58413 Datasheet
The Belden 58413 is a plenum-rated, 3-pair 22 AWG bare copper communication and control cable featuring overall aluminum/polyester shielding and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and automation systems. The cable supports a UL voltage rating of 300 V (CMP) / 150 V (CL2P) and operates within a temperature range of -5°C to +75°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
58413 Key Specifications
- UL Voltage Rating
- 300 V (CMP), 150 V (CL2P)
- Operating temperature
- -5°C To +75°C (UL Temperature 75°C)
- Conductor size
- 3 Pair 22 AWG (7x30) BC - Bare Copper
- Insulation material
- PVC - Polyvinyl Chloride, Plenum Rated, Nom. Thickness 0.008 in (0.20 mm)
- Max. pull tension
- 14.9 lbs (6.76 kg)
- Min. bend radius (stationary)
- 2.1 in (53 mm)
- Nominal characteristic impedance
- 57 Ohm
- Outer jacket
- Slate PVC, Plenum Rated, Nom. Thickness 0.015 in (0.38 mm), Nom. Diameter 0.212 in (5.38 mm)
58413 Marking Code (SMD Code)
Top marking: Alpha Wire -* P/N 58413 3PR 22 AWG SHIELDED 75C CMP(UL) C(UL) OR 75C (UL) CL2P CE ROHS · package Slate PVC, Plenum Rated Outer Jacket, CL2P 75C, CMP 75C, CSA FT6, CSA C(UL) TYPE CMP
Characteristics (datasheet)
- Conductor size
- 3 Pair 22 AWG (7x30) BC - Bare Copper
- Insulation material
- PVC - Polyvinyl Chloride, Plenum Rated, Nom. Thickness 0.008 in (0.20 mm)
- Outer shield
- Bi-Laminate (Alum+Poly) Tape, 100% Coverage, 24 AWG (7x32) TC Drainwire
- Outer jacket
- Slate PVC, Plenum Rated, Nom. Thickness 0.015 in (0.38 mm), Nom. Diameter 0.212 in (5.38 mm)
- Nominal characteristic impedance
- 57 Ohm
- UL Voltage Rating
- 300 V (CMP), 150 V (CL2P)
- Operating temperature
- -5°C To +75°C (UL Temperature 75°C)
- Min. bend radius (stationary)
- 2.1 in (53 mm)
- Max. pull tension
- 14.9 lbs (6.76 kg)
58413 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 2177A — The Belden 2177A is a low-loss serial digital coaxial cable (RG-7 type) featurin...
- 1175A — The Belden 1175A is a shielded, single-pair cable designed for T1/DS1 central of...
- 65025 — The Belden 65025 is an XTRAGUARD FLEX flexible control cable with 25 stranded ba...
- 7125W — The Belden 7125W is a highly flexible MachFlex™ continuous flex cable featuring...
- 7931A — The Belden 7931A is an Industrial Ethernet Category 6 cable featuring 4 bonded p...
- 29552C — The Belden 29552C is a CSA Type TC VFD power cable built for variable frequency...
- 8422 — The Belden 8422 is a 2-conductor 22 AWG tinned copper microphone cable with poly...
- 58412 — The Belden 58412 is a plenum-rated, shielded communication and control cable fea...
More Bulk Wire Cable
- 29004 — Belden 29004 is a 600 V ACIC power and control cable containing three 16 AWG str...
- 55386 — The Belden 55386 is a high-performance 6-conductor, 18 AWG (7x26) tinned copper...
- 86606CY — The 86606CY is an XTRAGUARD FLEX continuous flex data cable featuring 6 pairs of...
- 86704CY — The Belden 86704CY is an XTRAGUARD FLEX continuous flex data cable featuring 4 p...
- 50978 — The Belden 50978 is a highly flexible, unshielded speaker cable with four 2.5 mm...
- 1813A — The Belden 1813A is a 2-conductor, 24 AWG stranded high-conductivity bare copper...
- 3232 — The Belden 3232 is a 3-conductor, 20 AWG tinned copper communication and control...
- 8458 — The Belden 8458 is a multi-conductor cable featuring 15 conductors of 22 AWG (7x...
58413 FAQ
What is 58413?
58413 is a Bulk Wire Cable from Belden. The Belden 58413 is a plenum-rated, 3-pair 22 AWG bare copper communication and control cable featuring overall aluminum/polyester shielding and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and automation systems. The cable supports a UL voltage rating of 300 V (CMP) / 150 V (CL2P) and operates within a temperature range of -5°C to +75°C.
Who manufactures 58413?
58413 is manufactured by Belden.
What is the marking code of 58413?
According to its datasheet, 58413 in Slate PVC, Plenum Rated Outer Jacket, CL2P 75C, CMP 75C, CSA FT6, CSA C(UL) TYPE CMP is marked "Alpha Wire -* P/N 58413 3PR 22 AWG SHIELDED 75C CMP(UL) C(UL) OR 75C (UL) CL2P CE ROHS".
Where can I download the 58413 datasheet PDF?
The 58413 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 58413 specifications
Click to ask a quick question:
Parameters
| Conductor size | 3 Pair 22 AWG (7x30) BC - Bare Copper |
| Insulation material | PVC - Polyvinyl Chloride, Plenum Rated, Nom. Thickness 0.008 in (0.20 mm) |
| Max. pull tension | 14.9 lbs (6.76 kg) |
| Min. bend radius (stationary) | 2.1 in (53 mm) |
| Nominal characteristic impedance | 57 Ohm |
| Operating temperature | -5°C To +75°C (UL Temperature 75°C) |
| Outer jacket | Slate PVC, Plenum Rated, Nom. Thickness 0.015 in (0.38 mm), Nom. Diameter 0.212 in (5.38 mm) |
| Outer shield | Bi-Laminate (Alum+Poly) Tape, 100% Coverage, 24 AWG (7x32) TC Drainwire |
| UL Voltage Rating | 300 V (CMP), 150 V (CL2P) |