5486C Datasheet
The Belden 5486C is a XTRAGUARD 1 shielded multi-conductor cable featuring 6 pairs of 22 AWG stranded tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V with an operating temperature range of -35 °C to +105 °C, offering a nominal characteristic impedance of 78 Ohm. This cable is designed for industrial control systems, raceways, cable trays, instrumentation circuits, analog and digital signals, and PLC/DCS systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5486C Key Specifications
- Nominal capacitance (cond-to-cond)
- 24.2 pF/ft (79.4 pF/m)
- Voltage rating
- 300 V (CM, CMG, AWM 2464, AWM 2517)
- Operating temperature
- -35 °C to +105 °C (UL temperature 105 °C)
- Characteristic impedance
- 78 Ohm nominal
- Conductor structure
- 6 pairs of 22 AWG (7x30) tinned copper (TC)
- Max. pull tension
- 11 lbs (5.0 kg)
- Nominal overall diameter
- 0.320 in (8.13 mm)
- Shield type
- Overall aluminum/polyester tape (100% coverage) with 22 AWG TC drain wire
Characteristics (datasheet)
- Conductor structure
- 6 pairs of 22 AWG (7x30) tinned copper (TC)
- Voltage rating
- 300 V (CM, CMG, AWM 2464, AWM 2517)
- Operating temperature
- -35 °C to +105 °C (UL temperature 105 °C)
- Characteristic impedance
- 78 Ohm nominal
- Nominal capacitance (cond-to-cond)
- 24.2 pF/ft (79.4 pF/m)
- Shield type
- Overall aluminum/polyester tape (100% coverage) with 22 AWG TC drain wire
- Nominal overall diameter
- 0.320 in (8.13 mm)
- Max. pull tension
- 11 lbs (5.0 kg)
5486C Applications
- Industrial control systems, raceways, cable trays, and ducts
- instrumentation and control circuits
- analog and digital signals (4–20 mA, 0–10 V)
- PLC and DCS systems
- sensors, encoders, solenoids, valves, actuators, and positioners
Other Belden parts
- 58124 — The Belden 58124 is a plenum-rated communication and control cable featuring fou...
- 8808 — The Belden 8808 is an unshielded speaker cable featuring a twisted pair of 8 AWG...
- 83612 — The Belden 83612 is a high-temperature, plenum-rated (CMP) electronic cable feat...
- 3088A — The 3088A is a UL-listed instrumentation cable with one pair of 18 AWG bare copp...
- 45523 — Belden 45523 is an XTRAGUARD 4, 3-conductor 18 AWG (16x30) stranded tinned coppe...
- 6059 — The Belden 6059 is a Teck90 600V power and control cable designed for use in CEC...
- 78013 — The Belden 78013 is a 3-conductor 26 AWG tinned copper cable with modified polyp...
- 6414 — The Belden 6414 is a shielded communication and control cable consisting of 3 pa...
More Bulk Wire Cable
- 45481 — Belden part 45481 is an XTRAGUARD 4 cable consisting of one pair of 22 AWG (7x30...
- 86705CY — The Belden 86705CY is an XTRAGUARD FLEX continuous flex data cable featuring fiv...
- 78040 — The Belden 78040 is a multi-conductor cable (ECOCABLE) featuring 10 conductors o...
- 75034 — The Belden 75034 is a high-flex Category 5e shielded twisted pair cable with two...
- 6388 — The Belden 6388 is a 12-pair, 24 AWG shielded communication and control cable fe...
- 45275 — Belden part 45275 is an XTRAGUARD 4 cable containing 5 pairs of 24 AWG (7x32) st...
- 3091A — The Belden 3091A is a UL-listed instrumentation cable featuring a single 16 AWG...
- 5401FE — The Belden 5401FE is a security and commercial audio cable rated for riser-CMR a...
5486C FAQ
What is 5486C?
5486C is a Bulk Wire Cable from Belden. The Belden 5486C is a XTRAGUARD 1 shielded multi-conductor cable featuring 6 pairs of 22 AWG stranded tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V with an operating temperature range of -35 °C to +105 °C, offering a nominal characteristic impedance of 78 Ohm. This cable is designed for industrial control systems, raceways, cable trays, instrumentation circuits, analog and digital signals, and PLC/DCS systems.
Who manufactures 5486C?
5486C is manufactured by Belden.
Where can I download the 5486C datasheet PDF?
The 5486C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5486C specifications
Click to ask a quick question:
Parameters
| Characteristic impedance | 78 Ohm nominal |
| Conductor structure | 6 pairs of 22 AWG (7x30) tinned copper (TC) |
| Max. pull tension | 11 lbs (5.0 kg) |
| Nominal capacitance (cond-to-cond) | 24.2 pF/ft (79.4 pF/m) |
| Nominal overall diameter | 0.320 in (8.13 mm) |
| Operating temperature | -35 °C to +105 °C (UL temperature 105 °C) |
| Shield type | Overall aluminum/polyester tape (100% coverage) with 22 AWG TC drain wire |
| Voltage rating | 300 V (CM, CMG, AWM 2464, AWM 2517) |