7450WS Datasheet
The Belden 7450WS is a high-flexibility MachFlex™ cable designed for continuous flexing and robotics applications. It features a 3+1 conductor layout of 8 AWG bare copper wires insulated in PVC/Nylon, shielded by an 85% tinned copper braid, and jacketed with TPE inner and outer jackets. The cable is rated for 1000V WTTC and 600V TC-ER, with an operating temperature range of -40°C to +105°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
7450WS Key Specifications
- Max current
- 55 Amps per conductor at 30ºC
- Voltage rating
- 1000 V (WTTC), 600 V (TC-ER)
- Operating temperature
- -40°C to +105°C (UL: 90°C Dry, 75°C Wet; AWM 20328: 105°C)
- Bend radius (min.)
- Stationary: 6 in (150 mm); Installation: 9 in (230 mm); Flexing: 11 in (280 mm)
- Bulk cable weight
- 526 lbs/1000ft (783 kg/km)
- Conductor configuration
- 3+1 C (3 conductors, 1 ground wire), 8 AWG, 168x30 stranding, Bare Copper (BC)
- Inner jacket
- TPE - Thermoplastic Elastomer, nominal thickness 0.040 in (1.0 mm), nominal diameter 0.712 in (18.1 mm), Chrome color
- Insulation material & thickness
- PVC/Nylon - Polyvinyl Chloride + Nylon, nominal thickness 0.037 in (0.94 mm), nominal diameter 0.247 in (6.27 mm)
Characteristics (datasheet)
- Conductor configuration
- 3+1 C (3 conductors, 1 ground wire), 8 AWG, 168x30 stranding, Bare Copper (BC)
- Insulation material & thickness
- PVC/Nylon - Polyvinyl Chloride + Nylon, nominal thickness 0.037 in (0.94 mm), nominal diameter 0.247 in (6.27 mm)
- Outer shield
- Tinned Copper (TC) braid with 85% coverage
- Inner jacket
- TPE - Thermoplastic Elastomer, nominal thickness 0.040 in (1.0 mm), nominal diameter 0.712 in (18.1 mm), Chrome color
- Outer jacket
- TPE - Thermoplastic Elastomer, nominal thickness 0.085 in (2.2 mm), nominal diameter 0.87 in (22 mm)
- Overall cable diameter (nominal)
- 0.876 in (22.3 mm)
- Voltage rating
- 1000 V (WTTC), 600 V (TC-ER)
- Max current
- 55 Amps per conductor at 30ºC
- Nom. Conductor DCR
- 1 Ohm/1000ft (3.3 Ohm/km); Ground Wire: 1.08 Ohm/1000ft (3.54 Ohm/km); Outer Shield: 2.04 Ohm/1000ft (6.69 Ohm/km)
- Operating temperature
- -40°C to +105°C (UL: 90°C Dry, 75°C Wet; AWM 20328: 105°C)
- Bend radius (min.)
- Stationary: 6 in (150 mm); Installation: 9 in (230 mm); Flexing: 11 in (280 mm)
- Max. pull tension
- 1017 lbs (461.3 kg)
- Bulk cable weight
- 526 lbs/1000ft (783 kg/km)
7450WS Applications
- Robotics
- Robot
- Continuous Flex
Other Belden parts
- 7813LC — The Belden 7813LC is a Category 6 Premise Horizontal Cable with a 250 MHz bandwi...
- 26320FL — Belden 26320FL is an armored plenum-rated fire alarm cable (FPLP) with two 18 AW...
- 1116A — The Belden 1116A is a Type KX thermocouple cable featuring a single pair of 16 A...
- 934075188 — 1kV 32A Green/Yellow Cable Test Lead
- 83756 — The Belden 83756 is a high-temperature electronic cable consisting of six 14 AWG...
- 8163 — The Belden 8163 is a computer EIA RS-232/422 digital audio cable featuring 24 AW...
- 7047 — The Belden 7047 is a single-conductor hook-up wire with a 12 AWG tinned copper c...
- 1499A — The Belden 1499A is a multi-pair instrumentation and control cable consisting of...
More Bulk Wire Cable
- 78249 — The Belden 78249 is a high-performance 9-pair 20 AWG tinned copper cable with mo...
- 7408W — The 7408W is a MachFlex™ high-flex multi-conductor cable featuring 24 conductors...
- 5478C — The Belden 5478C is an 8-pair, 24 AWG tinned copper conductor communication and...
- 77025 — The Belden 77025 is a 9-conductor, 18 AWG tinned copper cable with mPPE insulati...
- 6398 — The Belden 6398 is an 18-pair, 28 AWG tinned copper multi-conductor communicatio...
- 86601CY — The 86601CY is an XTRAGUARD FLEX continuous flex data cable containing one pair...
- 9343 — The Belden 9343 is a high-performance instrumentation cable consisting of a sing...
- 78041 — The Belden 78041 is a multi-conductor ECOCABLE featuring 15 conductors of 22 AWG...
7450WS FAQ
What is 7450WS?
7450WS is a Bulk Wire Cable from Belden. The Belden 7450WS is a high-flexibility MachFlex™ cable designed for continuous flexing and robotics applications. It features a 3+1 conductor layout of 8 AWG bare copper wires insulated in PVC/Nylon, shielded by an 85% tinned copper braid, and jacketed with TPE inner and outer jackets. The cable is rated for 1000V WTTC and 600V TC-ER, with an operating temperature range of -40°C to +105°C.
Who manufactures 7450WS?
7450WS is manufactured by Belden.
Where can I download the 7450WS datasheet PDF?
The 7450WS datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 7450WS specifications
Click to ask a quick question:
Parameters
| Bend radius (min.) | Stationary: 6 in (150 mm); Installation: 9 in (230 mm); Flexing: 11 in (280 mm) |
| Bulk cable weight | 526 lbs/1000ft (783 kg/km) |
| Conductor configuration | 3+1 C (3 conductors, 1 ground wire), 8 AWG, 168x30 stranding, Bare Copper (BC) |
| Inner jacket | TPE - Thermoplastic Elastomer, nominal thickness 0.040 in (1.0 mm), nominal diameter 0.712 in (18.1 mm), Chrome color |
| Insulation material & thickness | PVC/Nylon - Polyvinyl Chloride + Nylon, nominal thickness 0.037 in (0.94 mm), nominal diameter 0.247 in (6.27 mm) |
| Max current | 55 Amps per conductor at 30ºC |
| Max. pull tension | 1017 lbs (461.3 kg) |
| Nom. Conductor DCR | 1 Ohm/1000ft (3.3 Ohm/km); Ground Wire: 1.08 Ohm/1000ft (3.54 Ohm/km); Outer Shield: 2.04 Ohm/1000ft (6.69 Ohm/km) |
| Operating temperature | -40°C to +105°C (UL: 90°C Dry, 75°C Wet; AWM 20328: 105°C) |
| Outer jacket | TPE - Thermoplastic Elastomer, nominal thickness 0.085 in (2.2 mm), nominal diameter 0.87 in (22 mm) |
| Outer shield | Tinned Copper (TC) braid with 85% coverage |
| Overall cable diameter (nominal) | 0.876 in (22.3 mm) |
| Voltage rating | 1000 V (WTTC), 600 V (TC-ER) |