5669 Datasheet

BeldenBulk Wire Cable

The Belden 5669 is a 6-conductor, 26 AWG tinned copper cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures between -35°C and +105°C. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, automation, and instrumentation systems. The cable meets multiple UL, CSA, and international flammability and environmental compliance standards, including FT4, CMG, VW-1, and RoHS.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

5669 Key Specifications

Nominal capacitance (conductor-to-conductor)
19.6 pF/ft (64.3 pF/m)
Nominal inductance
0.2 µH/ft (0.66 µH/m)
Voltage rating
300 V (CM, CMG, AWM 2464, AWM 2517)
Operating temperature
-35°C to +105°C (UL temperature: 105°C)
Conductor count / configuration
6 conductors, 26 AWG (7x34 tinned copper)
Maximum pull tension
17.9 lbs (8.12 kg)
Minimum bend radius (stationary)
1.9 in (48 mm)
Nominal overall cable diameter
0.186 in (4.72 mm)

Characteristics (datasheet)

Conductor count / configuration
6 conductors, 26 AWG (7x34 tinned copper)
Voltage rating
300 V (CM, CMG, AWM 2464, AWM 2517)
Operating temperature
-35°C to +105°C (UL temperature: 105°C)
Nominal capacitance (conductor-to-conductor)
19.6 pF/ft (64.3 pF/m)
Nominal inductance
0.2 µH/ft (0.66 µH/m)
Nominal overall cable diameter
0.186 in (4.72 mm)
Minimum bend radius (stationary)
1.9 in (48 mm)
Maximum pull tension
17.9 lbs (8.12 kg)

5669 Applications

  • Data, communication, audio, and low-level signal transmission
  • Industrial networking, serial communication, control panels, automation equipment, and instrumentation systems

Other Belden parts

  • 2202ELV — The Belden 2202ELV is a discontinued Category 6A horizontal and building backbon...
  • 79049 — The Belden 79049 is a multi-conductor ECOFLEX cable with 10 conductors of 22 AWG...
  • 934077101 — HIRSCHMANN TEST AND MEASUREMENT 934077101 Test Lead, 4mm Banana Plug to 4mm...
  • 79226 — The Belden 79226 is a high-flexibility 3-conductor 14 AWG tinned copper cable wi...
  • 1887ELV — The Belden 1887ELV is a Category 7 enhanced premise horizontal and building back...
  • 8877MN — The 8877MN is a SpaceMaker™ 7-conductor 20 AWG tinned copper cable with polyprop...
  • 3613 — The Belden 3613 is a Category 6+ premium premise horizontal cable (400 MHz) with...
  • 5170C — The 5170C is an XTRAGUARD 1 shielded cable featuring 10 conductors of 18 AWG tin...

More Bulk Wire Cable

  • 1860A — The Belden 1860A is an unshielded, plenum-rated speaker cable composed of two 12...
  • 77143 — The Belden 77143 is a 4-conductor 14 AWG tinned copper ECOCABLE with mPPE insula...
  • 83706 — The Belden 83706 is a high-temperature electronic cable consisting of six 16 AWG...
  • 1090A — The Belden 1090A is a 50-pair, 16 AWG bare copper instrumentation cable with PVC...
  • 45293 — Belden part 45293 is an XTRAGUARD 4 cable containing 3 pairs of 20 AWG (7x28) st...
  • 2256 — The Belden 2256 is a communication and control cable featuring two 20 AWG tinned...
  • 5364C — The Belden 5364C is a 4-conductor, 16 AWG tinned copper shielded cable with PVC...
  • 1424A — The Belden 1424A is a computer EIA RS-232/422 low-capacitance cable consisting o...

5669 FAQ

What is 5669?

5669 is a Bulk Wire Cable from Belden. The Belden 5669 is a 6-conductor, 26 AWG tinned copper cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures between -35°C and +105°C. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, automation, and instrumentation systems. The cable meets multiple UL, CSA, and international flammability and environmental compliance standards, including FT4, CMG, VW-1, and RoHS.

Who manufactures 5669?

5669 is manufactured by Belden.

Where can I download the 5669 datasheet PDF?

The 5669 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 5669 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor count / configuration6 conductors, 26 AWG (7x34 tinned copper)
Maximum pull tension17.9 lbs (8.12 kg)
Minimum bend radius (stationary)1.9 in (48 mm)
Nominal capacitance (conductor-to-conductor)19.6 pF/ft (64.3 pF/m)
Nominal inductance0.2 µH/ft (0.66 µH/m)
Nominal overall cable diameter0.186 in (4.72 mm)
Operating temperature-35°C to +105°C (UL temperature: 105°C)
Voltage rating300 V (CM, CMG, AWM 2464, AWM 2517)