Wire Cable Assemblies
1595
The Belden 1595 is a heavy-duty, single-conductor TW-75 rated cable designed for CEC power and control applications in wet or dry, indoor environments with sunlight resistance. It features a 1/0 AWG 19-strand bare copper conductor insulated with black PVC and has a voltage rating of 600 V. The cable is rated for a maximum current of 150 Amps per conductor at 30°C and supports operating temperatures from -25°C to +75°C.
1083A
The Belden 1083A is an UL-rated instrumentation cable featuring four 20 AWG triads and one 22 AWG comm wire, with PVC insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 300V (PLTC, CMG) and 150V (ITC) applications, offering robust shielding and a temperature range of -30°C to +105°C. This cable is designed for industrial control, raceways, digital instruments, RTDs, and distributed control systems (DCS).
2131A
The Belden 2131A is a 12-pair, 16 AWG tinned copper fieldbus cable with XLPE insulation, individual and overall Beldfoil shields, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, widely used in oil and gas extraction, petrochemical sites, and Profibus or Foundation FieldBus process automation. The cable is rated for 600V and operates in temperatures ranging from -40°C to 90°C.
5669
The Belden 5669 is a 6-conductor, 26 AWG tinned copper cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures between -35°C and +105°C. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, automation, and instrumentation systems. The cable meets multiple UL, CSA, and international flammability and environmental compliance standards, including FT4, CMG, VW-1, and RoHS.
83395
The Belden 83395 is a high-temperature, shielded multi-conductor cable featuring three 22 AWG tinned copper conductors with FEP insulation, a conductive textile and bi-laminate shield, and a flexible silicone rubber outer jacket. It is rated for 600 V (AWM 4516) and is designed to operate reliably in extreme high and low temperature environments (-70°C to +150°C). It is commonly used for low-voltage analog signals, low-voltage control, line-level audio, voice communications, and panel wiring in harsh environments.
1175A
The Belden 1175A is a shielded, single-pair cable designed for T1/DS1 central office, cross-connect, and interconnect applications. It features 22 AWG solid tinned copper conductors with polyethylene insulation, a Beldfoil shield with 100% coverage, and a PVC jacket. The cable has a nominal characteristic impedance of 100 Ohm, a UL voltage rating of 300 V, and is rated for indoor riser use (CMR/CMG).
1418B
The Belden 1418B is a CM-rated RGB video coaxial cable (Mini 59 / series 59) designed for indoor video transmission. It features 26 AWG stranded bare copper conductors with foam PE insulation, Duofoil and 95% tinned copper braid shielding, and dual PVC jackets. The cable has a characteristic impedance of 75 Ohm, a velocity of propagation of 78%, and is rated for 30 V RMS / 300 V RMS (CM) voltages.
1705
The Belden 1705 is a single-conductor communication and control cable designed for data, communication, audio, and low-level signal transmission. It features a 24 AWG tinned copper conductor with polyethylene insulation, an overall tinned copper shield, and a PVC outer jacket. This cable is rated for 1000 V and is suitable for industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
1851
The Belden 1851 is a single-conductor hook-up wire constructed with 30 AWG tinned copper strands and PVC insulation, rated for a voltage of 600 V. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and instrumentation systems. The product features a nominal diameter of 0.032 in, a minimum stationary bend radius of 0.3 in, and supports an operating temperature range from -55°C to +105°C.
79002
The Belden 79002 ECOFLEX is a highly flexible 3-conductor, 20 AWG tinned copper cable with mPPE insulation and a slate-colored mPPE outer jacket. It supports data, communication, audio, and low-level signal transmission, and is widely used in industrial networking, control panels, automation, and instrumentation. It is rated for 600V (AWM 21819) / 300V (AWM 21492) with an operating temperature range of -40°C to +105°C, offering low capacitance of 18.7 pF/ft and low inductance of 0.17 µH/ft.
83025
Belden 83025 is a high-temperature lead wire with a 22 AWG (7x30) silver-plated copper conductor and PTFE insulation. It is rated for 300 V RMS under UL AWM 1180 and 1000 V RMS under MIL-W-16878/5 Type EE, with a 200 °C UL temperature rating. It is intended for high-temperature inter-connection circuits and internal wiring of computer and electronic equipment.
86503CY
The 86503CY is a continuous flex data cable featuring 3 pairs of 26 AWG tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield with 85% tinned copper braid, and a slate PVC outer jacket. It is rated for a voltage of 300 V and supports an operating temperature range of -10°C to +105°C. This cable is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation equipment, and instrumentation systems.
89259
The Belden 89259 is a 75 Ohm analog video coaxial cable of RG-59 type, built with a 22 AWG bare copper conductor, FEP insulation, and a 95% bare copper braid shield with an FEP jacket. It is designed for standard analog video signal transmission in indoor, outdoor, and aerial environments, with a plenum CMP rating. The cable supports a wide operating temperature range from -70°C to +200°C and has a nominal overall diameter of 0.193 inches.
1713
The Belden 1713 is a 3-conductor, 20 AWG tinned copper communication and control cable with polyethylene insulation, an overall tinned copper braid shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, suitable for industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. It has a 600 V voltage rating and an operating temperature range of -20°C to +60°C.
1728
The Belden 1728 is a multi-conductor communication and control cable featuring 20 AWG stranded tinned copper conductors with polyethylene insulation, a tinned copper braid shield, and a slate PVC outer jacket. It is rated for a voltage of 600 V and operating temperatures between -20°C and +60°C. This cable is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation equipment, and instrumentation systems.
1749C
The Belden 1749C is a shielded 3-conductor, 16 AWG communication and control cable featuring tinned copper conductors, PVC insulation, and a slate PVC outer jacket. It is designed for industrial control systems, instrumentation, and analog or digital signal circuits, supporting a maximum voltage of 300 V and an operating temperature range of -20°C to +80°C. The cable includes a bare copper braid shield with 75% coverage to protect signal integrity.
1857
The Belden 1857 is a single-conductor, 18 AWG tinned copper hook-up wire with PVC insulation, rated for a maximum voltage of 600 V (MIL-SPEC). It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, automation equipment, and instrumentation systems. The wire operates within a temperature range of -55°C to +105°C and complies with military standard MIL-W-16878/1.
2112A
The Belden 2112A is an 8-pair 16AWG tinned copper fieldbus cable featuring XLPO insulation, individual and overall Beldfoil shielding, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, particularly in oil and gas extraction/refining, petrochemical, Profibus, and Foundation FieldBus process automation. It is built to withstand extreme temperatures, humidity, moisture, dust, oil exposure, and long-distance remote applications.
3073
The Belden 3073 is a single-conductor 20 AWG tinned copper hook-up wire with PVC insulation, rated for a voltage of 600 V. It is suitable for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The wire operates within a temperature range of -40°C to +105°C and complies with various standards such as AWM, MTW, and CSA.
4348ULV
The 4348ULV is a security and commercial audio cable composed of 12 pairs of 18 AWG stranded bare copper conductors with LSZH insulation and a LSZH outer jacket containing a ripcord. It is designed for use in intercom/PA systems, sound/audio systems, and control systems. The cable meets CPR Euroclass B2ca-s1,d1,a1 compliance and is rated for indoor and outdoor environmental suitability, including sunlight resistance.