The Belden 48140A is a 4-conductor, 10 AWG (7x18 stranded bare copper) UL Type TC power and control cable with PVC/nylon insulation, color-coded conductors, and a black PVC jacket with ripcord. It is rated 600 V UL, 90°C dry and wet, and is intended for power and control applications up to 600 V in indoor, outdoor, sunlight-resistant, UV-resistant, and direct-burial installations. The cable has a nominal overall diameter of 0.495 in (12.6 mm) and a maximum pull tension of 587.2 lbs (266.3 kg).

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

48140A Key Specifications

Max. Current
32 Amps per Conductor at 30ºC
UL Voltage Rating
600 V
Temperature Rating
90°C Dry, 90°C Wet; Wet/Dry: -30°C To 90°C
Bulk Cable Weight
196 lbs/1000ft
Conductors
4 conductors, 10 AWG, 7x18 stranding, BC - Bare Copper
Max. Pull Tension
587.2 lbs (266.3 kg)
Nom. Conductor DCR
1.04 Ohm/1000ft
Overall Cable Diameter (Nominal)
0.495 in (12.6 mm)

Characteristics (datasheet)

Conductors
4 conductors, 10 AWG, 7x18 stranding, BC - Bare Copper
UL Voltage Rating
600 V
Max. Current
32 Amps per Conductor at 30ºC
Nom. Conductor DCR
1.04 Ohm/1000ft
Temperature Rating
90°C Dry, 90°C Wet; Wet/Dry: -30°C To 90°C
Overall Cable Diameter (Nominal)
0.495 in (12.6 mm)
Max. Pull Tension
587.2 lbs (266.3 kg)
Bulk Cable Weight
196 lbs/1000ft

48140A Applications

  • Power and Control Applications up to 600V

Other Belden parts

  • 78405 — The Belden 78405 is an ECOCABLE featuring 20 conductors of 20 AWG tinned copper...
  • 1486A — The Belden 1486A is a 12-pair instrumentation and control cable featuring 16 AWG...
  • 6652 — The Belden 6652 is a 2-conductor 18 AWG tinned copper communication and control...
  • 29722C — The Belden 29722C is a 3-conductor VFD power cable built with 12 AWG (7x20) bare...
  • 2132A — The Belden 2132A is a 16-pair Fieldbus cable with 16 AWG tinned copper conductor...
  • 21639 — Belden 21639 is a CSA Tray Cable type TC-CIC rated 600 V, containing 41 conducto...
  • 58413 — The Belden 58413 is a plenum-rated, 3-pair 22 AWG bare copper communication and...
  • 74005 — The Belden 74005 is a 4-conductor, 22 AWG tinned copper industrial Ethernet cabl...

More Bulk Wire Cable

  • 6320 — The Belden 6320 is a 6-pair 24 AWG tinned copper communication and control cable...
  • 82841 — The Belden 82841 is a plenum-rated (CMP) RS-485 communication cable featuring on...
  • 82778 — The Belden 82778 is an audio, control, and instrument cable featuring 6 individu...
  • 70085LW — The Belden 70085LW is an 8 x quad snake cable constructed with 24 AWG bare coppe...
  • 1089A — The Belden 1089A is a 36-pair, 16 AWG bare copper instrumentation cable featurin...
  • 5507 — The Belden 5507 is a 7-conductor, 22 AWG tinned copper cable with PVC insulation...
  • 2134A — The Belden 2134A is a 600V TC-ER fieldbus cable featuring a 24-pair 16AWG tinned...
  • 80127 — The Belden 80127 (Alpha Wire P/N 80127) is an 18-conductor, 20 AWG tinned copper...

48140A FAQ

What is 48140A?

48140A is a Bulk Wire Cable from Belden. The Belden 48140A is a 4-conductor, 10 AWG (7x18 stranded bare copper) UL Type TC power and control cable with PVC/nylon insulation, color-coded conductors, and a black PVC jacket with ripcord. It is rated 600 V UL, 90°C dry and wet, and is intended for power and control applications up to 600 V in indoor, outdoor, sunlight-resistant, UV-resistant, and direct-burial installations. The cable has a nominal overall diameter of 0.495 in (12.6 mm) and a maximum pull tension of 587.2 lbs (266.3 kg).

Who manufactures 48140A?

48140A is manufactured by Belden.

Where can I download the 48140A datasheet PDF?

The 48140A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 48140A specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk Cable Weight196 lbs/1000ft
Conductors4 conductors, 10 AWG, 7x18 stranding, BC - Bare Copper
Max. Current32 Amps per Conductor at 30ºC
Max. Pull Tension587.2 lbs (266.3 kg)
Nom. Conductor DCR1.04 Ohm/1000ft
Overall Cable Diameter (Nominal)0.495 in (12.6 mm)
Temperature Rating90°C Dry, 90°C Wet; Wet/Dry: -30°C To 90°C
UL Voltage Rating600 V