21668 Datasheet
Belden part 21668 is a CSA TC-CIC 600 V tray cable with two 1/0 AWG stranded bare copper conductors plus one 6 AWG bare copper ground, XLPE insulation, and a black PVC outer jacket rated 90 °C dry/wet. It is intended for CEC power and control applications and is rated for direct burial, indoor, and outdoor use with FT4 flammability performance. The cable has a nominal diameter of 1.180 in (29.97 mm), includes a ripcord, and weighs 1038 lbs/1000 ft (1545 kg/km).
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
21668 Key Specifications
- Voltage Rating
- 600 V (UL); 600 V (CSA TC)
- Temperature Rating
- 90 °C Dry, 90 °C Wet; Operating Wet/Dry: -40 °C to 90 °C
- Bulk Cable Weight
- 1038 lbs/1000ft (1545 kg/km)
- Conductor DCR
- 1.6 Ohm/1000ft (5.2 Ohm/km)
- Conductors
- 2 x 1/0 AWG (19x12.5) bare copper + 1 x 6 AWG (7x14) bare copper ground
- Insulation
- XLPE/XLPO/XLP (Thermoset), 0.040 in nominal thickness, 0.360 in (9.14 mm) nominal diameter
- Jacket
- Black PVC, 0.095 in (2.4 mm) nominal thickness, ripcord: Yes
- Nominal Cable Diameter
- 1.180 in (29.97 mm)
Characteristics (datasheet)
- Voltage Rating
- 600 V (UL); 600 V (CSA TC)
- Temperature Rating
- 90 °C Dry, 90 °C Wet; Operating Wet/Dry: -40 °C to 90 °C
- Conductors
- 2 x 1/0 AWG (19x12.5) bare copper + 1 x 6 AWG (7x14) bare copper ground
- Insulation
- XLPE/XLPO/XLP (Thermoset), 0.040 in nominal thickness, 0.360 in (9.14 mm) nominal diameter
- Jacket
- Black PVC, 0.095 in (2.4 mm) nominal thickness, ripcord: Yes
- Nominal Cable Diameter
- 1.180 in (29.97 mm)
- Conductor DCR
- 1.6 Ohm/1000ft (5.2 Ohm/km)
- Bulk Cable Weight
- 1038 lbs/1000ft (1545 kg/km)
21668 Applications
- CEC Power and Control Applications
Other Belden parts
- 5026C — The Belden 5026C (branded as Alpha Wire) is a multi-conductor instrumentation ca...
- 6281MD — The Belden 6281MD is a plenum-rated OSDP reader cable designed for access contro...
- 25103 — Belden 25103 is an XTRAGUARD 2 cable with 3 conductors of 22 AWG (7/30) tinned c...
- 79013 — The Belden 79013 is a flexible 5-conductor 18 AWG tinned copper cable with mPPE...
- 9538 — The Belden 9538 is a computer EIA RS-232 cable featuring eight 24 AWG stranded t...
- 1087A — The Belden 1087A is a 36-pair, 18 AWG bare copper instrumentation cable featurin...
- 6502FC — The Belden 6502FC is a plenum-rated multi-conductor cable designed for security,...
- 58802 — The Belden 58802 is a shielded communication and control cable featuring two pai...
More Bulk Wire Cable
- 85224CY — The Belden 85224CY is a four-conductor, 22 AWG bare copper XTRAGUARD FLEX contin...
- 78109 — The Belden 78109 is a multi-conductor ECOCABLE consisting of 9 pairs of 28 AWG s...
- 9506 — The Belden 9506 is a computer EIA RS-232 cable featuring 6 twisted pairs of 24 A...
- 5313C — The Belden 5313C is a 15-conductor, 22 AWG tinned copper XTRAGUARD 1 shielded ca...
- 9618 — The Belden 9618 is a computer EIA RS-232 cable featuring 37 stranded tinned copp...
- 86212 — The Belden 86212 is a 12-conductor, 24 AWG stranded tinned copper XTRAGUARD FLEX...
- 80052 — The Belden 80052 (ECOFLEX PUR) is a 3-conductor, 14 AWG tinned copper cable with...
- 86706CY — The 86706CY is a continuous flex data cable featuring six pairs of 22 AWG tinned...
21668 FAQ
What is 21668?
21668 is a Bulk Wire Cable from Belden. Belden part 21668 is a CSA TC-CIC 600 V tray cable with two 1/0 AWG stranded bare copper conductors plus one 6 AWG bare copper ground, XLPE insulation, and a black PVC outer jacket rated 90 °C dry/wet. It is intended for CEC power and control applications and is rated for direct burial, indoor, and outdoor use with FT4 flammability performance. The cable has a nominal diameter of 1.180 in (29.97 mm), includes a ripcord, and weighs 1038 lbs/1000 ft (1545 kg/km).
Who manufactures 21668?
21668 is manufactured by Belden.
Where can I download the 21668 datasheet PDF?
The 21668 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 21668 specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 1038 lbs/1000ft (1545 kg/km) |
| Conductor DCR | 1.6 Ohm/1000ft (5.2 Ohm/km) |
| Conductors | 2 x 1/0 AWG (19x12.5) bare copper + 1 x 6 AWG (7x14) bare copper ground |
| Insulation | XLPE/XLPO/XLP (Thermoset), 0.040 in nominal thickness, 0.360 in (9.14 mm) nominal diameter |
| Jacket | Black PVC, 0.095 in (2.4 mm) nominal thickness, ripcord: Yes |
| Nominal Cable Diameter | 1.180 in (29.97 mm) |
| Temperature Rating | 90 °C Dry, 90 °C Wet; Operating Wet/Dry: -40 °C to 90 °C |
| Voltage Rating | 600 V (UL); 600 V (CSA TC) |