6652 Datasheet
The Belden 6652 is a 2-conductor 18 AWG tinned copper communication and control cable with irradiated PVC insulation and a white PVC outer jacket. It is used for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable features a nominal characteristic impedance of 60 Ohm and is rated for a UL voltage of 150 V with an operating temperature range of -55°C to +80°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6652 Key Specifications
- Nom. Capacitance Cond-to-Cond
- 33 pF/ft (110 pF/m)
- Nom. Inductance
- 0.16 µH/ft (0.52 µH/m)
- UL Voltage Rating
- 150 V (AWM 2576)
- Operating Temperature
- -55°C To +80°C
- UL Temperature
- 80°C
- Conductor
- 2 Conductor 18 AWG (7x26) TC - Tinned Copper
- Nom. Characteristic Impedance
- 60 Ohm
- Overall Cable Diameter (Nominal)
- 0.203 in (5.16 mm)
6652 Marking Code (SMD Code)
Top marking: Alpha Wire -* P/N 6652 2C 18 AWG RU AWM 2576 VW-1 80C 150V CE ROHS
Characteristics (datasheet)
- Conductor
- 2 Conductor 18 AWG (7x26) TC - Tinned Copper
- Nom. Capacitance Cond-to-Cond
- 33 pF/ft (110 pF/m)
- Nom. Characteristic Impedance
- 60 Ohm
- Nom. Inductance
- 0.16 µH/ft (0.52 µH/m)
- UL Voltage Rating
- 150 V (AWM 2576)
- UL Temperature
- 80°C
- Operating Temperature
- -55°C To +80°C
- Overall Cable Diameter (Nominal)
- 0.203 in (5.16 mm)
6652 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 86218 — The Belden 86218 is an XTRAGUARD FLEX continuous flex data cable featuring 18 co...
- 2121A — The Belden 2121A is an 8-pair 18 AWG tinned copper fieldbus cable with XLPO insu...
- 35612 — The Belden 35612 is a 12 AWG stranded tinned copper lead wire with XLPO/XLPE the...
- 6302FC — The Belden 6302FC is a plenum-rated, shielded multi-conductor cable designed for...
- 27082A — The Belden 27082A is a UL Type TC (1277) power and control cable with four 14 AW...
- 7408W — The 7408W is a MachFlex™ high-flex multi-conductor cable featuring 24 conductors...
- 934059102 — Blue 60V 32A 250mm Test Probe Lead
- 7411W — The Belden 7411W is a high-flexibility 'MachFlex' cable featuring three 18AWG ba...
More Bulk Wire Cable
- 6321 — The Belden 6321 is a shielded, 7-pair communication and control cable constructe...
- 6165 — The Belden 6165 is a Teck90 1000V heavy-duty cable with four 2 AWG and one 6 AWG...
- 79843ELZ — The 79843ELZ is a 3-pair, 24 AWG stranded tinned copper conductor RS-485 cable w...
- 70065CH — The Belden 70065CH is a discontinued audio cable featuring four 26 AWG stranded...
- 5351C — The Belden 5351C is a 7-pair, 20 AWG tinned copper conductor shielded cable with...
- 5543 — The 5543 (Belden) is an XTRAGUARD 1 shielded multi-conductor cable featuring thr...
- 39118 — The Belden 39118 is an 18 AWG (16x30) tinned copper lead wire with PPO (polyphen...
- 9844 — The Belden 9844 is a 4-pair 24 AWG tinned copper cable with PE insulation and ov...
6652 FAQ
What is 6652?
6652 is a Bulk Wire Cable from Belden. The Belden 6652 is a 2-conductor 18 AWG tinned copper communication and control cable with irradiated PVC insulation and a white PVC outer jacket. It is used for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable features a nominal characteristic impedance of 60 Ohm and is rated for a UL voltage of 150 V with an operating temperature range of -55°C to +80°C.
Who manufactures 6652?
6652 is manufactured by Belden.
What is the marking code of 6652?
According to its datasheet, 6652 is marked "Alpha Wire -* P/N 6652 2C 18 AWG RU AWM 2576 VW-1 80C 150V CE ROHS".
Where can I download the 6652 datasheet PDF?
The 6652 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6652 specifications
Click to ask a quick question:
Parameters
| Conductor | 2 Conductor 18 AWG (7x26) TC - Tinned Copper |
| Nom. Capacitance Cond-to-Cond | 33 pF/ft (110 pF/m) |
| Nom. Characteristic Impedance | 60 Ohm |
| Nom. Inductance | 0.16 µH/ft (0.52 µH/m) |
| Operating Temperature | -55°C To +80°C |
| Overall Cable Diameter (Nominal) | 0.203 in (5.16 mm) |
| UL Temperature | 80°C |
| UL Voltage Rating | 150 V (AWM 2576) |