Belden part 25382 is XTRAGUARD 2, a 2-conductor 18 AWG (16/30) tinned copper cable with PVC insulation, an overall aluminum/polyester shield (100% coverage) with drainwire, and a slate polyurethane (TPU) outer jacket. It is rated 300 V under UL AWM/STYLE 20668 (90 °C) and AWM/STYLE 1569 (105 °C), with CSA AWM I/II A/B and FT1/VW-1 flammability ratings. It is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
25382 Key Specifications
- Nominal capacitance
- 50 pF/ft (160 pF/m) conductor-to-conductor; 90 pF/ft (300 pF/m) conductor-to-other
- Nominal characteristic impedance / inductance
- 42 Ohm; 0.18 µH/ft (0.59 µH/m)
- Voltage / temperature ratings
- 300 V (AWM 20668), 300 V (CSA AWM); UL temperature 105°C; operating -30°C To +90°C
- Conductors
- 2, 18 AWG 16x30 TC - Tinned Copper
- Insulation
- PVC, 0.016 in (0.41 mm) nominal thickness, 0.079 in (2.0 mm) nominal diameter, black/red
- Outer jacket
- PUR - Polyurethane, 0.032 in (0.81 mm) nominal thickness, 0.230 in (5.84 mm) nominal diameter, ripcord yes
- Overall cable diameter
- 0.230 in (5.84 mm)
- Shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, 18 AWG (16x30) TC drainwire
Characteristics (datasheet)
- Conductors
- 2, 18 AWG 16x30 TC - Tinned Copper
- Insulation
- PVC, 0.016 in (0.41 mm) nominal thickness, 0.079 in (2.0 mm) nominal diameter, black/red
- Shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, 18 AWG (16x30) TC drainwire
- Outer jacket
- PUR - Polyurethane, 0.032 in (0.81 mm) nominal thickness, 0.230 in (5.84 mm) nominal diameter, ripcord yes
- Overall cable diameter
- 0.230 in (5.84 mm)
- Nominal capacitance
- 50 pF/ft (160 pF/m) conductor-to-conductor; 90 pF/ft (300 pF/m) conductor-to-other
- Nominal characteristic impedance / inductance
- 42 Ohm; 0.18 µH/ft (0.59 µH/m)
- Voltage / temperature ratings
- 300 V (AWM 20668), 300 V (CSA AWM); UL temperature 105°C; operating -30°C To +90°C
25382 Applications
- Data transmission
- Communication
- Audio
- Low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 5205UE — The Belden 5205UE is a security and sound riser-CMR cable featuring seven 16 AWG...
- 9534 — The Belden 9534 is a computer EIA RS-232 cable designed for data transmission, l...
- 1477A — The Belden 1477A is a UL-listed instrumentation cable with 12 pairs of 18 AWG an...
- 79249 — The part 79249 is an ECOFLEX multi-conductor cable consisting of 10 conductors o...
- 78053 — The Belden 78053 is a high-flexibility, 3-pair 28 AWG tinned copper communicatio...
- 74003 — The Belden 74003 is a 2-pair, 26 AWG bare copper industrial Ethernet cable with...
- 9804 — The Belden 9804 is a low-capacitance, overall shielded computer EIA RS-232/422 c...
- 28605A — The Belden 28605A is a UL Type TC (1277) power and control cable with 15 bare co...
More Bulk Wire Cable
- 79213 — The part 79213 is a 5-conductor, 18 AWG tinned copper cable with mPPE insulation...
- 2628 — The Belden 2628 is a single-conductor hook-up wire featuring a 28 AWG nickel-pla...
- 5473C — The Belden 5473C is a shielded, 3-pair 24 AWG tinned copper communication and co...
- 75030 — The Belden 75030 is a high-flex Category 5e unshielded twisted pair (UTP) cable...
- 87740 — The Belden 87740 is a high-temperature, 2-conductor 18 AWG tinned copper electro...
- 74035PU — The Belden 74035PU is a high-flexible, double-shielded single pair Ethernet (SPE...
- 1751 — The Belden 1751 is a 3-conductor 14 AWG tinned copper control and communication...
- 3049 — The Belden 3049 is a single-conductor hook-up wire constructed of 26 AWG strande...
25382 FAQ
What is 25382?
25382 is a Bulk Wire Cable from Belden. Belden part 25382 is XTRAGUARD 2, a 2-conductor 18 AWG (16/30) tinned copper cable with PVC insulation, an overall aluminum/polyester shield (100% coverage) with drainwire, and a slate polyurethane (TPU) outer jacket. It is rated 300 V under UL AWM/STYLE 20668 (90 °C) and AWM/STYLE 1569 (105 °C), with CSA AWM I/II A/B and FT1/VW-1 flammability ratings. It is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
Who manufactures 25382?
25382 is manufactured by Belden.
Where can I download the 25382 datasheet PDF?
The 25382 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 25382 specifications
Click to ask a quick question:
Parameters
| Conductors | 2, 18 AWG 16x30 TC - Tinned Copper |
| Insulation | PVC, 0.016 in (0.41 mm) nominal thickness, 0.079 in (2.0 mm) nominal diameter, black/red |
| Nominal capacitance | 50 pF/ft (160 pF/m) conductor-to-conductor; 90 pF/ft (300 pF/m) conductor-to-other |
| Nominal characteristic impedance / inductance | 42 Ohm; 0.18 µH/ft (0.59 µH/m) |
| Outer jacket | PUR - Polyurethane, 0.032 in (0.81 mm) nominal thickness, 0.230 in (5.84 mm) nominal diameter, ripcord yes |
| Overall cable diameter | 0.230 in (5.84 mm) |
| Shield | Bi-Laminate (Alum+Poly) tape, 100% coverage, 18 AWG (16x30) TC drainwire |
| Voltage / temperature ratings | 300 V (AWM 20668), 300 V (CSA AWM); UL temperature 105°C; operating -30°C To +90°C |