2112A Datasheet
The Belden 2112A is an 8-pair 16AWG tinned copper fieldbus cable featuring XLPO insulation, individual and overall Beldfoil shielding, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, particularly in oil and gas extraction/refining, petrochemical, Profibus, and Foundation FieldBus process automation. It is built to withstand extreme temperatures, humidity, moisture, dust, oil exposure, and long-distance remote applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2112A Key Specifications
- Max. current
- 10.1 Amps per Conductor
- Nominal capacitance (cond-to-cond)
- 22 pF/ft (72 pF/m)
- UL Voltage Rating
- 300 V
- Operating temperature range
- -40°C to 90°C (UL temperature 90°C)
- Bulk cable weight
- 478 lbs/1000ft (711 kg/km)
- Characteristic impedance
- 100 Ohm
- Conductor configuration
- 8 pairs, 16 AWG (7x24) tinned copper
- Max. pull tension
- 786 lbs (357 kg)
Characteristics (datasheet)
- Conductor configuration
- 8 pairs, 16 AWG (7x24) tinned copper
- Characteristic impedance
- 100 Ohm
- Nominal capacitance (cond-to-cond)
- 22 pF/ft (72 pF/m)
- Max. current
- 10.1 Amps per Conductor
- UL Voltage Rating
- 300 V
- Operating temperature range
- -40°C to 90°C (UL temperature 90°C)
- Max. pull tension
- 786 lbs (357 kg)
- Bulk cable weight
- 478 lbs/1000ft (711 kg/km)
2112A Applications
- Harsh environment digital and serial two-way communication
- Oil and gas extraction and refining sites
- Petrochemical
- Profibus process automation
- Foundation FieldBus process automation
- Extreme temperature environments
- Exposure to humidity/moisture, dust, and oil
- Remote locations long distance applications
Other Belden parts
- 8303 — The Belden 8303 is a computer EIA RS-232 cable designed for extended distance ap...
- 57010 — The Belden 57010 is a plenum-rated, shielded communication and control cable fea...
- 80041 — The Belden 80041 is a zero-halogen, 2-conductor 16 AWG tinned copper cable with...
- 25076 — Belden 25076 is a 6-conductor XTRAGUARD 2 cable with 16 AWG (19x29) stranded tin...
- 23522D — The Belden 23522D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, bui...
- 6394 — The Belden 6394 is a shielded multi-pair communication and control cable featuri...
- 78762ELZ — The Belden 78762ELZ is a 2-conductor 20 AWG tinned copper electronic cable featu...
- 37116 — Belden 37116 is a 16 AWG rubber lead wire with a 26x30 stranded tinned copper co...
More Bulk Wire Cable
- 55272 — Belden part 55272 is an XTRAGUARD 5 cable built with two pairs of 24 AWG (7x32)...
- 80054 — The Belden 80054 is a 5-conductor, 14 AWG tinned copper cable with mPPE insulati...
- 1058A — The Belden 1058A is a UL-listed instrumentation cable featuring 12 pairs of 20 A...
- 83503 — The Belden 83503 is a high-temperature, shielded 3-conductor electronic cable fe...
- 31014 — The Belden 31014 is a 14 AWG stranded tinned copper lead wire with XLPO/XLP/XLPE...
- 8880MN — The Belden 8880MN is a SpaceMaker™ 12-conductor cable featuring 20 AWG tinned co...
- 2146A — The Belden 2146A is a Category 6 premise horizontal cable designed for indoor an...
- 9165 — The Belden 9165 is a composite cable designed for ENG, EFP, and CCTV application...
2112A FAQ
What is 2112A?
2112A is a Bulk Wire Cable from Belden. The Belden 2112A is an 8-pair 16AWG tinned copper fieldbus cable featuring XLPO insulation, individual and overall Beldfoil shielding, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, particularly in oil and gas extraction/refining, petrochemical, Profibus, and Foundation FieldBus process automation. It is built to withstand extreme temperatures, humidity, moisture, dust, oil exposure, and long-distance remote applications.
Who manufactures 2112A?
2112A is manufactured by Belden.
Where can I download the 2112A datasheet PDF?
The 2112A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2112A specifications
Click to ask a quick question:
Parameters
| Bulk cable weight | 478 lbs/1000ft (711 kg/km) |
| Characteristic impedance | 100 Ohm |
| Conductor configuration | 8 pairs, 16 AWG (7x24) tinned copper |
| Max. current | 10.1 Amps per Conductor |
| Max. pull tension | 786 lbs (357 kg) |
| Nominal capacitance (cond-to-cond) | 22 pF/ft (72 pF/m) |
| Operating temperature range | -40°C to 90°C (UL temperature 90°C) |
| UL Voltage Rating | 300 V |