80002 Datasheet
The Belden 80002 is a zero-halogen, 3-conductor 28 AWG tinned copper cable with mPPE insulation and a slate polyurethane outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for 600 V and offers robust resistance to oil, sunlight, and temperature extremes for indoor and outdoor applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
80002 Key Specifications
- Nom. Capacitance Cond-to-Cond
- 15.5 pF/ft (50.9 pF/m)
- Nom. Inductance
- 0.21 µH/ft (0.69 µH/m)
- Voltage rating
- 600 V (AWM 11231, AWM 21959 / CSA AWM)
- Temperature range
- Operating: -50°C to +90°C; Installation: -40°C to +80°C; UL Temperature: 105°C
- Conductor size and material
- 28 AWG (19x40) TC - Tinned Copper, 3 conductors
- Max. pull tension
- 38 lbs (17 kg)
- Min. bend radius (stationary)
- 1.5 in (38 mm)
- Overall cable diameter (nominal)
- 0.146 in (3.71 mm)
Characteristics (datasheet)
- Conductor size and material
- 28 AWG (19x40) TC - Tinned Copper, 3 conductors
- Voltage rating
- 600 V (AWM 11231, AWM 21959 / CSA AWM)
- Nom. Capacitance Cond-to-Cond
- 15.5 pF/ft (50.9 pF/m)
- Nom. Inductance
- 0.21 µH/ft (0.69 µH/m)
- Overall cable diameter (nominal)
- 0.146 in (3.71 mm)
- Temperature range
- Operating: -50°C to +90°C; Installation: -40°C to +80°C; UL Temperature: 105°C
- Min. bend radius (stationary)
- 1.5 in (38 mm)
- Max. pull tension
- 38 lbs (17 kg)
80002 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 9329 — The Belden 9329 is a high-performance instrumentation cable consisting of three...
- 77115 — The Belden 77115 is a 12-conductor 20 AWG tinned copper ECOCABLE featuring mPPE...
- 8405 — The Belden 8405 is a high-quality 5-conductor 20 AWG tinned copper microphone ca...
- 29552C — The Belden 29552C is a CSA Type TC VFD power cable built for variable frequency...
- 9519 — The Belden 9519 is a computer EIA RS-232 cable featuring 19 twisted pairs of 24...
- 934059101 — HIRSCHMANN TEST AND MEASUREMENT 934059101 Test Lead, 4mm Banana Plug to 4mm...
- 5580C — The Belden 5580C is a 5-conductor, 22 AWG tinned copper cable with semi-rigid PV...
- 8668 — The Belden 8668 is a tinned copper braid conductor with a size of 13.3 AWG (120x...
More Bulk Wire Cable
- 5311C — The 5311C is an XTRAGUARD 1 shielded multi-conductor cable featuring 7 conductor...
- 86225CY — The Belden 86225CY is a 25-conductor, 24 AWG tinned copper XTRAGUARD FLEX contin...
- 78340 — The Belden 78340 is a 10-conductor, 22 AWG stranded tinned copper ECOCABLE featu...
- 5486C — The Belden 5486C is a XTRAGUARD 1 shielded multi-conductor cable featuring 6 pai...
- 45122 — Belden 45122 is an XTRAGUARD 4 cable containing 2 pairs of 22 AWG (7x30) strande...
- 2254 — The Belden 2254 is a communication and control cable consisting of two 22 AWG ti...
- 77055 — The Belden 77055 is a 6-conductor, 28 AWG stranded tinned copper ECOCABLE with M...
- 7450WS — The Belden 7450WS is a high-flexibility MachFlex™ cable designed for continuous...
80002 FAQ
What is 80002?
80002 is a Bulk Wire Cable from Belden. The Belden 80002 is a zero-halogen, 3-conductor 28 AWG tinned copper cable with mPPE insulation and a slate polyurethane outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for 600 V and offers robust resistance to oil, sunlight, and temperature extremes for indoor and outdoor applications.
Who manufactures 80002?
80002 is manufactured by Belden.
Where can I download the 80002 datasheet PDF?
The 80002 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 80002 specifications
Click to ask a quick question:
Parameters
| Conductor size and material | 28 AWG (19x40) TC - Tinned Copper, 3 conductors |
| Max. pull tension | 38 lbs (17 kg) |
| Min. bend radius (stationary) | 1.5 in (38 mm) |
| Nom. Capacitance Cond-to-Cond | 15.5 pF/ft (50.9 pF/m) |
| Nom. Inductance | 0.21 µH/ft (0.69 µH/m) |
| Overall cable diameter (nominal) | 0.146 in (3.71 mm) |
| Temperature range | Operating: -50°C to +90°C; Installation: -40°C to +80°C; UL Temperature: 105°C |
| Voltage rating | 600 V (AWM 11231, AWM 21959 / CSA AWM) |