The Belden 9618 is a computer EIA RS-232 cable featuring 37 stranded tinned copper conductors with semi-rigid PVC insulation, overall Beldfoil and tinned copper braid shielding, and a PVC jacket. It is designed for RS-232 applications, computer communications, low voltage analog and digital control, line level audio, and panel wiring. The cable has a nominal diameter of 0.411 in (10.4 mm), a UL voltage rating of 300 V (CMG), and supports an operating temperature range of -30°C to +80°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
9618 Key Specifications
- Max. Current
- 1 Amp per Conductor at 25ºC
- UL Voltage Rating
- 300 V (CMG), 300 V (UL AWM 2464)
- Operating temperature range
- -30°C to +80°C (UL Temperature: 80°C)
- Conductor configuration
- 37 conductors, 24 AWG 7x32 stranded tinned copper (TC)
- Insulation
- SR-PVC (Semi-Rigid Polyvinyl Chloride), nominal thickness 0.011 in (0.28 mm), nominal diameter 0.044 in (1.1 mm)
- Nom. Conductor DCR
- 25 Ohm/1000ft
- Nominal overall cable diameter
- 0.411 in (10.4 mm)
- Nom Outer Shield DCR
- 4.4 Ohm/1000ft (14 Ohm/km)
Characteristics (datasheet)
- Conductor configuration
- 37 conductors, 24 AWG 7x32 stranded tinned copper (TC)
- Insulation
- SR-PVC (Semi-Rigid Polyvinyl Chloride), nominal thickness 0.011 in (0.28 mm), nominal diameter 0.044 in (1.1 mm)
- Shielding
- Bi-Laminate (Alum+Poly) tape 100% coverage + tinned copper braid 65% coverage
- Outer jacket
- PVC - Polyvinyl Chloride, nominal thickness 0.040 in (1.0 mm), nominal diameter 0.411 in (10.4 mm)
- Nominal overall cable diameter
- 0.411 in (10.4 mm)
- Nom. Conductor DCR
- 25 Ohm/1000ft
- Nom Outer Shield DCR
- 4.4 Ohm/1000ft (14 Ohm/km)
- Max. Current
- 1 Amp per Conductor at 25ºC
- UL Voltage Rating
- 300 V (CMG), 300 V (UL AWM 2464)
- Operating temperature range
- -30°C to +80°C (UL Temperature: 80°C)
9618 Applications
- RS-232 applications
- Computer Communications
- Low Voltage Analog signals (4-20ma, 0-10v, ...)
- Low Voltage Digital control (24v, …)
- Line Level Audio
- Panel Wiring
Other Belden parts
- 1321SB — The Belden 1321SB is a dual-conductor (#16-2c) fire alarm cable featuring solid...
- 45162 — Belden part 45162 is a 2-conductor 18 AWG (16x30 stranded tinned copper) XTRAGUA...
- 3233 — The Belden 3233 is a multi-conductor communication and control cable featuring 4...
- 74004 — The Belden 74004 is a high-performance, zero-halogen industrial Ethernet cable (...
- 8918 — The Belden 8918 is a low-temperature plastic lead wire with an 18 AWG tinned cop...
- 5470C — The Belden 5470C is a 10-conductor, 20 AWG tinned copper shielded cable with PVC...
- 9641 — The Belden 9641 is a computer EIA RS-488 cable featuring 26 AWG and 24 AWG stran...
- 79005 — ECOFLEX part 79005 is a 7-conductor 20 AWG tinned copper cable with mPPE insulat...
More Bulk Wire Cable
- 8880MN — The Belden 8880MN is a SpaceMaker™ 12-conductor cable featuring 20 AWG tinned co...
- 29008 — Belden part 29008 is a TC-ACIC Canadian instrumentation cable rated for 600 V po...
- 2463C — The Belden 2463C is a shielded communication and control cable featuring 4 pairs...
- 6144 — The Belden 6144 is a Teck90 1000V industrial cable featuring three 1/0 AWG bare...
- 24501D — Belden 24501D is a Canadian TC-ACIC 600 V instrumentation cable with one 16 AWG...
- 1073A — The Belden 1073A is a UL-listed instrumentation cable featuring 16 pairs of 16 A...
- 1888ELV — The 1888ELV is a Category 7A Enhanced Premise Horizontal Cable (1300MHz) with 4...
- 28335A — The Belden 28335A is a 5-conductor, 18 AWG (7x26) bare copper power and control...
9618 FAQ
What is 9618?
9618 is a Bulk Wire Cable from Belden. The Belden 9618 is a computer EIA RS-232 cable featuring 37 stranded tinned copper conductors with semi-rigid PVC insulation, overall Beldfoil and tinned copper braid shielding, and a PVC jacket. It is designed for RS-232 applications, computer communications, low voltage analog and digital control, line level audio, and panel wiring. The cable has a nominal diameter of 0.411 in (10.4 mm), a UL voltage rating of 300 V (CMG), and supports an operating temperature range of -30°C to +80°C.
Who manufactures 9618?
9618 is manufactured by Belden.
Where can I download the 9618 datasheet PDF?
The 9618 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 9618 specifications
Click to ask a quick question:
Parameters
| Conductor configuration | 37 conductors, 24 AWG 7x32 stranded tinned copper (TC) |
| Insulation | SR-PVC (Semi-Rigid Polyvinyl Chloride), nominal thickness 0.011 in (0.28 mm), nominal diameter 0.044 in (1.1 mm) |
| Max. Current | 1 Amp per Conductor at 25ºC |
| Nom. Conductor DCR | 25 Ohm/1000ft |
| Nominal overall cable diameter | 0.411 in (10.4 mm) |
| Nom Outer Shield DCR | 4.4 Ohm/1000ft (14 Ohm/km) |
| Operating temperature range | -30°C to +80°C (UL Temperature: 80°C) |
| Outer jacket | PVC - Polyvinyl Chloride, nominal thickness 0.040 in (1.0 mm), nominal diameter 0.411 in (10.4 mm) |
| Shielding | Bi-Laminate (Alum+Poly) tape 100% coverage + tinned copper braid 65% coverage |
| UL Voltage Rating | 300 V (CMG), 300 V (UL AWM 2464) |