The 4348ULV is a security and commercial audio cable composed of 12 pairs of 18 AWG stranded bare copper conductors with LSZH insulation and a LSZH outer jacket containing a ripcord. It is designed for use in intercom/PA systems, sound/audio systems, and control systems. The cable meets CPR Euroclass B2ca-s1,d1,a1 compliance and is rated for indoor and outdoor environmental suitability, including sunlight resistance.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

4348ULV Key Specifications

Nom. Capacitance Cond-to-Cond
100 pF/m (30 pF/ft)
Operating Temperature
-20°C To +70°C
Storage Temperature
-30°C to +70°C
Conductor
24 elements (12 pairs), 18 AWG, 7x26 stranding, BC - Bare Copper
CPR Euroclass Compliance
B2ca-s1,d1,a1
Insulation Material & Dimensions
LSZH - Low Smoke Zero Halogen (Flame Retardant), Nom. Thickness 0.26 mm (0.010 in), Nom. Insulation Diameter 1.72 mm (0.0677 in)
Max. Pull Tension
960 N (220 lbf)
Min. Installation Bend Radius
140 mm (5.5 in)

Characteristics (datasheet)

Conductor
24 elements (12 pairs), 18 AWG, 7x26 stranding, BC - Bare Copper
Insulation Material & Dimensions
LSZH - Low Smoke Zero Halogen (Flame Retardant), Nom. Thickness 0.26 mm (0.010 in), Nom. Insulation Diameter 1.72 mm (0.0677 in)
Outer Jacket Material & Dimensions
LSZH - Low Smoke Zero Halogen (Flame Retardant), Nom. Thickness 1.2 mm (0.047 in), Nom. Diameter 14 mm (0.55 in), Ripcord: Yes
Nom. Conductor DCR
21.3 Ohm/km (6.49 Ohm/1000ft)
Nom. Capacitance Cond-to-Cond
100 pF/m (30 pF/ft)
Operating Temperature
-20°C To +70°C
Storage Temperature
-30°C to +70°C
Max. Pull Tension
960 N (220 lbf)
Min. Installation Bend Radius
140 mm (5.5 in)
CPR Euroclass Compliance
B2ca-s1,d1,a1

4348ULV Applications

  • Intercom/PA Systems
  • Sound/Audio Systems
  • Control Systems

Other Belden parts

  • 6173 — The Belden 6173 is a heavy-duty Teck90 600V cable designed for CEC power and con...
  • 7201A — The Belden 7201A is a high-flex MachFlex™ shielded cable featuring two 24 AWG ba...
  • 6825 — The Belden 6825 is a single-conductor 18 AWG hook-up wire with a bare copper con...
  • 1515C — The Belden 1515C is a CM-rated audio snake cable featuring 20 pairs of 24 AWG ti...
  • 65418 — The Belden 65418 is an XTRAGUARD FLEX 18-conductor 14 AWG bare copper control ca...
  • 5938 — The Belden 5938 is a 2-pair, 28 AWG tinned copper cable with semi-rigid PVC insu...
  • 7807A — The Belden 7807A is a 50 Ohm wireless transmission coaxial cable of RG58 type, f...
  • 70060 — The Belden 70060 is a digital audio cable designed for professional studios, use...

More Bulk Wire Cable

  • 5471C — The 5471C is a communication and control cable featuring a single pair of 24 AWG...
  • 2126A — The Belden 2126A is a 50-pair, 18 AWG tinned copper fieldbus cable with cross-li...
  • 5129C — The Belden 5129C is a shielded, semi-rigid multi-pair cable consisting of 9 pair...
  • 2626 — The Belden 2626 is a single-conductor hook-up wire featuring a 26 AWG stranded n...
  • 5168C — The Belden 5168C is an XTRAGUARD 1 shielded cable featuring 8 conductors of 18 A...
  • 65834 — The Belden 65834 is a 34-conductor, 18 AWG bare copper flexible control cable wi...
  • 4402FE — The Belden 4402FE is a security and commercial audio cable featuring four 20 AWG...
  • 79055 — The 79055 is a 10-conductor, 24 AWG tinned copper cable with mPPE insulation and...

4348ULV FAQ

What is 4348ULV?

4348ULV is a Bulk Wire Cable from Belden. The 4348ULV is a security and commercial audio cable composed of 12 pairs of 18 AWG stranded bare copper conductors with LSZH insulation and a LSZH outer jacket containing a ripcord. It is designed for use in intercom/PA systems, sound/audio systems, and control systems. The cable meets CPR Euroclass B2ca-s1,d1,a1 compliance and is rated for indoor and outdoor environmental suitability, including sunlight resistance.

Who manufactures 4348ULV?

4348ULV is manufactured by Belden.

Where can I download the 4348ULV datasheet PDF?

The 4348ULV datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 4348ULV specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor24 elements (12 pairs), 18 AWG, 7x26 stranding, BC - Bare Copper
CPR Euroclass ComplianceB2ca-s1,d1,a1
Insulation Material & DimensionsLSZH - Low Smoke Zero Halogen (Flame Retardant), Nom. Thickness 0.26 mm (0.010 in), Nom. Insulation Diameter 1.72 mm (0.0677 in)
Max. Pull Tension960 N (220 lbf)
Min. Installation Bend Radius140 mm (5.5 in)
Nom. Capacitance Cond-to-Cond100 pF/m (30 pF/ft)
Nom. Conductor DCR21.3 Ohm/km (6.49 Ohm/1000ft)
Operating Temperature-20°C To +70°C
Outer Jacket Material & DimensionsLSZH - Low Smoke Zero Halogen (Flame Retardant), Nom. Thickness 1.2 mm (0.047 in), Nom. Diameter 14 mm (0.55 in), Ripcord: Yes
Storage Temperature-30°C to +70°C