9329 Datasheet
The Belden 9329 is a high-performance instrumentation cable consisting of three individually shielded 22 AWG tinned copper pairs with PVC insulation and a PVC outer jacket. It is rated for 300 V (PLTC, CMG) and designed for use in industrial environments for instrumentation, sensors, valves, positioners, and standard 4-20mA / 0-10V signal transmission. It supports an operating temperature range of -30°C to +105°C and offers robust shielding and mechanical durability with a minimum bend radius of 3.4 inches.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
9329 Key Specifications
- Max. Current
- 3.4 Amps per Conductor at 25ºC
- Nom. Capacitance Cond-to-Cond
- 26 pF/ft (85 pF/m)
- UL Voltage Rating
- 300 V (PLTC, CMG)
- Operating Temperature
- -30°C to +105°C
- Conductor
- 3 pairs, 22 AWG 7x30 stranded tinned copper (TC)
- Min. Bend Radius (Stationary/Installation)
- 3.4 in (86 mm)
- Nom. Conductor DCR
- 18.2 Ohm/1000ft
- Nominal Overall Diameter
- 0.341 in (8.66 mm)
Characteristics (datasheet)
- Conductor
- 3 pairs, 22 AWG 7x30 stranded tinned copper (TC)
- Nominal Overall Diameter
- 0.341 in (8.66 mm)
- Nom. Conductor DCR
- 18.2 Ohm/1000ft
- Nom. Capacitance Cond-to-Cond
- 26 pF/ft (85 pF/m)
- Max. Current
- 3.4 Amps per Conductor at 25ºC
- UL Voltage Rating
- 300 V (PLTC, CMG)
- Operating Temperature
- -30°C to +105°C
- Min. Bend Radius (Stationary/Installation)
- 3.4 in (86 mm)
9329 Applications
- Instrumentation
- Sensors
- Valves
- Positioners
Other Belden parts
- 6312 — The Belden 6312 is a 50-conductor, 24 AWG tinned copper communication and contro...
- 78413 — The Belden 78413 is a 20-conductor, 24 AWG tinned copper ECOCABLE with modified...
- 5328UL — The Belden 5328UL is a fire alarm cable with a riser classification (FPLR), cons...
- 29507 — Belden 29507 is a flexible 600/1000 V TC-ER WTTC motor supply cable built with t...
- 5166C — The Belden 5166C is a shielded, 6-conductor 18 AWG tinned copper cable with PVC...
- 9698MN — The 9698MN is a SpaceMaker™ multi-pair cable consisting of 6 pairs of 24AWG tinn...
- 8083 — The Belden 8083 is a class 200 magnet wire featuring a 34 AWG solid bare copper...
- 79842ELZ — The 79842ELZ is a dual-pair, 24 AWG stranded tinned copper conductor cable with...
More Bulk Wire Cable
- 6039C — The Belden 6039C is a communication and control cable consisting of 9 pairs of 2...
- 29550C — Belden 29550C is a 3-conductor, 14 AWG bare copper VFD power cable with XLPE ins...
- 55123 — The Belden 55123 (XTRAGUARD 5) is a high-performance, 3-pair, 22 AWG shielded ca...
- 78208 — The part 78208 is an ECOCABLE consisting of 8 pairs of 28 AWG stranded tinned co...
- 9395 — The Belden 9395 is a single-conductor 18 AWG stranded tinned copper cable with E...
- 1387 — The Belden 1387 is a heavy-duty RWU90 power and control cable rated for 1000 V,...
- 6000FE — The Belden 6000FE is a plenum-rated security and sound cable designed for indoor...
- 78229 — The Belden 78229 is a 9-pair 24 AWG tinned copper cable (ECOCABLE) with modified...
9329 FAQ
What is 9329?
9329 is a Bulk Wire Cable from Belden. The Belden 9329 is a high-performance instrumentation cable consisting of three individually shielded 22 AWG tinned copper pairs with PVC insulation and a PVC outer jacket. It is rated for 300 V (PLTC, CMG) and designed for use in industrial environments for instrumentation, sensors, valves, positioners, and standard 4-20mA / 0-10V signal transmission. It supports an operating temperature range of -30°C to +105°C and offers robust shielding and mechanical durability with a minimum bend radius of 3.4 inches.
Who manufactures 9329?
9329 is manufactured by Belden.
Where can I download the 9329 datasheet PDF?
The 9329 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 9329 specifications
Click to ask a quick question:
Parameters
| Conductor | 3 pairs, 22 AWG 7x30 stranded tinned copper (TC) |
| Max. Current | 3.4 Amps per Conductor at 25ºC |
| Min. Bend Radius (Stationary/Installation) | 3.4 in (86 mm) |
| Nom. Capacitance Cond-to-Cond | 26 pF/ft (85 pF/m) |
| Nom. Conductor DCR | 18.2 Ohm/1000ft |
| Nominal Overall Diameter | 0.341 in (8.66 mm) |
| Operating Temperature | -30°C to +105°C |
| UL Voltage Rating | 300 V (PLTC, CMG) |