1073A Datasheet
The Belden 1073A is a UL-listed instrumentation cable featuring 16 pairs of 16 AWG stranded bare copper conductors with PVC-nylon insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF use, with an operating temperature range of 90°C dry and wet. This cable is suitable for industrial and digital control systems, instruments, encoders, solenoids, valves, actuators, and distributed control systems (DCS) / programmable logic controllers (PLC).
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1073A Key Specifications
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Operating Temperature
- 90°C Dry, 90°C Wet, -30C to 90C Dry, 75C wet
- Bulk Cable Weight
- 510.3 lbs/1000ft
- Conductor
- 16 AWG 7x24 BC - Bare Copper (16 pairs)
- Max. Pull Tension
- 1178 lbs (534.3 kg)
- Nom. Conductor DCR
- 3.67 Ohm/1000ft (12.0 Ohm/km)
- Nom Outer Shield DCR
- 2.84 Ohm/1000ft (9.32 Ohm/km)
- Overall Cable Diameter (Nominal)
- 0.928 in (23.6 mm)
Characteristics (datasheet)
- Conductor
- 16 AWG 7x24 BC - Bare Copper (16 pairs)
- Nom. Conductor DCR
- 3.67 Ohm/1000ft (12.0 Ohm/km)
- Nom Outer Shield DCR
- 2.84 Ohm/1000ft (9.32 Ohm/km)
- Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Operating Temperature
- 90°C Dry, 90°C Wet, -30C to 90C Dry, 75C wet
- Overall Cable Diameter (Nominal)
- 0.928 in (23.6 mm)
- Max. Pull Tension
- 1178 lbs (534.3 kg)
- Bulk Cable Weight
- 510.3 lbs/1000ft
1073A Applications
- Industrial Control
- Raceways, Cable trays and ducts
- Digital Control
- Instruments (4-20ma, 0-10v)
- Low voltage digital control (24v)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids, Valves, Actuators, Positioners
Other Belden parts
- 1040A — The Belden 1040A is a UL-listed instrumentation cable consisting of 6 pairs of 1...
- 5350C — The Belden 5350C is a 5-pair, 20 AWG tinned copper conductor shielded cable with...
- 30801 — Belden part 30801 is a 1 AWG lead wire built with 210x24 stranded tinned copper,...
- 85164 — The Belden 85164 is a high-temperature shielded electronic cable featuring four...
- 1331A — The Belden 1331A is a 16-pair 18AWG tinned copper fieldbus cable with polypropyl...
- 7400W — The Belden 7400W is a MachFlex™ high-flexibility cable designed for continuous f...
- 78309 — The Belden 78309 is a shielded, 9-pair, 28 AWG tinned copper cable with modified...
- 1306 — The Belden 1306 is a RW90 1000V, 2/0 AWG bare copper cable with XLPE insulation,...
More Bulk Wire Cable
- 8814 — The Belden 8814 is an unshielded, 2-conductor 14 AWG speaker cable with bare cop...
- 9265 — The Belden 9265 is a composite cable designed for ENG, EFP, and CCTV application...
- 7418W — The Belden 7418W is a high-flexibility multi-conductor cable (MachFlex™) designe...
- 9397 — The Belden 9397 is a 2-conductor 24 AWG stranded high-conductivity bare copper m...
- 5272C — The Belden 5272C is an XTRAGUARD 1 shielded cable featuring two pairs of 24 AWG...
- 5561C — The Belden 5561C (Alpha Wire) is a XTRAGUARD 1 shielded multi-conductor cable fe...
- 79116 — The Belden 79116 is a 2-conductor, 16 AWG stranded tinned copper cable with modi...
- 65404 — The Belden 65404 is an XTRAGUARD FLEX flexible control cable featuring four 14 A...
1073A FAQ
What is 1073A?
1073A is a Bulk Wire Cable from Belden. The Belden 1073A is a UL-listed instrumentation cable featuring 16 pairs of 16 AWG stranded bare copper conductors with PVC-nylon insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for 600V TC-ER and 150V NPLF use, with an operating temperature range of 90°C dry and wet. This cable is suitable for industrial and digital control systems, instruments, encoders, solenoids, valves, actuators, and distributed control systems (DCS) / programmable logic controllers (PLC).
Who manufactures 1073A?
1073A is manufactured by Belden.
Where can I download the 1073A datasheet PDF?
The 1073A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1073A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 510.3 lbs/1000ft |
| Conductor | 16 AWG 7x24 BC - Bare Copper (16 pairs) |
| Max. Pull Tension | 1178 lbs (534.3 kg) |
| Nom. Conductor DCR | 3.67 Ohm/1000ft (12.0 Ohm/km) |
| Nom Outer Shield DCR | 2.84 Ohm/1000ft (9.32 Ohm/km) |
| Operating Temperature | 90°C Dry, 90°C Wet, -30C to 90C Dry, 75C wet |
| Overall Cable Diameter (Nominal) | 0.928 in (23.6 mm) |
| Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |