- Foundation FieldBus process automation
- extreme temperature environments
- exposure to humidity/moisture, dust, and oil
- remote locations long distance applications
Other Belden parts
- 5264C — The Belden 5264C is a 4-pair 24 AWG tinned copper cable with semi-rigid PVC insu...
- 1072 — The Belden 1072 is a 12-conductor, 16 AWG tinned copper control cable with PVC i...
- 5506FE — The Belden 5506FE is a security and sound cable rated for riser (CMR) applicatio...
- 7933A — The Belden 7933A is a DataTuff Category 5e industrial Ethernet cable featuring t...
- 5425 — The Belden 5425 is a multi-conductor, 18 AWG tinned copper cable with PVC insula...
- 70010PU — The 70010PU is a PROFINET Type R high-flexibility cable featuring 4 conductors m...
- 1701A — The Belden 1701A is a Category 5E+ premise horizontal cable with 4 bonded pairs...
- 7035 — The Belden 7035 is a single-conductor hook-up wire featuring 14 AWG tinned coppe...
More Bulk Wire Cable
- 80050 — The 80050 is a 36-conductor, 16 AWG tinned copper cable with MPPE insulation and...
- 77121 — The Belden 77121 is a 12-conductor, 18 AWG tinned copper cable with modified pol...
- 5695 — The Belden 5695 is a shielded, semi-rigid PVC multi-conductor cable with 2 pairs...
- 9412 — The Belden 9412 is a high-performance instrumentation cable containing one pair...
- 55364 — The Belden 55364 is a high-performance, shielded 4-conductor cable made of 16 AW...
- 78374 — The Belden 78374 is a multi-conductor ECOCABLE featuring 4 pairs of 24 AWG stran...
- 5922 — The Belden 5922 is an XTRAGUARD 1, 4-conductor 28 AWG tinned copper cable with s...
- 78145 — The Belden 78145 is an ECOCABLE consisting of 5 pairs of 20 AWG tinned copper co...
2101A FAQ
What is 2101A?
2101A is a Bulk Wire Cable from Belden. The Belden 2101A is a 2-pair 18AWG tinned copper fieldbus cable with XLPO insulation, individual and overall Beldfoil shielding, and a TPE outer jacket rated for CMG. It is designed for harsh-environment digital and serial two-way communication, widely used in oil and gas extraction and refining, petrochemical plants, and Profibus or Foundation FieldBus process automation systems under extreme temperatures, humidity, dust, and oil exposure.
Who manufactures 2101A?
2101A is manufactured by Belden.
Where can I download the 2101A datasheet PDF?
The 2101A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2101A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 109 lbs/1000ft (162 kg/km) |
| Conductor | 2 Pair(s) 18 AWG 7x26 TC - Tinned Copper |
| Inner Shield | Tape, Bi-Laminate (Alum+Poly), 100% coverage |
| Insulation | XLPE - Cross-Linked Polyethylene (Thermoset), 0.032 in (0.81 mm), Blue, Orange and Numbered |
| Max. Capacitance Unbalance | 1.2 pF/ft |
| Max. Current | 8.7 Amps per Conductor |
| Max. Pull Tension | 137 lbs (62.1 kg) |
| Nom. Capacitance Cond-to-Cond | 22 pF/ft (72 pF/m) |
| Nom. Characteristic Impedence | 100 Ohm |
| Nom. Conductor DCR | 5.86 Ohm/1000ft (19.2 Ohm/km) |
| Nom. Inductance | 0.22 µH/ft (0.72 µH/m) |
| Nom. Velocity of Prop. | 64% |
| Outer Jacket | TPE - Thermoplastic Elastomer, 0.047 in (1.2 mm) thickness, 0.512 in (13.0 mm) nominal diameter, ripcord Yes |
| Outer Shield | Tape, Bi-Laminate (Alum+Poly), 100% coverage |
| UL Temperature / Operating Temperature | 90°C / -40°C to 90°C |
| UL Voltage Rating | 300 V |