2134A Datasheet

BeldenBulk Wire Cable

The Belden 2134A is a 600V TC-ER fieldbus cable featuring a 24-pair 16AWG tinned copper conductor with XLPO insulation and dual Beldfoil shields (individual and overall) protected by a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, suitable for oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. It supports extreme temperature environments and long-distance remote applications with exposure to humidity, dust, and oil.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

2134A Key Specifications

Max. Current
7.2 Amps per Conductor
UL Voltage Rating
600 V
Operating Temperature
-40°C to 90°C (UL Temperature: 90°C)
Bulk Cable Weight
1219 lbs/1000ft (1814 kg/km)
Conductor
24 Pair 16 AWG (7x24 stranded) Tinned Copper (TC)
Max. Pull Tension
2286 lbs (1037 kg)
Nominal Characteristic Impedance
100 Ohm
Nominal Outer Diameter
1.638 in

Characteristics (datasheet)

Conductor
24 Pair 16 AWG (7x24 stranded) Tinned Copper (TC)
Nominal Characteristic Impedance
100 Ohm
Max. Current
7.2 Amps per Conductor
UL Voltage Rating
600 V
Operating Temperature
-40°C to 90°C (UL Temperature: 90°C)
Max. Pull Tension
2286 lbs (1037 kg)
Bulk Cable Weight
1219 lbs/1000ft (1814 kg/km)
Nominal Outer Diameter
1.638 in

2134A Applications

  • harsh environment digital and serial two-way communication
  • oil and gas extraction and refining sites
  • petrochemical
  • Profibus process automation or Foundation FieldBus process automation
  • extreme temperature environments
  • remote locations long distance applications

Other Belden parts

  • 8773 — The Belden 8773 is a multi-pair audio, control, and instrument cable consisting...
  • 78224 — The Belden 78224 is a 4-pair 24 AWG tinned copper ECOCABLE featuring modified po...
  • 1716 — The Belden 1716 is a 5-conductor, 20 AWG tinned copper communication and control...
  • 9328 — The Belden 9328 is a high-performance instrumentation cable consisting of two pa...
  • 934075102 — Blue 1kV 32A Cable Plug Connector
  • 70046 — The Belden 70046 is a flexible, low smoke zero halogen (LSZH) speaker cable with...
  • 2146A — The Belden 2146A is a Category 6 premise horizontal cable designed for indoor an...
  • 57008 — The Belden 57008 is a plenum-rated, 8-conductor 24 AWG bare copper communication...

More Bulk Wire Cable

  • 1485A — The Belden 1485A is an UL-listed instrumentation cable featuring 8 pairs of 16 A...
  • 28126A — The Belden 28126A is a UL Type TC (1277) cable with 19 conductors of 12 AWG (7x2...
  • 83000 — The 83000 is a high-temperature plastic lead wire featuring a 30 AWG silver-plat...
  • 21593 — The Belden 21593 is a Canadian Instrumentation Cable (TC-CIC) rated 600 V for CE...
  • 28339A — The Belden 28339A is a 5-conductor, 16 AWG (7x24) bare copper power and control...
  • 6226C — The Belden 6226C is a low-voltage communication and control cable featuring 6 pa...
  • 76703TS — The 76703TS is a MachFlex™ high-flexibility cable designed for continuous flexin...
  • 8437 — The Belden 8437 is a single twisted pair audio, control, and instrumentation cab...

2134A FAQ

What is 2134A?

2134A is a Bulk Wire Cable from Belden. The Belden 2134A is a 600V TC-ER fieldbus cable featuring a 24-pair 16AWG tinned copper conductor with XLPO insulation and dual Beldfoil shields (individual and overall) protected by a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, suitable for oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. It supports extreme temperature environments and long-distance remote applications with exposure to humidity, dust, and oil.

Who manufactures 2134A?

2134A is manufactured by Belden.

Where can I download the 2134A datasheet PDF?

The 2134A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 2134A specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk Cable Weight1219 lbs/1000ft (1814 kg/km)
Conductor24 Pair 16 AWG (7x24 stranded) Tinned Copper (TC)
Max. Current7.2 Amps per Conductor
Max. Pull Tension2286 lbs (1037 kg)
Nominal Characteristic Impedance100 Ohm
Nominal Outer Diameter1.638 in
Operating Temperature-40°C to 90°C (UL Temperature: 90°C)
UL Voltage Rating600 V